SQUARE D

DIN rail meter, PowerLogic EM3570, Ethernet, LVDC, LVCT input bundled with external Power Supply

DIN rail meter, PowerLogic EM3

SQDMETSEEM3570 METSEEM3570 3606481096494
2312.17 / EA
http://schema.org/OutOfStock
  • Depth: 70.6 mm
  • Number of Outputs: 1 Relay Output
The EM3570 series offer a three-phases DIN rail-mounted energy meters fitted for accurate cost allocation and sub-metering. EM3570 models are designed for use with Low Votage Current Transducers 1/3Volt or 1Volt output. Current input from 5A to 32000A, according to the LVCT configuration in the HMI (CTs must be rated for use with Class 1 voltage inputs). Bidirectional monitoring supports both upstream and downstream power flow, critical for renewable energy applications. BACnet/IP, Modbus TCP/ IP and SNMP come native, along with Dual Ethernet ports for daisy chain for good versatility and flexibility. Product need to be supplied by a 24VDC source. Two digital inputs support status monitoring, pulse counting, multi tariff and partial resets. Relay output for alarm notification. Product dimensions are as follows: width 90 mm, depth 70 mm, height 91 mm. Compliant with the standards IEC 61010-1:2010, UL61010-1:2019, IEC/UL 61010-2-30, CSA C22.2 No. 61010-1-12, CSA C22.2 No. 61010-2-030. Meter need to be supplied in 24VDC, no voltage transformer included. The PowerLogic EM3570 supports IPv6 and network auto-detection. It comes with embedded web pages that display real time data, usage peaks and alarm status. Designed with cybersecurity in mind, it also allows full configuration of all network services.
QTY
  • Product Description
  • Features
  • Specifications
The EM3570 series offer a three-phases DIN rail-mounted energy meters fitted for accurate cost allocation and sub-metering. EM3570 models are designed for use with Low Votage Current Transducers 1/3Volt or 1Volt output. Current input from 5A to 32000A, according to the LVCT configuration in the HMI (CTs must be rated for use with Class 1 voltage inputs). Bidirectional monitoring supports both upstream and downstream power flow, critical for renewable energy applications. BACnet/IP, Modbus TCP/ IP and SNMP come native, along with Dual Ethernet ports for daisy chain for good versatility and flexibility. Product need to be supplied by a 24VDC source. Two digital inputs support status monitoring, pulse counting, multi tariff and partial resets. Relay output for alarm notification. Product dimensions are as follows: width 90 mm, depth 70 mm, height 91 mm. Compliant with the standards IEC 61010-1:2010, UL61010-1:2019, IEC/UL 61010-2-30, CSA C22.2 No. 61010-1-12, CSA C22.2 No. 61010-2-030. Meter need to be supplied in 24VDC, no voltage transformer included. The PowerLogic EM3570 supports IPv6 and network auto-detection. It comes with embedded web pages that display real time data, usage peaks and alarm status. Designed with cybersecurity in mind, it also allows full configuration of all network services.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Communications & Management Attributes
    • Communication Port Protocol : Modbus TCP/IP, BACnet IP, HTTPS, SNMP, SNTP, Link Layer Discovery Protocol
    • Communication Port Support : RJ45
    • Communication Service : Syslog protocol support
  • Physical Attributes
    • Buffer Size : 16-bit 10
    • Color : White
  • Complementary Attributes
    • Rated Voltage : 90-347 V phase to neutral (L-N))156-600 V phase to phase (L-L))
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SC, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician, System Integrator
    • Market Segmentation Id : RESIDENTIAL, COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Residential, Commercial, Industrial
    • Data Recording : energy consumption logs, time stamping, data logs
    • Device Application : partial meter, sub billing, multi-tariff
    • Function Available : external synchronisation to communication, sliding/fixed/rolling block
    • Information Displayed : status and alert, communication IP address, input/output status, error, alarms, instant power per usage, firmware info, configurable summary page (average, total, demand, nominal values)
    • Local Signalling : Orange LED alarm / energy, Green flashing LED operating state
    • Measurement Accuracy : active energy +/- 0.5 %reactive energy +/- 2 %, reactive power +/- 2 %, apparent energy +/- 0.5 %, apparent power +/- 0.5 %power factor +/- 0.005, frequency +/- 0.5 %, voltage +/- 0.5 %, current +/- 0.5 %
    • Metering Type : peak demand power PM, QM, SM, current I1, I2, I3, Iavg, active, reactive, apparent energy (signed, four quadrant), demand power P, Q, S, voltage U21, U32, U13, V1, V2, V3, calculated neutral current
    • Network Frequency : 60 Hz +/- 10 %, 50 Hz +/- 10 %
    • Number Of Poles : + N, 2P + N, 1P + N, 3P
    • Tightening Torque : current circuit: 0.8-0.8 N.mvoltage circuit: 0.5-0.5 N.m, input circuit: 0.5-0.5 N.m, supply circuit: 0.8-0.8 N.m, relay output: 0.8-0.8 N.m
