variable speed drive, Altivar 212, 1.5kW, 2hp, 480V, 3 phases, with EMC, IP21

ATV212 DRIVE 2HP 460V 2.5A

SQDATV212HU15N4 ATV212HU15N4 3606480322457
953.19 / EA
http://schema.org/OutOfStock
  • Dielectric Strength: 3535 V, 5092 V
  • IsSustainable: Yes
  • Warranty Length: 18 mth
This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP21 and it has a built-in EMC filter. It works at a rated power up to 1.5kW / 2hp and a rated voltage from 380V to 480V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 2kg and its dimensions are, 107mm wide, 143mm high, 150mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. It can also be mounted directly on a 35 mm wide DIN rail, thanks to the kit VW3A31852, to order separately. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet.
QTY
  • Product Description
  • Features
  • Specifications
This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP21 and it has a built-in EMC filter. It works at a rated power up to 1.5kW / 2hp and a rated voltage from 380V to 480V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 2kg and its dimensions are, 107mm wide, 143mm high, 150mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. It can also be mounted directly on a 35 mm wide DIN rail, thanks to the kit VW3A31852, to order separately. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Maximum Switching Current : 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R), 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R), 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R), 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R), 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R), 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R), 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R), 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R), 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R), 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R), 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R), 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R), 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R), 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R), 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R), 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R), 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R), 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R), 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R), 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R), 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R), 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R), 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R), 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R), 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R), 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R), 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R), 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R)
    • Maximum Transient Current : 4 A 60 s, 4 A 60 s
    • Minimum Switching Current : 3 mA 24 V DC configurable relay logic, 3 mA 24 V DC configurable relay logic, 3 mA 24 V DC configurable relay logic, 3 mA 24 V DC configurable relay logic
    • US Rated Supply Voltage : 380...480 V - 15...10 %, 380...480 V - 15...10 %
    • Maximum Horse Power Rating : 2 hp
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
    • Apparent Power : 2.8 kVA 380 V, 2.8 kVA 380 V
    • Asynchronous Motor Control Profile : voltage/frequency ratio - Energy Saving, quadratic U/f, voltage/frequency ratio, 5 points, voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo), voltage/frequency ratio, 2 points, flux vector control without sensor, standard
    • Dielectric Strength : 3535 V DC between earth and power terminals, 3535 V DC between earth and power terminals, 3535 V DC between earth and power terminals, 5092 V DC between control and power terminals, 5092 V DC between control and power terminals, 5092 V DC between control and power terminals
    • Discrete And Process Manufacturing : building - HVAC compressor for scroll, building - HVAC compressor for scroll, building - HVAC fan, building - HVAC fan, building - HVAC pump, building - HVAC pump
    • Electrical Connection : VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14, VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14, VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14, VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14, L1/R, L2/S, L3/T terminal 6-6 mm² / AWG 10, L1/R, L2/S, L3/T terminal 6-6 mm² / AWG 10, L1/R, L2/S, L3/T terminal 6-6 mm² / AWG 10, L1/R, L2/S, L3/T terminal 6-6 mm² / AWG 10
