SQUARE D

Power quality meter, PowerLogic ION7400, Advanced, integrated display, 512 MB, 512 s/c

Power quality meter, PowerLogic ION7400, Advanced, integrated display, 512 MB, 512 s/c

SQDMETSEION7400A METSEION7400A 3606486874905
20601.13 / EA
http://schema.org/OutOfStock
  • Depth: 78.5 mm
  • Display Type: Colour TFT LCD
  • IsSustainable: Yes
  • Number of Outputs: 1 Pulse
  • Weight: 954 g
QTY
  • Features
  • Specifications
  • Features
    • Fast access to timely, critical information for energy, electrical network, and asset management
    • More detailed PQ compliance reporting, and expertlevel power quality and rootcause analytics
    • Forecasting to help ensure your electrical system avoid overloads, unbalances or high peak demand
    • Ensure energy efficiency and optimized costs by understanding how energy is being consumed
    • Perform subbilling or allocate cost to encourage energyefficient behavior, reduce PF penalities
    • Support participation in demand response or variable tariff (TOU, RTP) programs
    • Maximize use of capacity by performing load studies and infrastructure expansion planning
    • Patented ION Programming allows for full alarm/calc customization, control and more
  • Prop 65
    • WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
  • Communications & Management Attributes
    • Communication Port Protocol : Modbus RTU 115 kbauds - 2-wire, ION 115 kbauds - 2-wire, DNP3IEC 61850 10/100 Mbit/s, Modbus TCP/IP, Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s, RSTP 801.1d 2004, Ansi C12.19, DLMS 115 kbauds - 2-wire
    • Communication Service : DHCP, RSTP support, NTP time synchronization, SMTP e-mail notification, PTP time synchronization
    • Communication Network Type : IPv6 (internet protocol)
    • Communication Port Support : ETHERNETscrew terminal block RS485optical probe fiber opticmini B USB USB
  • Complementary Attributes
    • Line Rated Current : 10 A, 5 A, 1 A
    • Us Rated Supply Voltage : 90...415 V AC 45...65 Hz +/- 10 %110...415 V DC +/- 10 %
  • Important Information Attributes
    • Cybersecurity : Syslog protocol support, robust security logs, enable/disable communication ports, password protection, port hardening
    • Data Recording : alarm logs, waveform logs, sequence of event recording, event logs, sag and swell logs, data logs, harmonics logs, GPS synchronisation, time stamping, trending/forecasting, min/max of instantaneous values, 64 data recorders
    • Device Application : revenue billing, WAGES metering, data aggregation, power monitoring
    • Electromagnetic Compatibility : electrostatic discharge conforming to IEC 61000-4-2radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3electrical fast transient/burst immunity test conforming to IEC 61000-4-4surge immunity test conforming to IEC 61000-4-5conducted RF disturbances conforming to IEC 61000-4-6magnetic field at power frequency conforming to IEC 61000-4-8, voltage dips and interruptions immunity test (2...150 Hz) conforming to IEC 61000-4-11immunity to impulse waves conforming to IEC 61000-4-12conducted and radiated emissions conforming to EN 55022, conducted and radiated emissions conforming to EN 55011, conducted and radiated emissions conforming to FCC part 15, conducted and radiated emissions conforming to ICES-003, conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579surge withstand conforming to IEEE C37.90.1
    • Information Displayed : voltage, current, frequency, power, energy consumption, harmonic distortion
    • Isolation Voltage : III400-690 V conforming to IEC 61010-1:ed. 3, III400-690 V conforming to EN 61010-1:ed. 3III347-600 V conforming to UL 61010-1:ed. 3, III347-600 V conforming to CSA C22.2 No 61010-1:ed. 3
    • Measurement Accuracy : current +/- 0.1 %, voltage +/- 0.1 %active energy +/- 0.2 %
    • Network Frequency : 50 Hz, 60 Hz
    • Number Of Poles : 1P + N, 3P, 3P + N
    • Power Quality Analysis : EN 50160 compliance report, IEC 61000-4-30 class A power quality measurement, up to the 63rd harmonic, harmonic distortion, waveform captureIEC 61000-4-15 voltage sag and swell detectionIEC 62586 programmablity (logic and math functions), IEC 62586 power quality monitoring, IEC 61000-4-15 flicker, IEC 61000-4-30 class A disturbance direction detection, rapid voltage change
