iEM3355 energy meter - 125 A - Modbus - 1 digital I - 1 digital O - multi-tariff - MID

TRIPHASE KWK METER 125A MODBUS

SQDA9MEM3355 A9MEM3355 3606480696428
818.21 / EA
http://schema.org/OutOfStock
  • Depth: 69.3 mm
  • Display Type: LCD Display
  • Number of Outputs: 1 Digital (static)
  • Output Voltage: ...40 V, 50 mA
The Acti9 iEM3000 series energy meters offer an attractive range of three-phase DIN rail-mounted energy meters with an LCD display. Additional local signaling includes green LED power-on indicator, flashing yellow LED for accuracy checking, an overload alarm and communication indicators. This meter can be used in sub-billing applications and supports 4 tariff schedules. The meter provides the following accuracy classes: Active Energy: class 1 per IEC 62053-21, Active Energy: class B per EN 50470-3 and Active Energy: class 1 per IEC 61557-12. The meter will measure Active and Reactive Power, Active and Reactive Energy, Voltage and Current. With four quadrant Energy measurement. Designed for 50Hz or 60Hz networks, supply voltage can range from 100 to 277VAC or 173 to 480VAC. Line rated current for this meter is up to 125A via direct connect and will support Single Phase and Neutral, Three Phase and Three Phase and Neutral configurations. Communication protocol is Modbus with screw terminal support. There is one programmable digital input and one programmable digital output that can be used as a pulsed output. Certifications include EAC, CE, UL and MID. Product dimensions are as follows: width 4.96 in (126 mm), depth 2.72in (69 mm), height 4.1 in (103 mm) and product weight 9.17 oz (260 g). Compatible with power management software to take advantage of the IoT digital power installation.
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
  • Communications & Management Attributes
    • Communication Port Protocol : Modbus RTU 9.6, 19.2 and 38.4 kbauds even/odd or none 4000 V
    • Communication Port Support : screw terminal block RS485
  • Physical Attributes
    • Color : White
  • Complementary Attributes
    • Rated Voltage : 100-277 V, 173-480 V
    • Line Rated Current : 125 A
    • Maximum Value Measured : 99999999.9 kWh
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SC, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician, System Integrator
    • Market Segmentation Id : RESIDENTIAL, COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Residential, Commercial, Industrial
    • Device Application : multi-tariff, sub billing, partial meter
    • Information Displayed : tariff 4)
    • Local Signalling : Green indicator light power ON, Yellow flashing LED accuracy checking, alarm overload, Yellow indicator light communications are active on the Modbus port (Modbus)
    • Market Segment : buildings medium building cost management: billing: sub feeder, buildings medium building cost management: billing: panelboard, buildings large building cost management: billing: sub feeder, buildings large building cost management: billing: panelboard, buildings multi-site cost management: billing: sub feeder, buildings multi-site cost management: billing: panelboard, buildings small building cost management: cost allocation: sub feeder, buildings small building cost management: cost allocation: panelboard, buildings medium building cost management: cost allocation: main incomer, buildings medium building cost management: cost allocation: sub feeder, buildings medium building cost management: cost allocation: panelboard, buildings large building cost management: cost allocation: main incomer, buildings large building cost management: cost allocation: sub feeder, buildings large building cost management: cost allocation: panelboard, buildings multi-site cost management: cost allocation: main incomer, buildings multi-site cost management: cost allocation: sub feeder, buildings multi-site cost management: cost allocation: panelboard, data center cost management: cost allocation, healthcare cost management: cost allocation, industry cost management: cost allocationbuildings small building cost management: billing: main incomer, buildings small building cost management: billing: sub feeder, buildings small building cost management: billing: panelboard, buildings medium building cost management: billing: main incomer, buildings large building cost management: billing: main incomer, buildings multi-site cost management: billing: main incomer, data center cost management: billing, healthcare cost management: billing, industry cost management: billing, buildings small building cost management: cost allocation: main incomer
    • Network Frequency : 50 Hz, 60 Hz
    • Poles Description : 3P + N, 1P + N, 3P
    • Type Of Measurement : active and reactive energy, active and reactive power, current, voltage
    • Connections Terminals : screw terminals 50-50 mm²
