Regulated Power Supply, 100...240V AC, 48V, 5A, single phase, Optimized

Regulated Power Supply, 100...240V AC, 48V, 5A, single phase, Optimized

SQDABLS1A48050 ABLS1A48050 3606482185227
370.59 / EA
http://schema.org/OutOfStock
  • Country of Origin: India
  • Depth: 117.6 mm
  • Dielectric Strength: 1500 V, 2000 V, 3000 V
  • Enclosure Material: Metal
  • Height: 123.6 mm
  • Input Voltage: ...240 V, ...375 V
  • Net Weight: 0.8 kg
  • Output Voltage: 48 V
  • Weight: 0.8 kg
  • Width: 60 mm
This product is part of the Modicon ABL range, an offer of power supplies for industrial use. It is a regulated switch mode power supply. It has a rated input of 100V to 240V AC and 140 V to 340 V DC, a rated output current of 5A at 48V DC and a rated power output of 240W. It supplies control circuits in industrial applications. This power supply has a protection against overload and short-circuit. It operates from minus 25degrees celcius to plus 70degrees celcius, and from 0meter to 2000meters or 5000meters with derating. It measures 123.6mm high, 60mm wide, and 117.6mm deep. It weighs 0.8kg. It is a power supply for industrial use. It conforms to CE, CB Scheme, cULus Listed, cURus Recognized, RCM, EAC, UKCA, KC certifications, to IEC/EN 62368-1, IEC/EN 61010-1/2, UL/CSA61010-1/2 standards. Acti9 iC60 range of Miniature Circuit Breakers is recommanded for its protection. Type of protection is 6 A, B or C curve. It installs on 35mm DIN rail. It brings energy to your automated systems. Designed with extreme compactness for simple machines and applications.
QTY
  • Product Description
  • Specifications
This product is part of the Modicon ABL range, an offer of power supplies for industrial use. It is a regulated switch mode power supply. It has a rated input of 100V to 240V AC and 140 V to 340 V DC, a rated output current of 5A at 48V DC and a rated power output of 240W. It supplies control circuits in industrial applications. This power supply has a protection against overload and short-circuit. It operates from minus 25degrees celcius to plus 70degrees celcius, and from 0meter to 2000meters or 5000meters with derating. It measures 123.6mm high, 60mm wide, and 117.6mm deep. It weighs 0.8kg. It is a power supply for industrial use. It conforms to CE, CB Scheme, cULus Listed, cURus Recognized, RCM, EAC, UKCA, KC certifications, to IEC/EN 62368-1, IEC/EN 61010-1/2, UL/CSA61010-1/2 standards. Acti9 iC60 range of Miniature Circuit Breakers is recommanded for its protection. Type of protection is 6 A, B or C curve. It installs on 35mm DIN rail. It brings energy to your automated systems. Designed with extreme compactness for simple machines and applications.
  • Specifications
    • Country of Origin : India
    • Width : 60 mm
    • Height : 123.6 mm
    • Weight : 0.8 kg
    • Range Of Product : Modicon Power Supply
    • Output Voltage : 48 V DC
    • Product Or Component Type : power supply
    • Power Supply Type : regulated switch mode
    • Input Voltage : 100...240 V AC single phase || 100...240 V AC phase to phase || 140...375 V DC
    • Power Supply Output Current : 5 A
    • Kw Rating : 240 W
    • Enclosure Material : metal
  • Complementary
    • Output Coupling : single/parallel by switch
    • Height : 123.6 mm
    • Residual Ripple : 200 mV
    • Status Led : 1 LED (Green) output voltage
    • Holding Time : > 20 ms 115 V AC || > 20 ms 230 V AC
    • Efficiency At Full Load : 85...264 V AC || 120...375 V DC
    • Earthing System : TN || TT || IT
    • Connections - Terminals : screw connection 0.75...4 mm², AWG 18...AWG 12) without wire end ferrule output || screw connection 0.75...4 mm², AWG 18...AWG 12) with wire end ferrule output || screw connection 0.75...4 mm², AWG 18...AWG 12) without wire end ferrule input || screw connection 0.75...4 mm², AWG 18...AWG 12) with wire end ferrule input
    • Dielectric Strength : 3000 V AC with input to output || 2000 V AC with input to ground || 1500 V AC with output to ground
    • Network Frequency Limits : 50-60 Hz
    • Marking : CE || UKCA
