SQUARE D

Motor starter, TeSys island, 40A at AC-1, 38A at AC-3, 18.5kW, 20hp, DOL type

TESYS ISLAND STARTER 25HP

SQDTPRST038 TPRST038 3606489832766
534.98 / EA
http://schema.org/OutOfStock
  • Country of Origin: France
  • Depth: 115 mm
  • Height: 121 mm
  • Net Weight: 0.718 kg
  • Warranty Length: 18 mth
  • Weight: 0.718 kg
  • Width: 45 mm
TeSys island direct starter, 3 poles, 38A/690V. Connected to a TPRBC bus coupler it controls, protects and monitors loads up to 38A and motors up to 18,5kW@400V / 20hp@480V. It provides motor protection functions including thermal overload (setting 0.76-38A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of switching cycles, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC).
QTY
  • Product Description
  • Specifications
TeSys island direct starter, 3 poles, 38A/690V. Connected to a TPRBC bus coupler it controls, protects and monitors loads up to 38A and motors up to 18,5kW@400V / 20hp@480V. It provides motor protection functions including thermal overload (setting 0.76-38A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of switching cycles, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC).
  • Environment
    • Ambient Air Temperature For Operation : -10-50 °C without derating || 50-60 °C with current derating
    • Shock Resistance : 15 gn 11 ms) IEC 60068-2-27
    • Vibration Resistance : 1.5 mm peak to peak 3-13 Hz) IEC 60068-2-6 || 1 gn 13-200 Hz) IEC 60068-2-6
    • Electromagnetic Compatibility : electrostatic discharge immunity test, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || radiated RF field immunity test, level 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transient immunity test, level 4, 4 kV, conforming to EN/IEC 61000-4-4 || surge immunity test (differential mode), level 3, 2 kV, conforming to EN/IEC 61000-4-5 || surge immunity test (common mode), level 4, 4 kV, conforming to EN/IEC 61000-4-5 || conducted RF disturbance immunity test, 20 V, conforming to EN/IEC 61000-4-6
    • Pollution Degree : 2
    • Ambient Air Temperature For Storage : -25-70 °C
    • Protective Treatment : TC
    • Relative Humidity : 5-95 %
    • Ip Degree Of Protection : IP20
    • Operating Altitude : 0...6561.68 ft (0...2000 m) without derating
    • Fire Resistance : 960 °C UL 94 || 850 °C IEC 60695-2-1 || 650 °C IEC 60695-2-12
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Mercury Free : Yes
    • Halogen Content Performance : Halogen free plastic parts product
    • Packaging Without Single Use Plastic : Yes
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Scip Number : 0bda50ae-711f-4024-bff6-ce0577049f63
    • Circularity Profile : ENVEOLI1904009EN
    • Take-Back : No
    • Sustainable Packaging : Yes
    • Eu Rohs Directive : Compliant with Exemptions
  • Complementary
    • Mounting Mode : horizontal and vertical 35 mm symmetrical DIN rail)
    • Height : 121 mm
    • Product Certifications : CCC || EAC || UL || CSA
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Standards : EN/IEC 60947-1 || EN/IEC 60947-4-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1
    • Connections - Terminals : screw-clamp terminals 1 1.5-10 mm² AWG 16...AWG 8)rigid || screw-clamp terminals 2 1.5-10 mm² AWG 16...AWG 8)rigid || screw-clamp terminals 1 2.5-10 mm² AWG 14...AWG 8)flexible without cable end || screw-clamp terminals 2 2.5-10 mm² AWG 14...AWG 8)flexible without cable end || screw-clamp terminals 1 1.5-10 mm² AWG 16...AWG 10)flexible with cable end || screw-clamp terminals 2 1.5-6 mm² AWG 16...AWG 10)flexible with cable end
    • Net Weight : 0.718 kg