    • Type Of Measurement : apparent power per phasepower factor per phaseactive and reactive power total, active and reactive power per phase, apparent power total, power factor total, peak demand power, current, voltage, frequency, starting current selection range
    • Web Services : real time viewing of data, network and protocol setting, data and time, IP filtering
    • Certificate Agency : CE, UKCA, cULus, BTL
    • [Ue] Rated Operational Voltage : 125...300 V DC external module, 90...600 V AC 50/60 Hz external module
    • Connections - Terminals : current circuit screw terminals 6-6 mm²voltage circuit screw terminals 1.5-1.5 mm², input circuit screw terminals 6-6 mm²supply circuit screw terminals 4-4 mm², relay output screw terminals 1.5-1.5 mm²
    • Carbon Footprint Of The Distribution Phase [A4] : 0.0554793989, 0.1 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 0.3 kg CO2 eq., 0.3119497268
    • Carbon Footprint Of The Installation Phase [A5] : 0.0045418652, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 84 kg CO2 eq., 84.2455373406
    • Carbon Footprint Of The Use Phase [B2 B3 B4 B6] : 438 kg CO2 eq., 438.3219518272
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-06-18
    • Pre Comm Date : 2024-08-20
    • Return Indicator : Y
    • Stocking Flag : Y
    • Stock Policy : 1
    • Device Type : Relay, Control & Measurement - measuring, monitoring device
    • Serviceability : No
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2103001_V1
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2108
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 4
    • With Recycled Cardboard : No
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Dangerous Goods Code : LITHIUM METAL BATTERIES IN EQUIP. BAT : ≤ 2g AND ≤ 2 BAT
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Device Short Name : EM3570
    • Display Digits : 5
    • Display Resolution : 126 x 94 pixels
    • Display Type : Backlit LCD
    • Energy Efficiency Optimized : False
    • Measurement Current : 1-32767 A
    • Memory Capacity : 32 GB
    • Mounting Mode : clip-on
    • Mounting Support : DIN rail
    • Power Consumption In W : 5 W
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Name : PowerLogic EM3570
    • Product Or Component Type : energy meter
    • Range : PowerLogic
    • Returnability : Yes
    • Service Life : 15 year(s) 45 °C 60% RH
    • Software Version : EIME v5.8.1
    • Sustainable Packaging : No
    • Tamperproof Of Settings : protected by access code
    • Technology Type : electronic
    • Total Lifecycle Carbon Footprint : 523 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Pep Code : ENVPEP2103001EN
    • Database Version : 2016-11
    • Pep Verification Date : 2021-03-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional-unit Description : 1.Bidirectional Energy measurement, External current sensors, Supports Multi tariff, Demand Low-voltage DC control power& 102.AC/DC Power Supply with 24Vdc Output
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unité (unit)
    • Reference Lifetime In Y : 10
    • Energy Consumption On Product Lifetime In Kwh : 578.16
    • Energy Model - Manufacturing [A1-a3] : Energy model used: INDIA
    • Energy Model - Installation [A5] : Electricity mix; AC; consumption mix, at consumer; 120V; US / Electricity mix; AC; consumption mix, at consumer; 220V; CN / Electricity mix; AC; consumption mix, at consumer; 220V - 230V; RER
    • Energy Model - Use [B6] : Electricity mix; AC; consumption mix, at consumer; 120V; US / Electricity mix; AC; consumption mix, at consumer; 220V; CN / Electricity mix; AC; consumption mix, at consumer; 220V - 230V; RER
    • Energy Model - End Of Life [C1-c4] : Electricity mix; AC; consumption mix, at consumer; 120V; US / Electricity mix; AC; consumption mix, at consumer; 220V; CN / Electricity mix; AC; consumption mix, at consumer; 220V - 230V; RER
    • Height Nominal : 91.4 mm
    • Width Nominal : 126 mm
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 522.000 g
    • Take-back : No
    • Warranty (In Months) : 18
    • Customs Code : 9028300000
    • Other Technical Guide Name : PLSED310190EN
  • Environment Attributes Main
    • Ambient Air Temperature For Storage : -40-85 °C, -40-85 °C
    • Operating Altitude : <= 9842.52 ft (3000 m), <= 9842.52 ft (3000 m)
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 522.9394601588
    • Ambient Air Temperature For Operation : -25-70 °C-25-70 °C
    • Circularity Profile : ENVEOLI2103001_V1
    • Environmental Disclosure : ENVPEP2103001EN
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP20 meter:IP40 display:
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 5-95 %
    • Pep Code : ENVPEP2103001EN
    • Pep Verification Date : 2021-03-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : energy meter
  • ETIM
    • ETIM 8 : EC001506
    • ETIM 9 : EC001506
  • Output Attributes
    • Number Of Outputs : 1 relay output
  • Input Attributes
    • Analogue Input Type : low voltage current transformer 0.333 V or 1 V
    • Number Of Inputs : 2 digital
  • Specifications
    • Country of Origin : India, Philippines, Singapore, United States
    • Depth : 70.6 mm