SQUARE D

Power quality meter, PowerLogic PM8000, Essential, transducer and remote display, 64MB, 128s/c

Power quality meter, PowerLogi

SQDMETSEPM8114 METSEPM8114 3606486874745
12002.13 / EA
http://schema.org/OutOfStock
  • Country of Origin: Canada
  • Depth: 90.8 mm
  • Number of Outputs: 1 Pulse
The PowerLogic PM8114 comes in a DIN Rail mount form factor with a remote display and LVDC control power. It is designed to help you ensure reliability and efficiency of your power-critical facilitiy. With its modular, flexible, and power ION technology, you can build custom applications for each meter. It comes with revenue grade accuracy, multiple communication ports, and a color graphical display. Certified by third party labs for Class 0.2S energy accuracy (IEC62052-11, IEC62053-24, IEC62053-22). Cybersecurity features include secure protocols (HTTPs, sFTP, Secure ION), security event logging, Syslog protocol. Ability to enable/disable communication ports and support 50 configurable user account to help manage access. With 64MB of memory to support up to 10 data logs (160 channels), 50+ user-definable alarms, waveform captures upto 128 samples/cycle, 1/2 cycle RMS logging. The storage can also be used for custom web pages, min/max logs, energy trends, and Time of Use. The ability to timestamp events to +/-1ms utilizing time synchronization. Time synch method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 3 digital inputs and one digital output, plus the ability to add up to 4 option modules. I/O option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs Wide control power range of 20-60 VDC. Operating environment of -25 to +70°C; Humidity rating of 5% to 95%; Altitude up to 3000 m.
QTY
  • Product Description
  • Specifications
The PowerLogic PM8114 comes in a DIN Rail mount form factor with a remote display and LVDC control power. It is designed to help you ensure reliability and efficiency of your power-critical facilitiy. With its modular, flexible, and power ION technology, you can build custom applications for each meter. It comes with revenue grade accuracy, multiple communication ports, and a color graphical display. Certified by third party labs for Class 0.2S energy accuracy (IEC62052-11, IEC62053-24, IEC62053-22). Cybersecurity features include secure protocols (HTTPs, sFTP, Secure ION), security event logging, Syslog protocol. Ability to enable/disable communication ports and support 50 configurable user account to help manage access. With 64MB of memory to support up to 10 data logs (160 channels), 50+ user-definable alarms, waveform captures upto 128 samples/cycle, 1/2 cycle RMS logging. The storage can also be used for custom web pages, min/max logs, energy trends, and Time of Use. The ability to timestamp events to +/-1ms utilizing time synchronization. Time synch method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 3 digital inputs and one digital output, plus the ability to add up to 4 option modules. I/O option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs Wide control power range of 20-60 VDC. Operating environment of -25 to +70°C; Humidity rating of 5% to 95%; Altitude up to 3000 m.
  • Communications & Management Attributes
    • Communication Port Protocol : Modbus RTU 115 kbauds - 2-wire, ION 115 kbauds - 2-wire, DNP3, IEC 61850, Modbus TCP/IPEthernet Modbus TCP/IP daisy chain 10/100 Mbit/s, RSTP 801.1d 2004
    • Communication Service : RSTP support, DHCP, SMTP e-mail notification, NTP time synchronization, SNMP, PTP time synchronization
    • Communication Network Type : IPv6 (internet protocol)
    • Communication Port Support : ETHERNETscrew terminal block RS485
  • Complementary Attributes
    • Line Rated Current : 5 A, 1 A, 10 A
  • Important Information Attributes
    • Cybersecurity : enable/disable communication ports, robust security logs, port hardening, password protection, Syslog protocol support
    • Data Recording : harmonics logs, waveform logs, trending/forecasting, event logs, alarm logs, data logs, sequence of event recording, sag and swell logs, min/max of instantaneous values, time stamping, GPS synchronisation, 10 data recorders
    • Device Application : power monitoring, WAGES metering
    • Electromagnetic Compatibility : electrostatic discharge conforming to IEC 61000-4-2radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3electrical fast transient/burst immunity test conforming to IEC 61000-4-4surge immunity test conforming to IEC 61000-4-5conducted RF disturbances conforming to IEC 61000-4-6magnetic field at power frequency conforming to IEC 61000-4-8voltage dips and interruptions immunity test conforming to IEC 61000-4-11immunity to impulse waves conforming to IEC 61000-4-12conducted and radiated emissions conforming to EN 55022, conducted and radiated emissions conforming to EN 55011, conducted and radiated emissions conforming to FCC part 15, conducted and radiated emissions conforming to ICES-003conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579surge withstand conforming to IEEE C37.90.1
    • Information Displayed : voltage, current, frequency, power, energy consumption, harmonic distortion
    • Isolation Voltage : III400-690 V conforming to IEC 61010-1:ed. 3, III400-690 V conforming to EN 61010-1:ed. 3III347-600 V conforming to UL 61010-1:ed. 3, III347-600 V conforming to CSA C22.2 No 61010-1:ed. 3
