Schneider Electric at Mayer

electronic protection module, phaseo ABL7 ABL8, 28 to 28.8V DC, 10A, for regulated SMPS, 2 pole breaking by channel

PHASEO PROTECTION MODULE - UNI

SQDABL8PRP24100 ABL8PRP24100 3389119406918
417.21 / EA
http://schema.org/OutOfStock
  • Dielectric Strength: 500 V
  • Input Voltage: 24-28.8 V
  • Warranty Length: 18 mth
This ABL8 electronic protection module supplies direct current voltage. It has a rated input of 24V to 28.8V DC, a rated output current of 10A. This electronic protection module is ideal to protect up to 4 circuits against overloads and short-circuits with a total rated current of 10 amperes. It controls and protects up to 4 independent auxiliary circuits with a single power supply unit. Its complementary function is a 1-pole breaking by channel. It has LED diagnostics indicator available in the front for troubleshooting instantly. It weighs 0,470kg. It is a functionnal module for power supply for industrial use, rail mounting. It conforms to UL 508, CSA C22.2 No 60950-1 standards. It is certified by EAC, RCM. This functional module is mainly compatible with Modicon ABL8RP and Modicon ABL8WP Universal power supplies. It has LED diagnostics indicator available in the front for troubleshooting instantly. It installs on DIN rail. It brings energy to your automated systems. Designed for simple machines and applications, modular power supplies are primarily appreciated for their extreme compactness.
QTY
  • Product Description
  • Features
  • Specifications
This ABL8 electronic protection module supplies direct current voltage. It has a rated input of 24V to 28.8V DC, a rated output current of 10A. This electronic protection module is ideal to protect up to 4 circuits against overloads and short-circuits with a total rated current of 10 amperes. It controls and protects up to 4 independent auxiliary circuits with a single power supply unit. Its complementary function is a 1-pole breaking by channel. It has LED diagnostics indicator available in the front for troubleshooting instantly. It weighs 0,470kg. It is a functionnal module for power supply for industrial use, rail mounting. It conforms to UL 508, CSA C22.2 No 60950-1 standards. It is certified by EAC, RCM. This functional module is mainly compatible with Modicon ABL8RP and Modicon ABL8WP Universal power supplies. It has LED diagnostics indicator available in the front for troubleshooting instantly. It installs on DIN rail. It brings energy to your automated systems. Designed for simple machines and applications, modular power supplies are primarily appreciated for their extreme compactness.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Maximum Output Current : 10 A per channel, rating: 1/2.5/4/5/7/8/10
  • Important Information Attributes
    • Persona Type Ids : EU, OM, OM8
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder
    • Dielectric Strength : 500 V between input and ground, 500 V between output and ground
    • Environmental Characteristic : EMC conforming to IEC 61000-6-3, EMC conforming to IEC 61000-6-2, safety conforming to IEC 60950-1, safety conforming to EN/IEC 61204-3
    • Fixing Mode : by clips 35 mm symmetrical DIN rail vertical, on panel
    • Local Signalling : 1 LED per channel (green/red) for channel status, 1 relay for channel status
    • Name Of Test : electrostatic discharges IEC 61000-4-2, emission IEC 61000-6-3, induced electromagnetic field IEC 61000-4-6 level 3, radiated electromagnetic field IEC 61000-4-3 level 3, rapid transient IEC 61000-4-4 level 3, surge IEC 61000-4-5 level 2, conducted/radiated emissions EN 55022 Class B, emission EN 50081-1
    • Vibration Resistance : 2 gn (f= 11.9-150 Hz) conforming to IEC 61131-2, 3.5 mm (f= 3-11.9 Hz) conforming to IEC 61131-2
    • Connections Terminals : for input connection: screw type terminals, connection capacity: 4 x 0.5...4 x 10 mm² AWG 20...AWG 8, for diagnostic relay: removable screw terminal block, connection capacity: 1 x 2.5 mm² AWG 14, for output connection: screw type terminals, connection capacity: 8 x 0.5...8 x 4 mm² AWG 20...AWG 10
    • Carbon Footprint Of The Distribution Phase A4 : 0.066646, 0.1 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.4 kg CO2 eq., 0.38236
    • Carbon Footprint Of The Installation Phase A5 : 0.0062641, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 19 kg CO2 eq., 19.386
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 687 kg CO2 eq., 686.71
    • Certificate Agency : RCM, EAC
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-01-12
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Device Type : PLC System - PLC Component
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Manufacturing Carbon Footprint : 19.386
    • Use Carbon Footprint : 686.71
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1412018EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 1908
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 5
    • With Recycled Cardboard : No
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • Product Kit Identifier : N
    • Compatibility Code : ABL8P
    • Complementary Function : 2-pole breaking by channel
    • Load Capacitance : 2200 µF
    • Marking : CE
    • Overvoltage Category : class II conforming to VDE 0106-1
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : electronic protection module
    • Range Of Product : Phaseo
    • Returnability : No
    • Software Version : EIME v5.9.3
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 707 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Carbon Footprint Kg Co2 Eq Total Life Cycle : 706.55
    • Warranty In Months : 18
    • Pep Code : ENVPEP1412018EN
    • Database Version : 2020-12
    • Pep Verification Date : 2022-09-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : referent product