    • Metering Type : time device ON || time device switch ON || number of faults || number of switching cycles || number of device power cycles || average current Iavg || average voltage Vavg || max current Imax || max voltage Vmax || active and reactive power with voltage module || active and reactive energy with voltage module || true power factor with voltage module
    • Maximum Operating Rate : 3600 cyc/mn AC-3
    • Local Signalling : 1 LED (green/red) for DS (device status) || 1 LED (green/red) for LS (load status)
    • Electrical Durability : 1.4 Mcycles 38 A AC-3 440 V || 2 Mcycles 40 A AC-1 440 V
    • Mechanical Durability : 30 Mcycles
    • Operating Time : < 100 ms closing || < 30 ms opening
    • Width : 45 mm
    • Depth : 115 mm
    • Tightening Torque : 2.5-2.5 N.m flat Ø 6 mm || 2.5-2.5 N.m Philips No 3
    • Protection Type : thermal overload protection || motor overheat || overcurrent || undercurrent || jam || long start || stall || rapid cycle lockout || phase sequence || rapid restart lockout || phase loss || phase reversal || phase unbalance || ground current
  • Specifications
    • Country of Origin : France
    • Width : 45 mm
    • Height : 121 mm
    • Weight : 0.718 kg
    • Current Consumption : 160 mA contactor sealed || 160 mA contactor closing
    • Power Dissipation In W : 11.8 W at Ie AC-3
    • Power Dissipation Per Pole : 2.9 W AC-3 - Ith 38 A || 3.2 W AC-1 - Ith 40 A
    • Average Impedance : 2 mOhm - Ith 40 A 50 Hz
    • Reset : remotely or automatically
    • [Ith] Conventional Free Air Thermal Current : 40 A (at 50 °C)
    • [Uc] Control Circuit Voltage : 24 V DC supplied by the bus coupler
    • Rated Breaking Capacity : 550 A at 440 V conforming to IEC 60947
    • Product Or Component Type : motor starter
    • Irms Rated Making Capacity : 550 A at 440 V conforming to IEC 60947
    • Product Name : TeSys island
    • Thermal Overload Class : class 5…30
    • [Uimp] Rated Impulse Withstand Voltage : 6 kV IEC 60947-1
    • Range : TeSys
    • Device Presentation : direct starter connected to an automation controller through a bus coupler || operational only when connected to a bus coupler
    • Motor Starter Type : direct on line
    • Utilisation Category : AC-1 || AC-2 || AC-3 || AC-4 || AC-3e
    • Function Available : upstream voltage presence detection || electrical line and load protection || power and energy monitoring when connected with TPRVM voltage module
    • [Ie] Rated Operational Current : 38 A (at <50 °C) at <= 440 V AC-3 || 40 A (at <50 °C) at <= 440 V AC-1
    • Overvoltage Category : III for Ue <= 480 V || II for Ue <= 690 V
    • Thermal Protection Adjustment Range : 0.76-38 A
    • Product Compatibility : TPRBC bus coupler || TPRVM voltage interface module
    • [Ue] Rated Operational Voltage : <= 480 V AC 47...63 Hz for overvoltage cat. III || <= 690 V AC 47...63 Hz for overvoltage cat. II
    • Maximum Horse Power Rating : 2 hp at 120 V AC 60 Hz for 1 phase motors || 5 hp at 240 V AC 60 Hz for 1 phase motors || 10 hp at 208 V AC 60 Hz for 3 phase motors || 10 hp at 240 V AC 60 Hz for 3 phase motors || 20 hp at 480 V AC 60 Hz for 3 phase motors || 25 hp at 600 V AC 60 Hz for 3 phase motors
    • Motor Power Kw : 9 kW at 230 V 50 Hz (AC-3) || 18.5 kW at 380...415 V 50 Hz (AC-3) || 18.5 kW at 440 V 50 Hz (AC-3) || 18.5 kW at 500 V 50 Hz (AC-3) || 18.5 kW at 690 V 50 Hz (AC-3)
    • [Ui] Rated Insulation Voltage : 690 V IEC 60947-4-1 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
    • Device Short Name : TPRST
    • Poles Description : 3P 3 NO
    • [Icw] Rated Short-Time Withstand Current : 430 A 40 °C - 1 s || 310 A 40 °C - 10 s || 150 A 40 °C - 1 min || 60 A 40 °C - 10 min