Power quality meter, PowerLogic PM8000, Advanced, integrated display, 512MB, 512s/c

Power quality meter, PowerLogic PM8000, Advanced, integrated display, 512MB, 512s/c

SQDMETSEPM8340 METSEPM8340 3606486874752
24772.34 / EA
http://schema.org/OutOfStock
  • Country of Origin: Canada
  • Depth: 77.5 mm
  • Display Type: Colour TFT LCD
  • IsSustainable: Yes
  • Number of Outputs: 1 Pulse
  • Weight: 871 g
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Features
    • Fast access to timely, critical information for energy, electrical network, and asset management
    • Help operations personnel avoid downtime by making power quality understandable
    • Makes energy and power quality actionable to support your op and sustainability goals
    • More detailed PQ compliance reporting, and expert level power quality and root cause analytics
    • Forecasting to help ensure your electrical system avoid overloads, unbalances or high peak demand
    • Ensure energy efficiency and optimized costs by understanding how energy is being consumed
    • Perform sub billing or allocate cost to encourage energy efficient behavior, reduce PF penalties
    • Support participation in demand response or variable tariff (TOU, RTP) programs
    • Maximize use of capacity by performing load studies and infrastructure expansion planning
    • Patented ION Programming allows for full alarm/calc customization, control and more
  • Communications & Management Attributes
    • Communication Port Protocol : Modbus RTU 115 kbauds - 2-wire, ION 115 kbauds - 2-wire, DNP3, IEC 61850, Modbus TCP/IPEthernet Modbus TCP/IP daisy chain 10/100 Mbit/s, RSTP 801.1d 2004
    • Communication Service : SMTP e-mail notification, RSTP support, NTP time synchronization, DHCP, PTP time synchronization
    • Communication Network Type : IPv6 (internet protocol)
    • Communication Port Support : ETHERNETscrew terminal block RS485
  • Complementary Attributes
    • Line Rated Current : 1 A, 5 A, 10 A
    • Us Rated Supply Voltage : 90...415 V AC 45...65 Hz +/- 10 %110...415 V DC +/- 10 %
  • Important Information Attributes
    • Cybersecurity : enable/disable communication ports, password protection, Syslog protocol support, robust security logs, port hardening
    • Data Recording : min/max of instantaneous values, waveform logs, sequence of event recording, time stamping, alarm logs, trending/forecasting, sag and swell logs, harmonics logs, GPS synchronisation, data logs, event logs, 64 data recorders
    • Device Application : power monitoring, WAGES metering
    • Electromagnetic Compatibility : electrostatic discharge conforming to IEC 61000-4-2radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3electrical fast transient/burst immunity test conforming to IEC 61000-4-4surge immunity test conforming to IEC 61000-4-5conducted RF disturbances conforming to IEC 61000-4-6magnetic field at power frequency conforming to IEC 61000-4-8voltage dips and interruptions immunity test conforming to IEC 61000-4-11immunity to impulse waves conforming to IEC 61000-4-12, conducted and radiated emissions (2...150 Hz) conforming to EN 55022, conducted and radiated emissions conforming to EN 55011, conducted and radiated emissions conforming to FCC part 15, conducted and radiated emissions conforming to ICES-003, conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579surge withstand conforming to IEEE C37.90.1
    • Information Displayed : voltage, current, frequency, power, energy consumption, harmonic distortion
    • Isolation Voltage : III400-690 V conforming to IEC 61010-1:ed. 3, III400-690 V conforming to EN 61010-1:ed. 3III347-600 V conforming to UL 61010-1:ed. 3, III347-600 V conforming to CSA C22.2 No 61010-1:ed. 3
    • Market Segment : buildings large building network management: main incomerbuildings large building network management: sub feederbuildings multi-site network management: sub feeder, data center small building network management: sub feederhealthcare multi-site network management: sub feeder, industry network management: sub feeder, buildings large building cost management: billing: sub feeder, buildings small building network management: main incomer, buildings medium building network management: main incomer, buildings multi-site network management: main incomer, data center network management: main incomer, healthcare large building network management: main incomer, industry multi-site network management: main incomer, utility network management: sub feeder
    • Measurement Accuracy : current +/- 0.1 %, voltage +/- 0.1 %active energy +/- 0.2 %
    • Network Frequency : 50 Hz, 60 Hz
