SQUARE D

BCPM power monitoring basic - 42 solid core 100 A - 18 mm CT spacing

BCPM power monitoring basic -

SQDBCPMC242S BCPMC242S SQDBCPMC242S
0.00 / EA
http://schema.org/OutOfStock
  • Certifications: UL
  • Height: 146 mm
  • Mounting Type: Panel-mounted
  • Net Weight: 1.5 kg
  • Standard: ANSI C12.1, EN 61010, IEC 61036, UL 508
  • Storage Temperature: -40-70 °C
  • Width: 288 mm
This is an integrated solution for monitoring multi-circuits and mains by using a single meter. The meter is designed for use in new build and is used for critical power operations in data centres and energy management in buildings. It offers class 1 (1 %) power and energy system accuracy (100A solid core current transformers) on all branch channels. The BCPM monitors only the 42 branch circuits current. All to provide information on the complete Power Distribution Unit. Full alarming capabilities ensure that potential issues are dealt with before they become problems. Communication enabled with a RS485 serial port and the Modbus protocol support, more communication options with the gateway H8951. The meter need to be powered by a 90V AC to 277V AC supply source. Include 2 21-CTs board strips with 18mm spacing between each CT connectors, for 42 circuits. The device dimensions are 228mm in width, 146mm in height and weight 1.5 kilograms.
QTY
  • Product Description
  • Specifications
This is an integrated solution for monitoring multi-circuits and mains by using a single meter. The meter is designed for use in new build and is used for critical power operations in data centres and energy management in buildings. It offers class 1 (1 %) power and energy system accuracy (100A solid core current transformers) on all branch channels. The BCPM monitors only the 42 branch circuits current. All to provide information on the complete Power Distribution Unit. Full alarming capabilities ensure that potential issues are dealt with before they become problems. Communication enabled with a RS485 serial port and the Modbus protocol support, more communication options with the gateway H8951. The meter need to be powered by a 90V AC to 277V AC supply source. Include 2 21-CTs board strips with 18mm spacing between each CT connectors, for 42 circuits. The device dimensions are 228mm in width, 146mm in height and weight 1.5 kilograms.
  • Complementary
    • Communication Port Support : RS485
    • Connection Pitch : 18 mm
    • Measurement Accuracy : current 2 % 0.25…2 A || current 1 % 2…100 A
    • Measurement Voltage : 90-277 V phase to neutral || 150-480 V phase to phase
    • Sampling Rate : 256 samples/cycle
    • Communication Port Protocol : Modbus RTU
    • Update Time : 1.8 s
    • Analogue Input Type : solid core CT 100 A42 x
    • Communication Of Data : low-low current alarm || low current alarm || high current alarm || high-high current alarm
    • Provided Equipment : 42 x current transformer || 2 x cables
  • Environment
    • Height : 146 mm
    • Mounting Mode : panel-mounted
    • Ambient Air Temperature For Storage : -40-70 °C
    • Relative Humidity : 0-95 % 0-60 °C
    • Standards : UL 508 || EN 61010 || IEC 61036 || ANSI C12.1
    • Mounting Support : enclosure || panel
    • Product Certifications : UL
    • Width : 288 mm
    • Net Weight : 1.5 kg
    • Operating Altitude : 9842.52 ft (3000 m)
  • Specifications
    • Network Frequency : 50 Hz || 60 Hz
    • Energy Management : sub billing and cost allocation
    • [Us] Rated Supply Voltage : 90...277 V AC 50/60 Hz +/- 1 %
    • Variant : basic
    • Type Of Measurement : current
    • Power Monitoring : basic instrumentation
    • Product Or Component Type : multi-circuit energy meter
    • Product Name : PowerLogic BCPM
    • Device Application : sub billing
    • Device Short Name : BCPMC
    • Range : PowerLogic
  • Offer Sustainability
    • China Rohs Regulation : X
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Eu Rohs Directive : Compliant with Exemptions
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.