    • Electromagnetic Compatibility : electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2, electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2, electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2, radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3, radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3, radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3, electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4, electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4, electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4, 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5, 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5, 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5, conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6, conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6, conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6, voltage dips and interruptions immunity test conforming to IEC 61000-4-11, voltage dips and interruptions immunity test conforming to IEC 61000-4-11
    • Environmental Characteristic : classes 3C1 conforming to IEC 60721-3-3, classes 3C1 conforming to IEC 60721-3-3, classes 3S2 conforming to IEC 60721-3-3, classes 3S2 conforming to IEC 60721-3-3
    • Frequency Resolution : display unit 0.1 Hz, display unit 0.1 Hz, analog input 0.024/50 Hz, analog input 0.024/50 Hz
    • Insulation Resistance : >= 1 mOhm 500 V DC for 1 minute, >= 1 mOhm 500 V DC for 1 minute
    • Line Current : 2.5 A 480 V, 2.5 A 480 V, 3.2 A 380 V, 3.2 A 380 V
    • Linearity Error : VIA +/- 0.15 % of maximum value input, VIA +/- 0.15 % of maximum value input, VIA +/- 0.15 % of maximum value input, VIB +/- 0.15 % of maximum value input, VIB +/- 0.15 % of maximum value input, VIB +/- 0.15 % of maximum value input, FM +/- 0.2 % output, FM +/- 0.2 % output, FM +/- 0.2 % output
    • Local Signalling : 1 LED (red) for DC bus energized, 1 LED (red) for DC bus energized, 1 LED (red) for DC bus energized
    • Motor Slip Compensation : adjustable, not available in voltage/frequency ratio motor control, automatic whatever the load
    • Noise Level : 51 dB 86/188/EEC, 51 dB 86/188/EEC
    • Option Card : communication card LonWorks, communication card LonWorks
    • Power Range : 1.1-2 kW 380-440 V 3 phase, 1.1-2 kW 380-440 V 3 phase, 1.1-2 kW 380-440 V 3 phase, 1.1-2 kW 480-500 V 3 phase, 1.1-2 kW 480-500 V 3 phase, 1.1-2 kW 480-500 V 3 phase
    • Protection Type : overheating protection drive, overheating protection drive, thermal power stage drive, thermal power stage drive, short-circuit between motor phases drive, short-circuit between motor phases drive, input phase breaks drive, input phase breaks drive, overcurrent between output phases and earth drive, overcurrent between output phases and earth drive, overvoltages on the DC bus drive, overvoltages on the DC bus drive, break on the control circuit drive, break on the control circuit drive, against exceeding limit speed drive, against exceeding limit speed drive, line supply overvoltage and undervoltage drive, line supply overvoltage and undervoltage drive, line supply undervoltage drive, line supply undervoltage drive, against input phase loss drive, against input phase loss drive, thermal protection motor, thermal protection motor, motor phase break motor, motor phase break motor, with PTC probes motor, with PTC probes motor
    • Response Time : FM 2 ms +/- 0.5 ms analog, FM 2 ms +/- 0.5 ms analog, FM 2 ms +/- 0.5 ms analog, FM 2 ms +/- 0.5 ms analog, FLA, FLC 7 ms +/- 0.5 ms discrete, FLA, FLC 7 ms +/- 0.5 ms discrete, FLA, FLC 7 ms +/- 0.5 ms discrete, FLA, FLC 7 ms +/- 0.5 ms discrete, FLB, FLC 7 ms +/- 0.5 ms discrete, FLB, FLC 7 ms +/- 0.5 ms discrete, FLB, FLC 7 ms +/- 0.5 ms discrete, FLB, FLC 7 ms +/- 0.5 ms discrete, RY, RC 7 ms +/- 0.5 ms discrete, RY, RC 7 ms +/- 0.5 ms discrete, RY, RC 7 ms +/- 0.5 ms discrete, RY, RC 7 ms +/- 0.5 ms discrete
    • Sampling Duration : 2 ms +/- 0.5 ms F discrete, 2 ms +/- 0.5 ms F discrete, 2 ms +/- 0.5 ms F discrete, 2 ms +/- 0.5 ms F discrete, 2 ms +/- 0.5 ms R discrete, 2 ms +/- 0.5 ms R discrete, 2 ms +/- 0.5 ms R discrete, 2 ms +/- 0.5 ms R discrete, 2 ms +/- 0.5 ms RES discrete, 2 ms +/- 0.5 ms RES discrete, 2 ms +/- 0.5 ms RES discrete, 2 ms +/- 0.5 ms RES discrete, 3.5 ms +/- 0.5 ms VIA analog, 3.5 ms +/- 0.5 ms VIA analog, 3.5 ms +/- 0.5 ms VIA analog, 3.5 ms +/- 0.5 ms VIA analog, 22 ms +/- 0.5 ms VIB analog, 22 ms +/- 0.5 ms VIB analog, 22 ms +/- 0.5 ms VIB analog, 22 ms +/- 0.5 ms VIB analog
    • Shock Resistance : 15 gn 11 ms IEC 60068-2-27, 15 gn 11 ms IEC 60068-2-27, 15 gn 11 ms IEC 60068-2-27
    • Speed Accuracy : +/- 10 % of nominal slip 0.2 Tn to Tn, +/- 10 % of nominal slip 0.2 Tn to Tn
    • Supply : internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection, internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection, internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection, internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection, internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection, internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection, internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection, internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection, internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection, internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection, internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection, internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection
    • Supply Frequency : 50...60 Hz - 5...5 %, 50...60 Hz - 5...5 %
