SQUARE D

PowerLogic EM3500 DIN rail meter - Modbus 2 quadrant - flexible transducer

EM3500, 2 QUAD, MODBUS, ROPE

SQDMETSEEM3550A METSEEM3550A 3606481969262
991.86 / EA
http://schema.org/OutOfStock
  • Country of Origin: USA
  • Depth: 59 mm
  • Display Type: Backlit LCD
  • Height: 91 mm
  • Number of Outputs: 1 Alarm Output, 1 Pulse
  • Width: 107 mm
The EM3500 series offer a three-phases DIN rail-mounted energy meters fitted for accurate cost allocation and sub-metering. EM35xxA models are designed for use exclusively with Rogowski coil CTs where integrator and power supply for the CTs are built into the meter. Not recommanded for high harmonic application. Current input from 20A to 5000A with the Rogowski coil, ANSI C12.20 0.5% accuracy, IEC 62053-22 class 0.5S. Modbus, pulse output, and phase alarms are all provided to suit a wide variety of applications. Suitable for a 230V AC network, with a supply voltage range of 90V AC to 300V AC at 50Hz or 60Hz. Compliant with UL508, CSA 22.2 number 14-05 and EN 61010-1. Product dimensions are as follows: width 107 mm, depth 59 mm, height 91 mm and product weight 280 g.
QTY
  • Product Description
  • Features
  • Specifications
The EM3500 series offer a three-phases DIN rail-mounted energy meters fitted for accurate cost allocation and sub-metering. EM35xxA models are designed for use exclusively with Rogowski coil CTs where integrator and power supply for the CTs are built into the meter. Not recommanded for high harmonic application. Current input from 20A to 5000A with the Rogowski coil, ANSI C12.20 0.5% accuracy, IEC 62053-22 class 0.5S. Modbus, pulse output, and phase alarms are all provided to suit a wide variety of applications. Suitable for a 230V AC network, with a supply voltage range of 90V AC to 300V AC at 50Hz or 60Hz. Compliant with UL508, CSA 22.2 number 14-05 and EN 61010-1. Product dimensions are as follows: width 107 mm, depth 59 mm, height 91 mm and product weight 280 g.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary
    • Communication Port Support : screw terminal block RS485
    • [Ue] Rated Operational Voltage : 90...347 V AC 50/60 Hz between phase and neutral UL || 156...600 V AC 50/60 Hz between phases UL || 90...300 V AC 50/60 Hz between phase and neutral CE || 125...300 V DC
    • Standards : IEC 61010-1 || CSA C22.2 No 14-05 || UL 508
    • Number Of Outputs : 1 alarm output || 1 pulse
    • Mounting Support : DIN rail
    • Power Consumption In Va : 5-5 VA 347 V AC between phase and neutral) || 5-5 VA 600 V AC between phases)
    • Product Certifications : CE conforming to IEC 61010 || cULus conforming to UL 508
    • Type Of Measurement : active and reactive power total || active and reactive power per phase || apparent power total || apparent power per phase || power factor total || power factor per phase || peak demand power || current || voltage || frequency
    • Communication Port Protocol : Modbus RTU 1200…38400 bps - 2-wire
    • Communication Service : total cumulated energy || total cumulated active energy
    • Ride-Through Time : 100 ms 120 V AC
    • Display Digits : 5
    • Tamperproof Of Settings : protected by access code
    • Measurement Current : 20-5000 A
    • Information Displayed : status and alert || communication with system || input/output status || error || Tx activity || Rx activity || instant power per usage
    • Function Available : external synchronisation to communication || fixed or rolling block
    • Mounting Mode : clip-on || by screws
    • Network Frequency : 50 Hz || 60 Hz
    • Local Signalling : Red LED threshold reached || Green flashing LED output signal
    • Power Consumption In W : 3 W 300-300 V
    • Measurement Accuracy : power +/- 0.5 % || energy +/- 0.5 %
    • Technology Type : electronic
    • Poles Description : 3P + N
    • Data Recording : energy consumption logs
    • Analogue Input Type : Rogowski coil 50...5000 A
    • Display Type : Backlit LCD
    • Device Application : sub billing || partial meter
    • Accuracy Class : class 0.5S power IEC 62053-22 || class 0.5S energy IEC 62053-22 || class 0.5S power ANSI C12.20 || class 0.5S energy ANSI C12.20
    • Rated Voltage : 90-347 V
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : No
    • Mercury Free : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Minimum Percentage Of Recycled Plastic Content : 0
    • Take-Back : No
    • Eu Rohs Directive : Compliant with Exemptions
  • Specifications
    • Country of Origin : United States
    • Width : 107 mm
    • Height : 91 mm
    • Product Or Component Type : energy meter
    • Product Name : PowerLogic EM3500
    • Range : PowerLogic
    • Device Short Name : EM3550A
    • Metering Type : peak demand power PM, QM, SM || demand power P, Q, S || voltage U21, U32, U13, V1, V2, V3 || current I1, I2, I3, Iavg
  • Environment
    • Ambient Air Temperature For Operation : -30-70 °C
    • Height : 91 mm
    • 9 Mm Pitches : 12
    • Color : dark grey
    • Ambient Air Temperature For Storage : -40-85 °C
    • Relative Humidity : 0-95 %
    • Width : 107 mm
    • Depth : 59 mm