    • Functional-unit Description : To provide discriminating protection against overloads and short-circuits 100% of the time at 16W during 10 years.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : Unit
    • Reference Lifetime, In Y : 10
    • Energy Consumption On Product Lifetime, In Kwh : 1401.6
    • Energy Model - Manufacturing [A1-a3] : Energy model used: Philippines
    • Energy Model - Installation [A5] : Electricity mix; AC; < 1kV; EU-27
    • Energy Model - Use [B6] : Electricity mix; AC; < 1kV; EU-27
    • Energy Model - End Of Life [C1-c4] : Electricity mix; AC; < 1kV; EU-27
    • Recyclability Potential, In % : 38
    • Acidification Of Soil And Water (Kg.Equivalent.So2) Total Life Cycle : 2.8956
    • Acidification Of Soil And Water (Kg.Equivalent.So2) Operational Energy Use [B6] : 2.8645
    • Air Pollution (M3) Total Life Cycle : 31529
    • Air Pollution (M3) Manufacturing [A1-a3] : 1963.2
    • Air Pollution (M3) Distribution [A4] : 2.8351
    • Air Pollution (M3) Operational Energy Use [B6] : 29556
    • Air Pollution (M3) End Of Life [C1-c4] : 6.8096
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Total Life Cycle : 7998
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Manufacturing [A1-a3] : 201.55
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Operational Energy Use [B6] : 7794.7
    • Global Warming (Kg.Equivalent.Co2) Total Life Cycle : 706.55
    • Global Warming (Kg.Equivalent.Co2) Manufacturing [A1-a3] : 19.386
    • Global Warming (Kg.Equivalent.Co2) Operational Energy Use [B6] : 686.71
    • Hazardous Waste Disposed Of (Kg) Total Life Cycle : 12.305
    • Hazardous Waste Disposed Of (Kg) Manufacturing [A1-a3] : 11.049
    • Hazardous Waste Disposed Of (Kg) Operational Energy Use [B6] : 0.358
    • Materials For Recycling (Kg) Total Life Cycle : 0.2884
    • Materials For Recycling (Kg) Installation [A5] : 0.1115
    • Net Use Of Fresh Water (M3) Total Life Cycle : 2490.3
    • Net Use Of Fresh Water (M3) Manufacturing [A1-a3] : 0.3738
    • Net Use Of Fresh Water (M3) Operational Energy Use [B6] : 2489.9
    • Non-hazardous Waste Disposed Of (Kg) Total Life Cycle : 2564.5
    • Non-hazardous Waste Disposed Of (Kg) Manufacturing [A1-a3] : 4.1456
    • Non-hazardous Waste Disposed Of (Kg) Operational Energy Use [B6] : 2560.3
    • Photochemical Ozone Formation (Kg.Equivalent.C2h4) Operational Energy Use [B6] : 0.1574
    • Radioactive Waste Disposed Of (Kg) Total Life Cycle : 1.7121
    • Radioactive Waste Disposed Of (Kg) Operational Energy Use [B6] : 1.7099
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Total Life Cycle : 12215
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Manufacturing [A1-a3] : 242.53
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 11971
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) End Of Life [C1-c4] : 0.9463
    • Total Use Of Primary Energy During The Life Cycle (Mj) Total Life Cycle : 13969
    • Total Use Of Primary Energy During The Life Cycle (Mj) Manufacturing [A1-a3] : 251.66
    • Total Use Of Primary Energy During The Life Cycle (Mj) Operational Energy Use [B6] : 13715
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Total Life Cycle : 1753.1
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Manufacturing [A1-a3] : 9.1309
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 1744
    • Use Of Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 5.525
    • Use Of Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 5.525
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 12210
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 237
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 11971
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) End Of Life [C1-c4] : 0.9463
    • Use Of Renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 1.9868
    • Use Of Renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 1.9868
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 1751.1
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 7.1442
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 1744
    • Water Pollution (M3) Total Life Cycle : 30274
    • Water Pollution (M3) Manufacturing [A1-a3] : 1909.6
    • Water Pollution (M3) Distribution [A4] : 10.96
    • Water Pollution (M3) Operational Energy Use [B6] : 28336
    • Water Pollution (M3) End Of Life [C1-c4] : 15.883
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -25-60 °C, -25-60 °C
    • Ambient Air Temperature For Storage : -40-85 °C, -40-85 °C
    • Relative Humidity : 0-90 % during operation, 0-95 % during storage
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 706.55
    • Circularity Profile : ENVEOLI1412018EN
    • Environmental Disclosure : ENVPEP1412018EN
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP20 conforming to IEC 60529
    • Operating Altitude : 6561.68 ft (2000 m)
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1412018EN
    • Pep Verification Date : 2022-09-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : electronic protection module
    • Range Of Product : Phaseo
  • ETIM
    • ETIM 8 : EC001440
    • ETIM 9 : EC001440
  • Output Attributes
    • Output Protection Type : against overload, protection technology: 1.3 x In, against short-circuits, protection technology: automatic reset, line protection, protection technology: 1 x 15 A integrated fuse per channel
    • Output Voltage : (Uin-0.3) V DC, (Uin-0.3) V DC(Uin-0.3) V DC, (Uin-0.3) V DC
    • Maximum Output Current : 10 A per channel, rating: 1/2.5/4/5/7/8/10
    • Number Of Output Channels : 4
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Input Attributes
    • Input Current : 40 A
    • Input Voltage : 24...28.8 V DC
    • Input Voltage Limits : 19...32 V
  • Specifications
    • Country of Origin : Brazil, China, France, Mexico, Philippines