    • Carbon Footprint Of The Distribution Phase A4 : 0.13324, 0.1 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.83364, 0.8 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0.1 kg CO2 eq., 0.13339
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 12 kg CO2 eq., 12.45
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 52 kg CO2 eq., 52.475
    • Certificate Agency : MID EN 50470-1 sub-meter)CE IEC 61010-1 safety), CE EN 61557-12 power monitor), CE EN/IEC 61326-1 EMC), UKCA BS EN 61010-1 safety), UKCA BS EN 61557-12 power monitor), UKCA BS EN 61326-1 EMC), cULus UL 61010-1 safety), cULus EN 61010-1 safety), EAC EN 50470-3 sub-meter), RCM EN 62052 sub-meter), KZ EN 50470-3 sub-meter), METAS EN 50470-1 sub-meter), MID EN 50470-3 sub-meter), NMI NMI M 6-1
    • Other Technical Guide : https://download.schneider-electric.com/files?p_Doc_Ref=PLSED310049EN&p_File_name=PLSED310049EN_Web.pdf, PLSED310049EN
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-06-18
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Device Type : Relay, Control & Measurement - measuring, monitoring device
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : DPIBS
    • Average Life Duration : 15 year(s)
    • Manufacturing Carbon Footprint : 12.45
    • Use Carbon Footprint : 52.475
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1404007_V2
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 1201
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 7
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Compatibility Code : iEM3355
    • Device Short Name : iEM3355
    • Display Type : LCD display
    • Energy Efficiency Optimized : False
    • Halogen Free Status : Halogen free plastic parts product
    • Measurement Current : 0-125 A
    • Metering Type : active, reactive, apparent energy (signed, four quadrant)
    • Mounting Mode : clip-on
    • Mounting Support : DIN rail
    • Overvoltage Category : III
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Name : Acti9 iEM3000
    • Product Or Component Type : energy meter
    • Range : Acti9
    • Returnability : No
    • Sampling Rate : 32 samples/cycle
    • Software Version : v5.9.4
    • Sustainable Packaging : No
    • Technology Type : electronic
    • Total Lifecycle Carbon Footprint : 66 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Warranty In Months : 18
    • Pep Code : ENVPEP1404007EN
    • Database Version : 2022-01
    • Pep Verification Date : 2025-03-18
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent external review
    • Data Source : referent product
    • Functional-unit Description : This is a energy measuring meter which can measure 125 A current with Modbus protocol,1 digital input and 1 digital Output feature for service life of 10 years& 10Dimensions: H103.2mm x L126mm x D69.3mm& 10IP40 front panel: conforming to IEC 60529& 10IP20 body: conforming to IEC 60529
    • Functional-unit Quantity : 1
    • Functional-unit Unit : EACH
    • Reference Lifetime, In Y : 10
    • Energy Consumption On Product Lifetime, In Kwh : 124.83
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Production mix; Low voltage; CN
    • Energy Model - Installation [A5] : Electricity Mix; Production mix; Low voltage; UE-27
    • Energy Model - Use [B6] : Electricity Mix; Production mix; Low voltage; UE-27
    • Energy Model - End Of Life [C1-c4] : Electricity Mix; Production mix; Low voltage; UE-27
    • Recyclability Potential, In % : 32
    • Offer Owner Code : 190781
    • Pn : 1
    • Height Nominal : 103.2 mm
    • Width Nominal : 126 mm
    • Climate Change - Fossil Fuels ( Kg Co2 Eq.) Manufacturing [A1-a3] : 12.313
    • Climate Change - Fossil Fuels ( Kg Co2 Eq.) Operational Energy Use [B6] : 52.414
    • Climate Change - Fossil Fuels ( Kg Co2 Eq.) Benefits/Loads Beyond System Boundaries [D] : -2.3688
    • Climate Change - Total ( Kg Co2 Eq.) Manufacturing [A1-a3] : 12.45
    • Climate Change - Total ( Kg Co2 Eq.) Operational Energy Use [B6] : 52.475
    • Climate Change - Total ( Kg Co2 Eq.) Benefits/Loads Beyond System Boundaries [D] : -2.4078
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Total Life Cycle : 1440.2725
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Manufacturing [A1-a3] : 161.56
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Distribution [A4] : 1.6179
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Installation [A5] : 1.3886
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Operational Energy Use [B6] : 1259.4
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) End Of Life [C1-c4] : 16.306
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Benefits/Loads Beyond System Boundaries [D] : -49.965
    • Ecotoxicity (Fresh Water) (Ctue) Manufacturing [A1-a3] : 184.11
    • Ecotoxicity (Fresh Water) (Ctue) Operational Energy Use [B6] : 620.81
    • Ecotoxicity (Fresh Water) (Ctue) End Of Life [C1-c4] : 178.94