    • Market Segment : buildings large building network management: main incomerbuildings large building network management: sub feederbuildings multi-site network management: sub feeder, data center small building network management: sub feederhealthcare multi-site network management: sub feeder, industry network management: sub feeder, buildings large building cost management: billing: sub feeder, buildings small building network management: main incomer, buildings medium building network management: main incomer, buildings multi-site network management: main incomer, data center large building network management: billing: main incomer, healthcare medium building network management: main incomer, industry multi-site network management: main incomer, utility network management: sub feeder
    • Measurement Accuracy : current +/- 0.1 %, voltage +/- 0.1 %active energy +/- 0.2 %
    • Mounting Mode : clip-on, flush-mounted
    • Network Frequency : 50 Hz, 60 Hz
    • Number Of Poles : 3P, 1P + N, 3P + N
    • Power Quality Analysis : EN 50160 2010 compliance reportIEEE 519 2014 compliance report, up to the 63rd harmonic, harmonic distortion, waveform capture, voltage sag and swell detection, programmablity (logic and math functions)IEC 62586 power quality monitoring
    • Type Of Measurement : apparent power per phase, rmspower factor per phase, rmscurrentvoltage total, frequency total, active and reactive power total, apparent power total, power factor total, active and reactive power per phase, rms
    • Web Services : customizable home page, file upload/download via FTP, file upload/download via SFTP, web server, alarm notification by e-mail, viewing of captured waveform (FTP), viewing of captured waveform (web), HTTPS server
    • Certificate Agency : CE, cULus, N998
    • Carbon Footprint Of The Distribution Phase [A4] : 0.6205364693221147, 0.6 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 3 kg CO2 eq., 2.942759942214244
    • Carbon Footprint Of The Installation Phase [A5] : 0.04030272069320569, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 159 kg CO2 eq., 159.41182079984893
    • Carbon Footprint Of The Use Phase [B2 B3 B4 B6] : 199 kg CO2 eq., 199.2820090070477
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-10
    • Return Indicator : Y
    • Stocking Flag : Y
    • Device Type : Relay, Control & Measurement - measuring, monitoring device
    • Serviceability : No
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2508020EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2345
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 7
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Dangerous Goods Code : LITHIUM METAL BATTERIES IN EQUIP. BUTTON CELL-BAT EXEMPT
    • Product Kit Identifier : N
    • Device Short Name : PM8114
    • Display Resolution : 320 x 240 pixels QVGA
    • Display Type : remote LCD display
    • Energy Efficiency Optimized : False
    • Frequency Measurement Range : 42-69 Hz
    • Installation Category : III
    • Measurement Current : 50-10000 mA
    • Measurement Voltage : 57-400 V AC 42...69 Hz between phase and neutral100-690 V AC 42...69 Hz between phases
    • Memory Capacity : 64 MB
    • Mounting Support : DIN rail meter deviceframework remote display
    • Power Consumption In W : 18 W
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Name : PowerLogic PM8000
    • Product Or Component Type : power meter
    • Provided Equipment : remote display
    • Range : PowerLogic
    • Returnability : Yes
    • Sampling Rate : 128 samples/cycle
    • Software Version : v6.2.4
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 362 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Pep Code : ENVPEP2508020EN
    • Database Version : 2024-01
    • Pep Verification Date : 2025-09-15
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional-unit Description : Technical data:& 10Supply Voltage& 1090...415 V AC 45...65 Hz +/- 10 %& 10110...415 V DC +/- 10 %& 10Measurement voltage& 1057…400 V AC 42...69 Hz between phase and neutral& 10100…690 V AC 42...69 Hz between phases& 10Measurement current& 1050…10000 mA
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime In Y : 10
    • Energy Consumption On Product Lifetime In Kwh : 414.348
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Low voltage; 2020; Canada, CA
    • Energy Model - Installation [A5] : No energy used
    • Energy Model - Use [B6] : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model - End Of Life [C1-c4] : Global, European and French datasets are used.
    • Recyclability Potential In % : 17
    • Height Nominal : 90.5 mm
    • Width Nominal : 90.5 mm
    • [Us] Rated Supply Voltage : 20...60 V DC +/- 10 %
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 1.268 kg
    • Take-back : No
    • Warranty (In Months) : 18
    • Customs Code : 9028300000
    • Other Technical Guide Name : PLSED310058EN
  • Environment Attributes Main
    • Ambient Air Temperature For Storage : -40-85 °C, -40-85 °C
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Carbon Footprint : 362.2974289391262
    • Ambient Air Temperature For Operation : -25-70 °C-25-70 °C
    • Circularity Profile : ENVEOLI2508020EN
    • Environmental Disclosure : ENVPEP2508020EN
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP30 conforming to IEC 60529
    • Operating Altitude : 9842.52 ft (3000 m)
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 5-95 %
    • Pep Code : ENVPEP2508020EN
    • Pep Verification Date : 2025-09-15
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : power meter
    • Provided Equipment : remote display
  • ETIM
    • ETIM 8 : EC002301
    • ETIM 9 : EC002301
  • Output Attributes
    • Number Of Outputs : 1 pulse
  • Input Attributes
    • Analogue Input Type : voltage (impedance 5 MOhm)current (impedance 0.3 mOhm)
    • Number Of Inputs : 3 digital 30 V AC3 digital 60 V DC
  • Specifications
    • Country of Origin : Canada
    • Depth : 90.8 mm