    • Switching Frequency : 6...16 kHz adjustable, 6...16 kHz adjustable, 12...16 kHz with derating factor, 12...16 kHz with derating factor
    • Tightening Torque : 1.3 N.m, 11.5 lb.in L1/R, L2/S, L3/T), 1.3 N.m, 11.5 lb.in L1/R, L2/S, L3/T), 1.3 N.m, 11.5 lb.in L1/R, L2/S, L3/T), 0.6 N.m VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES), 0.6 N.m VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
    • Transient Overtorque : 120-120 % of nominal motor torque +/- 10 % 60 s, 120-120 % of nominal motor torque +/- 10 % 60 s, 120-120 % of nominal motor torque +/- 10 % 60 s, 120-120 % of nominal motor torque +/- 10 % 60 s
    • Type Of Cable : without mounting kit 1 IEC cable 45 °C, copper 90 °C / XLPE/EPR, without mounting kit 1 IEC cable 45 °C, copper 90 °C / XLPE/EPR, without mounting kit 1 IEC cable 45 °C, copper 90 °C / XLPE/EPR, without mounting kit 1 IEC cable 45 °C, copper 90 °C / XLPE/EPR, without mounting kit 1 IEC cable 45 °C, copper 90 °C / XLPE/EPR, without mounting kit 1 IEC cable 45 °C, copper 90 °C / XLPE/EPR, without mounting kit 1 IEC cable 45 °C, copper 70 °C / PVC, without mounting kit 1 IEC cable 45 °C, copper 70 °C / PVC, without mounting kit 1 IEC cable 45 °C, copper 70 °C / PVC, without mounting kit 1 IEC cable 45 °C, copper 70 °C / PVC, without mounting kit 1 IEC cable 45 °C, copper 70 °C / PVC, without mounting kit 1 IEC cable 45 °C, copper 70 °C / PVC, with UL Type 1 kit 3 UL 508 cable 40 °C, copper 75 °C / PVC, with UL Type 1 kit 3 UL 508 cable 40 °C, copper 75 °C / PVC, with UL Type 1 kit 3 UL 508 cable 40 °C, copper 75 °C / PVC, with UL Type 1 kit 3 UL 508 cable 40 °C, copper 75 °C / PVC, with UL Type 1 kit 3 UL 508 cable 40 °C, copper 75 °C / PVC, with UL Type 1 kit 3 UL 508 cable 40 °C, copper 75 °C / PVC
    • Vibration Resistance : 1.5 mm (f= 3-13 Hz) conforming to IEC 60068-2-6, 1.5 mm (f= 3-13 Hz) conforming to IEC 60068-2-6, 1.5 mm (f= 3-13 Hz) conforming to IEC 60068-2-6, 1 gn (f= 13-200 Hz) conforming to EN/IEC 60068-2-8, 1 gn (f= 13-200 Hz) conforming to EN/IEC 60068-2-8, 1 gn (f= 13-200 Hz) conforming to EN/IEC 60068-2-8
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-12-06
    • HTML Description : Altivar 212 VFD2 HPContinuous Output Current: 3.7 ampsAC Line Input Line Voltage: 380/480 VAC Three Phase Input/OutputEnclosure Rating: IP20The Alitvar 212 drive includes: 3 logic inputs2 analog inputs1 analog output2 relay outputs (with 1 NO and 1 NO/NC contacts)Integrated 4 digit, 7-segment LED display with a 7 button keypadRJ45 Modbus port plus a four-screw terminal block for BACnet, Modbus, Metasys N2 and Apogee P1 communication protocolsLonWorks is available in an option card
    • Manufacturer : Schneider Electric
    • Device Type : Variable speed drive - VSD Compacts
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Average Life Duration : 10 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI110204EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : No
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS EUR Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : Yes
    • With Recycled Cardboard : No
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : YES_SSI2
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Function Option Id : ADVANCED
    • Function Option : Advanced
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • Assembly Style : with heat sink
    • Braking To Standstill : by DC injection
    • Device Short Name : ATV212
    • Functionality : mid
    • Isolation : electrical between power and control
    • Motor Power KW : 1.5 kW
    • Motor Starter Type : variable speed drive
    • Nominal Switching Frequency : 12 kHz
    • Package Weight Lbs : 1.977 kg
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : variable speed drive
    • Product Specific Application : pumps and fans in HVAC
    • Range Of Product : Altivar 212
    • Returnability : Yes
    • Specific Application : HVAC
    • Speed Range : 1-10
    • Sustainable Packaging : No
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP110204EN
    • Product Kit Identifier : N
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -10-40 °C (without derating), -10-40 °C (without derating), 40-50 °C (with derating factor), 40-50 °C (with derating factor)
    • EU ROHS Directive : Compliant By Exemption​, Pro-active compliance (Product out of EU RoHS legal scope)
    • IP Degree Of Protection : IP20 on upper part without blanking plate on cover IEC 61800-5-1, IP20 on upper part without blanking plate on cover IEC 61800-5-1, IP20 on upper part without blanking plate on cover IEC 61800-5-1, IP20 on upper part without blanking plate on cover IEC 61800-5-1, IP20 on upper part without blanking plate on cover IEC 60529, IP20 on upper part without blanking plate on cover IEC 60529, IP20 on upper part without blanking plate on cover IEC 60529, IP20 on upper part without blanking plate on cover IEC 60529, IP21 IEC 61800-5-1, IP21 IEC 61800-5-1, IP21 IEC 60529, IP21 IEC 60529, IP41 on upper part IEC 61800-5-1, IP41 on upper part IEC 61800-5-1, IP41 on upper part IEC 61800-5-1, IP41 on upper part IEC 60529, IP41 on upper part IEC 60529, IP41 on upper part IEC 60529
