SQUARE D

safety module, Modicon TM3, 1 function, Cat 4 PL e, SIL CL3, spring, 24V DC

MODULE TM3 SAFETY ESTOP, CAT.

SQDTM3SAF5RG TM3SAF5RG 3606485393001
453.47 / EA
http://schema.org/OutOfStock
  • Country of Origin: France
  • Depth: 73 mm
  • Height: 94 mm
  • Net Weight: 0.19 kg
  • Output Voltage: 10 V
  • Weight: 0.19 kg
  • Width: 43.7 mm
This TM3 safety expansion module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of PL e/Category 4 conforming to EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 62061. It has a module locking latch, 2 TM3 bus connectors designed to provide continuity of the link between connected modules, a symmetrical rail locking clip, display block for the module channels and diagnostics. It completes your Modicon M221, M241 or M251 PLC configuration with a dedicated safety I/O, without the need to use a complete safety controller. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It has spring terminals for fast and reliable wiring of safety circuits.
QTY
  • Product Description
  • Features
  • Specifications
This TM3 safety expansion module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of PL e/Category 4 conforming to EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 62061. It has a module locking latch, 2 TM3 bus connectors designed to provide continuity of the link between connected modules, a symmetrical rail locking clip, display block for the module channels and diagnostics. It completes your Modicon M221, M241 or M251 PLC configuration with a dedicated safety I/O, without the need to use a complete safety controller. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It has spring terminals for fast and reliable wiring of safety circuits.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary
    • Product Certifications : ANSI Haz Loc Class 1 Division 2 (pending) || UL 61010-2-201 || EAC || TÜV || RCM || CSA Haz Loc Class 1 Division 2 (pending) || CSA 61010-2-201 (pending)
    • Output Voltage : 10 V relay output
    • Power Consumption In W : 0.2 W 5 V DC || 3.6 W 24 V DC
    • [Uc] Control Circuit Voltage : 24 V DC
    • Height : 94 mm
    • Standards : ISO 13849-1:2008 || ISO 13849-2:2012 || IEC 62061:2005 || IEC 61508:2010 || IEC 60947-5-1:2010 || IEC 61131-2:2007 || IEC 60204-1:2005 || IEC 60204-1:2009/A1 || IEC 61010-1:2010 || EN 50581:2012
    • Output Thermal Current : 6 A per relay relay output
    • Connections - Terminals : captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34 || captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34 || captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34 || captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34 || captive spring terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34 || captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals || captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals || captive spring terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals || captive spring terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals
    • Electromagnetic Compatibility : electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2 || electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2 || susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz to 1 GHz) conforming to IEC 61000-4-3 || susceptibility to electromagnetic fields - test level: 3 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3 || susceptibility to electromagnetic fields - test level: 1 V/m (2 GHz...3 GHz) conforming to IEC 61000-4-3 || magnetic field at power frequency - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8 || electrical fast transient/burst immunity test - test level: 3 kV (power lines (DC)) conforming to IEC 61000-4-4 || electrical fast transient/burst immunity test - test level: 2 kV (I/O) conforming to IEC 61000-4-4 || 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to IEC 61000-4-5 || conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6 || radiated emission - test level: 40 dBµV/m class A (24 V) conforming to IEC 55011 || radiated emission - test level: 47 dBµV/m class A (24 V) conforming to IEC 55011
    • Minimum Output Current : 10 mA relay output
    • Marking : EFUP 10 || CE || UL || EAC || RCM || CSA || TÜV
    • [Ith] Conventional Free Air Thermal Current : 18 A
    • Associated Fuse Rating : 4 A gG or gL relay output IEC 60947-5-1 || 6 A fast blow relay output IEC 60947-5-1
    • [Uimp] Rated Impulse Withstand Voltage : 4 kV III IEC 60647-5-1
    • Net Weight : 0.19 kg