    • Type Of Measurement : active and reactive power per phase, rmsapparent power per phase, rmspower factor per phase, rms, current per phase, rms, voltage per phase, rms, frequencyactive and reactive power total, apparent power total, power factor total, active and reactive energy, apparent energy
    • Web Services : customizable home page, file upload/download via FTP, file upload/download via SFTP, web server, alarm notification by e-mail, viewing of captured waveform (FTP), viewing of captured waveform (web), HTTPS server
    • Certificate Agency : CE, cULus, N998
    • Carbon Footprint Of The Distribution Phase A4 : 2.288449939197264, 2 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 2 kg CO2 eq., 2.354316872709171
    • Carbon Footprint Of The Installation Phase A5 : 0.006420220073525087, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 62 kg CO2 eq., 62.471819921736106
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 142 kg CO2 eq., 142.0521727305075
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-10
    • Return Indicator : N
    • Device Type : Relay, Control & Measurement - measuring, monitoring device
    • Serviceability : No
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1512006_V2
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2333
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 7
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Dangerous Goods Code : LITHIUM METAL BATTERIES IN EQUIP. BUTTON CELL-BAT EXEMPT
    • Product Kit Identifier : N
    • Device Short Name : ION7400
    • Display Resolution : 320 x 240 pixels QVGA
    • Display Type : colour TFT LCD
    • Energy Efficiency Optimized : False
    • Frequency Measurement Range : 42-69 Hz
    • Installation Category : III
    • Measurement Current : 50-10000 mA
    • Measurement Voltage : 57-400 V AC 42...69 Hz between phase and neutral100-690 V AC 42...69 Hz between phases
    • Memory Capacity : 512 MB
    • Mounting Mode : flush-mounted
    • Mounting Support : framework
    • Power Consumption In Va : 18 VA 415 V AC
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Name : PowerLogic ION7400
    • Product Or Component Type : power meter
    • Range : PowerLogic
    • Returnability : No
    • Sampling Rate : 512 samples/cycle
    • Software Version : v6.2.4
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 209 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Database Version : 2024-01
    • Data Source : extrapolated product
    • Height Nominal : 112 mm
    • Width Nominal : 98 mm
    • Nbr. Of Units In Pkg. : 1
    • Customs Code : 9028300000
    • Warranty In Months : 18
    • Functional Unit Description : To measure energy consumption and display the information on a screen, capable of operating within the following electrical parameters:& 10The ION7400 Power Meter operates within voltage ranges of 90-415V (50/60Hz) at <lt/>36VA, 90-120V (400Hz) at <lt/>28VA, and 120-300V at 17W, with current ratings of 1A for 0.5 seconds and 5A for 0.2 seconds, designed for 10 years of use at a 100% rate, consuming 5W in active mode (10% of the time) and 4W in standby mode (90% of the time), all in compliance with relevant standards.
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Reference Lifetime In Y : 10
    • Energy Consumption On Product Lifetime In Kwh : 414.348
    • Recyclability Potential In % : 4
  • Environment Attributes Main
    • Ambient Air Temperature For Storage : -40-85 °C, -40-85 °C
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Carbon Footprint : 209.17317968422356
    • Ambient Air Temperature For Operation : -25-70 °C-25-70 °C
    • Circularity Profile : ENVEOLI1512006_V2
    • Environmental Disclosure : ENVPEP1512006EN
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP54 front: conforming to IEC 60529IP30 body: conforming to IEC 60529
    • Operating Altitude : 9842.52 ft (3000 m)
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 5-95 %
    • Pep Code : ENVPEP1512006EN
    • Pep Verification Date : 2025-03-21
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : power meter
  • ETIM
    • ETIM 8 : EC002301
    • ETIM 9 : EC002301
    • ETIM 10 : EC002301
  • Output Attributes
    • Number Of Outputs : 1 pulse
  • Input Attributes
    • Analogue Input Type : voltage (impedance 5 MOhm)current (impedance 0.3 mOhm)
    • Number Of Inputs : 3 digital 30 V AC3 digital 60 V DC
  • Specifications
    • Country of Origin : Brazil, Canada, Costa Rica, France, United States
    • Weight : 954 g
    • Depth : 78.5 mm