    • Current Consumption : < 2.8 A 115 V AC || < 1.4 A 230 V AC || < 2.4 A 140 V DC
    • Supply : SELV IEC 60950-1 || SELV IEC 60204-1 || SELV IEC 60364-4-41
    • Net Weight : 0.8 kg
    • Maximum Leakage Current : 1 mA 240 V AC
    • Input Protection Type : integrated fuse (not interchangeable) 6.3 A || external protection (recommended) 20 A || external protection (recommended) 6 A
    • Output Protection Type : against overload and short-circuits, protection technology: automatic reset || against over temperature, protection technology: manual reset || against overvoltage, protection technology: manual reset
    • Service Life : 10 year(s) 40 °C 50 % load
    • Meantime Between Failure [Mtbf] : at 25 °C, full load conforming to SR 332
    • Power Dissipation In W : 36 W
    • Output Voltage Limits : 44…54 V
    • Mounting Support : top hat type TH35-15 rail IEC 60715 || top hat type TH35-7.5 rail IEC 60715 || double-profile DIN rail
    • Load Capacitance : 8000 µF
    • Response Time : < 1 s
    • Line And Load Regulation : < 1.5 % network 0 to 100 % load at 25 °C || < 0.5 % network full voltage range in line at 25 °C
    • Width : 60 mm
    • Overvoltage Category : II
    • Inrush Current : 30 A 115 V || 60 A 230 V
    • Efficiency : 85 % 115 V AC || 88 % 230 V AC
    • Depth : 117.6 mm
    • Power Factor : 0.95 at 115 V AC || 0.95 at 230 V AC
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : No
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP2007005EN
    • Packaging Without Single Use Plastic : Yes
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Scip Number : 698d9b2a-7a6a-4b8f-a149-489156f55645
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Circularity Profile : ENVEOLI2007005EN
    • Take-Back : No
    • Sustainable Packaging : No
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
  • Environment
    • Standards : IEC 62368-1 || EN/IEC 61204-3 || IEC 61000-6-1 || IEC 61000-6-2 || IEC 61000-6-3 || IEC 61000-6-4 || IEC 61000-3-2 || EN 61000-3-3 || UL 62368-1 || CSA C22.2 No 62368-1 || CSA C22.2 No. 107.1
    • Ambient Air Temperature For Operation : -20-40 °C without derating mounting position A 115 V AC < 6561.68 ft (2000 m) || 40-70 °C with current derating mounting position A 115 V AC < 6561.68 ft (2000 m) || 40-70 °C with current derating of 1.67 % per °C mounting position A 115 V AC < 6561.68 ft (2000 m) || 50-70 °C with current derating of 2.5 % per °C mounting position A 230 V AC < 6561.68 ft (2000 m)
    • Product Certifications : CE || cUL Listed || cUL Recognized || RCM || CB Scheme || EAC || KC || UKCA || cURus
    • Pollution Degree : 2
    • Electromagnetic Compatibility : immunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2 || immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2 || immunity to conducted RF disturbances - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3 || immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming to IEC 61000-4-3 || immunity to conducted RF disturbances - test level: 5 V/m (2.7...6 GHz) conforming to IEC 61000-4-3 || immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4 || surge immunity test - test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5 || surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5 || immunity to conducted RF disturbances - test level: 15 V (0.15...80 MHz) conforming to IEC 61000-4-6 || immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8 || immunity to voltage dips conforming to IEC 61000-4-11 || disturbing field emission conforming to EN 55016-2-3 || limits for harmonic current emissions conforming to IEC 61000-3-2 || conforming to EN 55016-1-2 || conforming to EN 55016-2-1
    • Shock Resistance : 150 m/s² 11 ms
    • Vibration Resistance : 3 mm (f= 2-9 Hz) conforming to IEC 60068-2-6 || 10 m/s² (f= 9-200 Hz) conforming to IEC 60068-2-6
    • Ip Degree Of Protection : IP20
    • Operating Altitude : < 5000 m overvoltage category II
    • Electrical Shock Protection Class : class I
    • Electromagnetic Emission : conducted emissions IEC 61000-6-3 || radiated emissions IEC 61000-6-4