    • Current Consumption : 100 mA 24 V DC external supply
    • Output Type : relay instantaneous opening, 3 NO, potential free
    • [Us] Rated Supply Voltage : 24 V - 15...20 % DC
    • [Ui] Rated Insulation Voltage : 300 V 2)IEC 60647-5-1
    • Mounting Support : top hat type TH35-7.5 rail IEC 60715 || top hat type TH35-15 rail IEC 60715 || wall mount using attached fasteners
    • Local Signalling : 8 LEDs (green/red) for user
    • Maximum Switching Voltage : 230 V AC-15 50 Hz relay instantaneous opening) || 24 V DC-13 relay instantaneous opening)
    • Electrical Connection : spring terminal
    • Safety Reliability Data : DC = 95 % ISO 13849-1 || PFHd = 5E-9 1/h IEC 61508-1 1 operation/hour DC-13 24 V DC, <4 A || PFHd = 30E-9 1/h IEC 61508-1 60 operations/hour DC-13 24 V DC, <1 A || MTTFd = 500 years ISO 13849-1 1 operation/hour DC-13 24 V DC, <4 A || MTTFd = 85 years ISO 13849-1 60 operations/hour DC-13 24 V DC, <1 A || SFF = 95 % IEC 61508-1 || HFT = 1 IEC 61508-1 || type = A IEC 61508-1
    • Input Protection Type : internal, electronic
    • Width : 43.7 mm
    • Number Of Safety Circuits : 3 NO relay instantaneous opening
    • Depth : 73 mm
    • Synchronisation Time Between Inputs : unlimited
    • Maximum Cable Distance Between Devices : 30 m
    • Maximum Response Time On Input Open : 40 ms
    • Breaking Capacity : 360 VA holding AC-15 B300 relay output || 3600 VA inrush AC-15 B300 relay output
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP1403010EN
    • Packaging Without Single Use Plastic : No
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Scip Number : 99cae485-192a-4a91-bc99-8cce8f6405e4
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Circularity Profile : ENVEOLI1403010EN
    • Take-Back : No
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 154.51
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 3.4466392294
    • Carbon Footprint Of The Distribution Phase [A4] : 0 kg CO2 eq.
    • Pvc Free : Yes
    • Carbon Footprint Of The Installation Phase [A5] : 0 kg CO2 eq.
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 158 kg CO2 eq.
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
    • Carbon Footprint Of The End-Of-Life Phase [C1 To C4] : 0.1396418564
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 158.12700492
  • Environment
    • Resistance To Conducted Disturbances : 10 V 0.15...80 MHz IEC 61000-4-6
    • Resistance To Electromagnetic Fields : 10 V/m 80 MHz...1 GHz IEC 61000-4-3 || 3 V/m 1.4 GHz...2 GHz IEC 61000-4-3 || 1 V/m 2 GHz...3 GHz IEC 61000-4-3
    • Standards : ISO 13850 || IEC 60947-5-1 || EN 1088/ISO 14119 || IEC 60204-1 || IEC 60947-1
    • Ambient Air Temperature For Operation : -10-55 °C horizontal installation
    • Storage Altitude : 0-3000 m
    • Pollution Degree : 2
    • Ip Degree Of Protection : IP20 terminals)IEC 60529
    • Shock Resistance : 15 gn 11 ms IEC 60068-2-27
    • Resistance To Magnetic Fields : 30 A/m 50/60 Hz IEC 61000-4-8
    • Vibration Resistance : +/- 3.5 mm (f= 5-150 Hz) conforming to IEC 60068-2-6
    • Ambient Air Temperature For Storage : -25-70 °C
    • Relative Humidity : 10-95 %, without condensation in operation) || 10-95 %, without condensation in storage)
    • Surge Withstand : 1 kV power lines (DC) differential mode IEC 61000-4-5 DC || 1 kV power lines (DC) common mode IEC 61000-4-5 DC
    • Resistance To Electrostatic Discharge : 8 kV in air IEC 61000-4-2 || 6 kV on contact IEC 61000-4-2
    • Mechanical Robustness : bumps 6 ms 300 shocks 25 gn) IEC 60068-2-27
    • Operating Altitude : 0...6561.68 ft (0...2000 m)
    • Resistance To Fast Transients : 3 kV power lines (DC) DC)IEC 61000-4-4 || 2 kV I/O linesIEC 61000-4-4
    • Electromagnetic Emission : radiated emissions 50 dBµV/m class A 24 V DC)30-230 Hz IEC 61131-3 || radiated emissions 57 dBµV/m class A 24 V DC)230-1000 Hz IEC 61131-3
  • Specifications
    • Country of Origin : France
    • Width : 43.7 mm
    • Height : 94 mm
    • Weight : 0.19 kg
    • Range Of Product : Modicon TM3 Safety
    • Product Or Component Type : safety module
    • Safety Module Application : for emergency stop and switch monitoring
    • Function Of Module : emergency stop monitoring 1-channel wiring || emergency stop monitoring 2-channel wiring || monitoring of a movable guard with 2 switches and automatic start
    • Device Short Name : TM3SAF
    • Safety Level : can reach PL e/category 4 ISO 13849-1 2008 || can reach PL e/category 4 ISO 13849-2 2012 || can reach SILCL 3 IEC 62061 2005 || can reach SIL 3 IEC 61508 2010