    • Operating Altitude : 3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m, 3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m, 3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m, <= 3280.84 ft (1000 m) without derating, <= 3280.84 ft (1000 m) without derating
    • Relative Humidity : 5-95 % without condensation IEC 60068-2-3, 5-95 % without condensation IEC 60068-2-3, 5-95 % without condensation IEC 60068-2-3, 5-95 % without dripping water IEC 60068-2-3, 5-95 % without dripping water IEC 60068-2-3, 5-95 % without dripping water IEC 60068-2-3
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Mercury Free : Yes
    • Circularity Profile : ENVEOLI110204EN
    • Environmental Disclosure : ENVPEP110204EN
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP110204EN
  • General Attributes
    • Product Or Component Type : variable speed drive
    • Range Of Product : Altivar 212
  • Output Attributes
    • Analogue Output Type : FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits, FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits, FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits, FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits, FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits, FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits, FM switch-configurable current 0...20 mA 970 Ohm 10 bits, FM switch-configurable current 0...20 mA 970 Ohm 10 bits, FM switch-configurable current 0...20 mA 970 Ohm 10 bits, FM switch-configurable current 0...20 mA 970 Ohm 10 bits, FM switch-configurable current 0...20 mA 970 Ohm 10 bits
    • Continuous Output Current : 3.7 A 380 V, 3.7 A 380 V, 3.7 A 460 V, 3.7 A 460 V
    • Discrete Output Type : configurable relay logic FLA, FLC) NO - 100000 cycles, configurable relay logic FLA, FLC) NO - 100000 cycles, configurable relay logic FLA, FLC) NO - 100000 cycles, configurable relay logic FLA, FLC) NO - 100000 cycles, configurable relay logic FLB, FLC) NC - 100000 cycles, configurable relay logic FLB, FLC) NC - 100000 cycles, configurable relay logic FLB, FLC) NC - 100000 cycles, configurable relay logic FLB, FLC) NC - 100000 cycles, configurable relay logic RY, RC) NO - 100000 cycles, configurable relay logic RY, RC) NO - 100000 cycles, configurable relay logic RY, RC) NO - 100000 cycles, configurable relay logic RY, RC) NO - 100000 cycles
    • Speed Drive Output Frequency : 0.5-200 Hz
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Input Attributes
    • Analogue Input Type : VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits, VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits, VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits, VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits, VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits, VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits, VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits, VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits, VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits, VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits, VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits, VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits, VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits, VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits, VIB configurable PTC probe 0...6 probes 1500 Ohm, VIB configurable PTC probe 0...6 probes 1500 Ohm, VIB configurable PTC probe 0...6 probes 1500 Ohm, VIB configurable PTC probe 0...6 probes 1500 Ohm, VIA switch-configurable current 0...20 mA 250 Ohm 10 bits, VIA switch-configurable current 0...20 mA 250 Ohm 10 bits, VIA switch-configurable current 0...20 mA 250 Ohm 10 bits, VIA switch-configurable current 0...20 mA 250 Ohm 10 bits, VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
    • Discrete Input Logic : positive logic (source) F, R, RES), <= 5 V, >= 11 V, positive logic (source) F, R, RES), <= 5 V, >= 11 V, positive logic (source) F, R, RES), <= 5 V, >= 11 V, positive logic (source) F, R, RES), <= 5 V, >= 11 V, negative logic (sink) F, R, RES), >= 16 V, <= 10 V, negative logic (sink) F, R, RES), >= 16 V, <= 10 V, negative logic (sink) F, R, RES), >= 16 V, <= 10 V, negative logic (sink) F, R, RES), >= 16 V, <= 10 V
    • Discrete Input Type : F programmable 24 V DC level 1 PLC 4700 Ohm, F programmable 24 V DC level 1 PLC 4700 Ohm, F programmable 24 V DC level 1 PLC 4700 Ohm, F programmable 24 V DC level 1 PLC 4700 Ohm, F programmable 24 V DC level 1 PLC 4700 Ohm, F programmable 24 V DC level 1 PLC 4700 Ohm, R programmable 24 V DC level 1 PLC 4700 Ohm, R programmable 24 V DC level 1 PLC 4700 Ohm, R programmable 24 V DC level 1 PLC 4700 Ohm, R programmable 24 V DC level 1 PLC 4700 Ohm, R programmable 24 V DC level 1 PLC 4700 Ohm, R programmable 24 V DC level 1 PLC 4700 Ohm, RES programmable 24 V DC level 1 PLC 4700 Ohm, RES programmable 24 V DC level 1 PLC 4700 Ohm, RES programmable 24 V DC level 1 PLC 4700 Ohm, RES programmable 24 V DC level 1 PLC 4700 Ohm, RES programmable 24 V DC level 1 PLC 4700 Ohm, RES programmable 24 V DC level 1 PLC 4700 Ohm