Safety controller, Modicon MCM, 8 inputs 2 outputs, monitors expansion modules, screw

CONTROLLER 8 INPUT 2 OUTPUT

SQDXPSMCMCP0802 XPSMCMCP0802 3606480748561
518.49 / EA
http://schema.org/OutOfStock
  • Depth: 114.5 mm
  • Number of Outputs: 2 Safety Outputs OSSD Contactor/drive Connection, 4 Test Line Control Outputs, 2 Configurable Diagnostic Connection, 2
This Modicon MCM safety controller CPU is supplied with 24Vdc, has 8 safe digital inputs, 2 start/restart interlock inputs, 2 output OSSD pairs, 4 test outputs and 2 status outputs and is fitted with captive screw clamp terminals. It embeds a Mini USB 2.0 connector to receive the configuration done with the software EcoStruxure Machine Expert - HVAC. It is an appropriate solution for machines with a small number of safety functions requiring the configuration flexibility of a safety controller. It can be used as standalone or with fourteen expansion modules. The system is expandable up to 128 inputs, 16 outputs and up to 32 diagnostic status outputs, ideal for machines requiring multiple safety function monitoring. This safety controller CPU figures LEDs on its front face, displaying the status (power supply, run, internal or external errors, inputs status, communication, master enable, restart signal, output channels). It is a CPU with a rated supply voltage of 24V DC and a maximum power dissipation of 3W. It is furnished with spring clamp terminals, removable terminal block for electrical connection. It is an IP20 rated product. It weighs 0.25kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. It is ideal for monitoring safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. The safe controller CPU Modicon MCM are certified by TüV SÜD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. Compatible accessories for Modicon MCM module are a memory card and the backplane connector. The safety controller CPU instals on Omega 35mm DIN rail conforming to EN 50022. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Integrated Connection Type : backplane expansion bus, USB 2.0 port
    • Maximum Number Of I O Expansion Module : 14 128 input, 14 16 output
    • Uimp Rated Impulse Withstand Voltage : 4 kV IEC 61800-5-1
    • Us Rated Supply Voltage : 24 V - 20...20 % DC
  • Important Information Attributes
    • Persona Type Ids : EU, OM, OM8
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder
    • Cable Cross Section : 0.2-2.5 mm² - AWG 24...AWG 14 solid without cable end0.2-1.5 mm² - AWG 24...AWG 16 flexible without cable end, 0.2-2.5 mm² - AWG 24...AWG 14 flexible without cable end, 0.25-1 mm² - AWG 23...AWG 18 flexible with cable end, without bezel, 0.25-2.5 mm² - AWG 23...AWG 14 flexible with cable end, with bezel, 0.25-1.5 mm² - AWG 23...AWG 16 flexible with cable end, without bezel, 0.5-1.5 mm² - AWG 20...AWG 16 flexible with cable end, with double bezel, 0.2-1 mm² - AWG 24...AWG 18 solid without cable end
    • Electromagnetic Compatibility : electrostatic discharge immunity test - test level: 6 kV (on contact) conforming to IEC 61000-4-2, electrostatic discharge immunity test - test level: 20 kV (on air) conforming to IEC 61000-4-2, susceptibility to electromagnetic fields - test level: 10 V/m (80...1000 MHz) conforming to IEC 61000-4-3, susceptibility to electromagnetic fields - test level: 30 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3
    • Function Of Module : emergency stop ISO 13850, guard monitoring EN/ISO 14119, enabling switch monitoring IEC 60947-5-1, light curtain monitoring IEC 61496-1, foot switch monitoring IEC 60947-5-1, magnetic switch monitoring EN/ISO 14119, two-hand control EN 574, safety mat monitoring EN/ISO 14119, enabling switch monitoring IEC 61326-1, muting function of light curtains IEC 60947-5-1, counter functions IEC 61800-5-2, speed monitoring IEC 61800-5-2
    • Local Signalling : 1 LED green PWR power ON, 1 LED green RUN RUN (status), 1 LED red E IN internal error, 1 LED red E EX external error, 1 LED orange COM communication, 1 LED blue EN master enable, 8 LEDs yellow IN input status, 2 LEDs green/red OUT output status, 2 LEDs yellow RST restart signal, 2 LEDs yellow STATUS output channel
    • Safety Level : can reach category 4 ISO 13849-1, can reach PL = e ISO 13849-1, type 4 IEC 61496-1, SILCL 3 IEC 62061
    • Safety Reliability Data : PFHd = 6.06E-9 1/h, DC > 99 %, MTTFd < 100 years high
    • Vibration Resistance : +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1, +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1, +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1+/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1, +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1, +/-0.35 mm (f= 10-55 Hz) conforming to IEC 61496-1
    • Certificate Agency : cULus, RCM, TÜV
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-03-26
    • Return Indicator : Y
    • Stocking Flag : N
    • Device Type : PLC System - PLC CPU
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Average Life Duration : 20 year(s)
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant
    • Rohs Eur Conformity Date : 1847
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : Yes
    • China Rohs Label : e
    • With Recycled Cardboard : No
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • Product Kit Identifier : N
    • Data Storage Equipment : SD card optional)
    • Device Short Name : XPSMCM
    • Electrical Connection : screw terminal
    • Inductive Load : 30 mH
    • Insulation : 250 V AC between power supply and housing IEC 61800-5-1
    • Load Capacitance : 0.82 µF
    • Mounting Support : omega 35 mm DIN rail EN 50022
    • Overvoltage Category : II
    • Power Dissipation In W : 3 W
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : safety controller CPU
    • Quality Labels : CE
    • Range Of Product : Modicon Safety automation
    • Returnability : Yes
    • Service Life : 20 year(s)
    • Shock Resistance : 10 gn 16 ms) 1000 shocks on each axis IEC 61496-1
    • Sustainable Packaging : No
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Connections Terminals : 6 captive screw terminals, removable terminal block
    • Warranty In Months : 18
    • Offer Owner Code : 190786
    • Pn : 1
    • Height Nominal : 99 mm
    • Width Nominal : 22.5 mm
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -10-55 °C, -10-55 °C
    • Ambient Air Temperature For Storage : -20-85 °C, -20-85 °C
    • Take Back : No
    • Reach Free Shvc : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Eu Rohs Directive : Compliant
    • Ip Degree Of Protection : IP20
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Relative Humidity : 10-95 %
  • General Attributes
    • Product Or Component Type : safety controller CPU
    • Range Of Product : Modicon Safety automation
  • ETIM
    • ETIM 8 : EC001449
    • ETIM 9 : EC001449
  • Output Attributes
    • Number Of Outputs : 2 safety outputs OSSD contactor/drive connection, 4 test line control outputs, 2 configurable diagnostic connection, 2
    • Discrete Output Current : 400 mA
    • Discrete Output Type : PNP
  • Input Attributes
    • Discrete Input Type : safety input, PNP
    • Number Of Inputs : 8 digital input connection, 2 digital interlock start/restart or external device monitoring
    • Synchronisation Time Between Inputs : < 0.5 ms, < 0.5 ms
    • Discrete Input Current : 400 mA
    • Discrete Input Voltage : 24 V
  • Specifications
    • Country of Origin : France, Italy, United States
    • Depth : 114.5 mm