PowerLogic HDPM6000R retrofit module 42-circuits

POWERLOGIC HDPM6000R RETROFIT

SQDMETSEHDPM6R42 METSEHDPM6R42 3606481986597
3021.09 / EA
http://schema.org/OutOfStock
  • Country of Origin: USA
  • Depth: 172.97 mm
This is an integrated solution for monitoring multi-circuits and power quality by using a single meter. The meter is designed for retrofit and is used for critical power operations in data centres, facilities and energy management in buildings. Allow monitoring of loads up to 4000A with utility grade accuracy on all branch channels. This combination include 1 retrofit element for current transformers in order to measure values for 42 branch circuits. Allow measurement of energy, power demand, instantaneous power, current, harmonic, voltage and more - in total or per phases. Devices can be connected in dasy-chain thanks to CAT5 or CAT6 straight-through Ethernet cable. The HDPM6000 series can also maintain multiple, concurrent sessions with EPMS, DCIM or BMS applications via the Modbus, SNMP and BACnet IP protocols. The retrofit module dimensions are 173mm in width connector included, 64mm in height and 173.48mm in depth. Certified for IEC61326-1 and EN61326-1:2020, related to Industrial Electromagnetic Environment. The elements can be mounted on a DIN rail thanks to the clips at the back side. The system PowerLogic HDPM6000 can help you identify increased harmonics in the rack servers to detect a potential disruption. Thanks to daisy-chain, it is possible to connect additional modules if the head unit capacity isn't exceeded.
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Communications & Management Attributes
    • Communication Of Data : power quality, reading of measurements, percentage of load
    • Communication Port Protocol : TCP/IP, Modbus, SNMP, BACnet
    • Communication Port Support : 2 RJ45 ETHERNET
  • Important Information Attributes
    • Energy Management : asset management, measurement, cost management
    • Market Segment : data center, industrial buildings, healthcare, non-critical buildings
    • Mounting Mode : clipped, by screws
    • Mounting Support : 35 mm DIN rail, enclosure
    • Power Quality Analysis : total harmonic distortion
    • Type Of Measurement : active energy all channels, active power all channels, apparent power all channels, reactive power all channelscurrent per channel, current all channels, active energy per channel, active power per channel, apparent power per channel, reactive power per channel, frequency, power factor per channel, power factor average
    • Carbon Footprint Of The Distribution Phase A4 : 0.5236748501694074, 0.5 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 3 kg CO2 eq., 2.934429375546221
    • Carbon Footprint Of The Installation Phase A5 : 0.015840709486106035, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 34 kg CO2 eq., 34.1494862881984
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 85 kg CO2 eq., 84.9371099700229
    • Certificate Agency : UL Listed conforming to UL 508 A, CE, cURus
    • Other Technical Guide : https://download.schneider-electric.com/files?p_Doc_Ref=PLSED310185EN&p_File_name=PLSED310185EN.pdf, PLSED310185EN
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-10
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Device Type : Relay, Control & Measurement - measuring, monitoring device
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : DPIBS
    • Average Life Duration : 15 year(s)
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2510043EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2105
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 7
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Product Kit Identifier : N
    • Device Short Name : HDPM6000R
    • Energy Efficiency Optimized : False
    • Measurement Category : category III
    • Memory Capacity : 8 GB
    • Noise Level : 0-65 dB
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Name : PowerLogic HDPM6000
    • Product Or Component Type : metering module
    • Range : PowerLogic
    • Returnability : No
    • Sampling Rate : 128 samples/cycle
    • Software Version : v6.2.4
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 123 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Warranty In Months : 18
    • Pep Code : ENVPEP2510043EN
    • Database Version : 2024-01
    • Pep Verification Date : 2025-10-23
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional-unit Description : Other switchgear and controlgear solutions mentioned in the scope (e.g. fuses TC32, all-or-nothing relays TC94, Measuring relays and protection equipment TC95), apply the general rules of PCR and mention in the accompanying report the functional unit, the reference product characteristics, the reference lifetime and the use scenario which are applied consistently with the relevant IEC technical standards.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime, In Y : 10
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model - Installation [A5] : No energy used
    • Energy Model - Use [B6] : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model - End Of Life [C1-c4] : Global, European and French datasets are used.
    • Recyclability Potential, In % : 54
    • Offer Owner Code : 190781
    • Pn : 1
    • Height Nominal : 64 mm
    • Width Nominal : 173.48 mm
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -20-60 °C, -20-60 °C
    • Ambient Air Temperature For Storage : -40-85 °C, -40-85 °C
    • Operating Altitude : <= 6561.68 ft (2000 m), <= 6561.68 ft (2000 m)
    • Relative Humidity : 5-90 %
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 122.56054119342303
    • Circularity Profile : ENVEOLI2510043EN
    • Environmental Disclosure : ENVPEP2510043EN
    • Eu Rohs Directive : Compliant By Exemption
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2510043EN
    • Pep Verification Date : 2025-10-23
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : metering module
  • ETIM
    • ETIM 8 : EC001420
    • ETIM 9 : EC001420
  • Input Attributes
    • Analogue Input Type : external CT
    • Number Of Inputs : 42 current
  • Specifications
    • Country of Origin : United States
    • Depth : 172.97 mm