    • Number Of Poles : + N, 3P, 1P + N
    • Power Quality Analysis : EN 50160 2010 compliance reportIEEE 519 2014 compliance report, IEC 61000-4-30 class A power quality measurement, up to the 63rd harmonicIEC 61000-4-15 harmonic distortion, EN 50160 2010 waveform capture, IEEE 519 2014 voltage sag and swell detection, programmablity (logic and math functions)IEC 62586 power quality monitoring, disturbance direction detection, IEC 61000-4-15 flicker, rapid voltage change
    • Type Of Measurement : active and reactive power per phase, rmsapparent power per phase, rmspower factor per phase, rms, current per phase, rms, voltagefrequency total, active and reactive power total, apparent power total, power factor total
    • Web Services : customizable home page, file upload/download via FTP, file upload/download via SFTP, web server, alarm notification by e-mail, viewing of captured waveform (FTP), viewing of captured waveform (web), HTTPS server
    • Certificate Agency : CE, cULus, N998
    • Carbon Footprint Of The Distribution Phase A4 : 0.3761219657477814, 0.4 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 2 kg CO2 eq., 1.783677042218933
    • Carbon Footprint Of The Installation Phase A5 : 0.02442844100471966, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 97 kg CO2 eq., 96.62330961493974
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 199 kg CO2 eq., 199.2820090070477
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-09-08
    • Return Indicator : Y
    • Device Type : Relay, Control & Measurement - measuring, monitoring device
    • Serviceability : No
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2508020EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2345
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 7
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Dangerous Goods Code : LITHIUM METAL BATTERIES IN EQUIP. BUTTON CELL-BAT EXEMPT
    • Product Kit Identifier : N
    • Compatibility Code : PM8240
    • Device Short Name : PM8340
    • Display Resolution : 320 x 240 pixels QVGA
    • Display Type : colour TFT LCD
    • Energy Efficiency Optimized : False
    • Frequency Measurement Range : 42-69 Hz
    • Installation Category : III
    • Measurement Current : 50-10000 mA
    • Measurement Voltage : 57-400 V AC 42...69 Hz between phase and neutral100-690 V AC 42...69 Hz between phases
    • Memory Capacity : 512 MB
    • Mounting Mode : flush-mounted
    • Mounting Support : framework
    • Power Consumption In Va : 16 VA 230 V AC
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Name : PowerLogic PM8000
    • Product Or Component Type : power meter
    • Range : PowerLogic
    • Returnability : Yes
    • Sampling Rate : 512 samples/cycle
    • Software Version : v6.2.4
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 298 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Database Version : 2024-01
    • Data Source : extrapolated product
    • Height Nominal : 96 mm
    • Width Nominal : 96 mm
    • Nbr. Of Units In Pkg. : 1
    • Customs Code : 9028300000
    • Warranty In Months : 18
    • Functional Unit Description : Technical data:& 10Supply Voltage& 1090...415 V AC 45...65 Hz +/- 10 %& 10110...415 V DC +/- 10 %& 10Measurement voltage& 1057…400 V AC 42...69 Hz between phase and neutral& 10100…690 V AC 42...69 Hz between phases& 10Measurement current& 1050…10000 mA
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Reference Lifetime In Y : 10
    • Energy Consumption On Product Lifetime In Kwh : 414.348
    • Recyclability Potential In % : 17
  • Environment Attributes Main
    • Ambient Air Temperature For Storage : -40-85 °C, -40-85 °C
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Carbon Footprint : 298.0895460709589
    • Ambient Air Temperature For Operation : -25-70 °C-25-70 °C
    • Circularity Profile : ENVEOLI2508020EN
    • Environmental Disclosure : ENVPEP2508020EN
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP54 front: conforming to IEC 60529IP30 body: conforming to IEC 60529
    • Operating Altitude : 9842.52 ft (3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 5-95 %
    • Pep Code : ENVPEP2508020EN
    • Pep Verification Date : 2025-09-15
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : power meter
  • ETIM
    • ETIM 8 : EC002301
    • ETIM 9 : EC002301
    • ETIM 10 : EC002301
  • Output Attributes
    • Number Of Outputs : 1 pulse
  • Input Attributes
    • Analogue Input Type : voltage (impedance 5 MOhm)current (impedance 0.3 mOhm)
    • Number Of Inputs : 3 digital 30 V AC3 digital 60 V DC
  • Specifications
    • Country of Origin : Canada
    • Weight : 871 g
    • Depth : 77.5 mm