    • Ecotoxicity (Fresh Water) (Ctue) Benefits/Loads Beyond System Boundaries [D] : -44.639
    • Hazardous Waste Disposed Of (Kg) Manufacturing [A1-a3] : 42.367
    • Hazardous Waste Disposed Of (Kg) Benefits/Loads Beyond System Boundaries [D] : -64.486
    • Impacts Related To Land Use/Soil Quality (-) End Of Life [C1-c4] : 1.8143
    • Ionizing Radiation, Human Health (Kbq Of U235 Equiv.) Manufacturing [A1-a3] : 827.65
    • Ionizing Radiation, Human Health (Kbq Of U235 Equiv.) Operational Energy Use [B6] : 67.037
    • Ionizing Radiation, Human Health (Kbq Of U235 Equiv.) Benefits/Loads Beyond System Boundaries [D] : -42.422
    • Net Use Of Fresh Water (M3) End Of Life [C1-c4] : 1.8428
    • Non-hazardous Waste Disposed Of (Kg) Manufacturing [A1-a3] : 4.5218
    • Non-hazardous Waste Disposed Of (Kg) Operational Energy Use [B6] : 7.79
    • Non-hazardous Waste Disposed Of (Kg) Benefits/Loads Beyond System Boundaries [D] : -3.5851
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Total Life Cycle : 5.5715
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Manufacturing [A1-a3] : 5.5715
    • Total Use Of Primary Energy During The Life Cycle (Mj) Total Life Cycle : 1705.3991
    • Total Use Of Primary Energy During The Life Cycle (Mj) Manufacturing [A1-a3] : 166.7
    • Total Use Of Primary Energy During The Life Cycle (Mj) Distribution [A4] : 1.6179
    • Total Use Of Primary Energy During The Life Cycle (Mj) Installation [A5] : 1.4882
    • Total Use Of Primary Energy During The Life Cycle (Mj) Operational Energy Use [B6] : 1518.7
    • Total Use Of Primary Energy During The Life Cycle (Mj) End Of Life [C1-c4] : 16.893
    • Total Use Of Primary Energy During The Life Cycle (Mj) Benefits/Loads Beyond System Boundaries [D] : -51.495
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Manufacturing [A1-a3] : 5.1434
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 259.3
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Benefits/Loads Beyond System Boundaries [D] : -1.5298
    • Use Of Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 5.5715
    • Use Of Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 5.5715
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 1434.7025
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 155.99
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Distribution [A4] : 1.6179
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Installation [A5] : 1.3886
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 1259.4
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) End Of Life [C1-c4] : 16.306
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Benefits/Loads Beyond System Boundaries [D] : -49.965
    • Use Of Renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 1.4915
    • Use Of Renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 1.4915
    • Use Of Renewable Primary Energy Resources Used As Raw Materials (Mj) Benefits/Loads Beyond System Boundaries [D] : -1.4152
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 3.6518
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 259.3
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Benefits/Loads Beyond System Boundaries [D] : -0.1146
    • Water Use (M3 Eq) Manufacturing [A1-a3] : 3.4405
    • Water Use (M3 Eq) Operational Energy Use [B6] : 1.9155
    • Water Use (M3 Eq) End Of Life [C1-c4] : 70.441
    • Water Use (M3 Eq) Benefits/Loads Beyond System Boundaries [D] : -2.0638
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -25-55 °C - MID, -25-55 °C - MID, -25-70 °C - IEC, -25-70 °C - IEC, -25-60 °C - IEC, -25-60 °C - IEC-25-55 °C - MID, -25-55 °C - MID, -25-70 °C - IEC
    • Ambient Air Temperature For Storage : -40-85 °C, -40-85 °C
    • Ip Degree Of Protection : IP40 front panel: conforming to IEC 60529, IP20 body: conforming to IEC 60529
    • Operating Altitude : < 9842.52 ft (3000 m), < 9842.52 ft (3000 m)
    • Relative Humidity : 5-95 % 50-50 °C
    • Take Back : No
    • Halogene Performance : Halogen free plastic parts product
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 66.02527
    • 9 Mm Pitches : 14
    • Circularity Profile : ENVEOLI1404007_V2
    • Environmental Disclosure : ENVPEP1404007EN
    • Eu Rohs Directive : Compliant By Exemption
    • Halogen Content Performance : Halogen free plastic parts product
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1404007EN
    • Pep Verification Date : 2025-03-18
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : energy meter
  • ETIM
    • ETIM 8 : EC001506
    • ETIM 9 : EC001506
  • Output Attributes
    • Number Of Outputs : 1 digital (static)
    • Output Voltage : 5...40 V DC@50 mA
  • Input Attributes
    • Analogue Input Type : direct connection
    • Number Of Inputs : 1 digital 0...5 V/11...40 V 24 V DC
  • Specifications
    • Country of Origin : China, France, India, Mexico, Singapore
    • Depth : 69.3 mm