variable speed drive, Altivar Machine ATV340, 37kW, heavy duty, 400V, 3 phases, Ethernet

ATV340 ENET DR IP20 -50HP HD/

SQDATV340D37N4E ATV340D37N4E 3606480967108
8034.14 / EA
http://schema.org/OutOfStock
  • Connection Type: 1 X RJ45, Modbus Serial On Front Face, 1 X RJ45, Modbus Serial HMI On Front Face, 2 X RJ45, Ethernet IP/Modbus TCP On Front Face, 3 RJ45
  • Depth: 262.0 mm
  • IsSustainable: Yes
  • Operating Position: Vertical +/- 10 Degree
This Altivar 340 variable speed drive can feed 3-phase synchronous and asynchronous motors in open and closed loop control. Altivar Machine ATV340 drives are sized heavy duty as standard. It works at a rated power up to 37kW / 50hp and a rated voltage from 380V to 480V AC. ATV340 has been designed to meet the needs of applications for harsh environments, such as vibration, shock and non-conductive dust and where high temperature resistance up to 60 °C is needed. This product integrates Modbus serial line communication protocols as standard. This drive features multi-protocol Ethernet embedded, it consists of Ethernet IP and Modbus TCP communication interfaces. it weighs 28.4kg and its dimensions are, 213mm wide, 660mm high, 262mm deep. ATV340 incorporates functions and features suitable for the most common applications, including packaging, material handling, material working, hoisting. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions), IEC 60721-3, IEC 61508, IEC 13849-1. It is also CE, UL, CSA, and TÜV certified. Accessories and options (encoder interface modules, I/O expansion modules, communication modules, braking resistors, line chokes, additional EMC filters) are available with Altivar Machine ATV340 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. It is fully integrated inside Schneider Electric’s EcoStruxure Machine through DTM. It is possible to configure, control, and diagnose ATV340 drives directly in SoMachine and SoMove software by means of the same software brick (DTM).
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Assets
    • Cad : https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0000954_3D-CAD
  • Communications & Management Attributes
    • Communication Port Protocol : Modbus TCP, Modbus serial, EtherNet/IP
  • Conformance Attributes
    • Product Certifications : UL, CSA, TÜV, EAC, CTick
    • Standards : IEC 61800-3, IEC 61800-5-1, IEC 60721-3, IEC 61508, IEC 13849-1, UL 618000-5-1, UL 508C, IEC 61000-3-12
  • Complementary Attributes
    • Maximum Horse Power Rating : 60 hp normal duty, 50 hp heavy duty
    • Maximum Switching Current : relay output R1C inductive, cos phi = 0.4 7 ms 2 A 30 V DC, relay output R2C resistive, cos phi = 1 5 A 30 V DC, relay output R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC, relay output R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC, relay output R1C resistive, cos phi = 1 3 A 250 V AC, relay output R1C resistive, cos phi = 1 3 A 30 V DC, relay output R1C inductive, cos phi = 0.4 7 ms 2 A 250 V AC, relay output R2C resistive, cos phi = 1 5 A 250 V AC
    • Maximum Thdi : <48 % full load IEC 61000-3-12, <48 % full load IEC 61000-3-12, <48 % full load IEC 61000-3-12, <48 % 80 % load IEC 61000-3-12, <48 % 80 % load IEC 61000-3-12, <48 % 80 % load IEC 61000-3-12, <48 % full load IEC 61000-3-12, <48 % full load IEC 61000-3-12, <48 % full load IEC 61000-3-12, <48 % 80 % load IEC 61000-3-12
    • Maximum Transient Current : 111.8 A 2 s heavy duty), 105.6 A 60 s normal duty), 105.6 A 2 s normal duty), 111.8 A 60 s heavy duty)
    • Minimum Switching Current : relay output R1B 5 mA 24 V DC, relay output R2C 5 mA 24 V DC
    • Ue Rated Operational Voltage : 380...480 V 45 kW normal duty, 380...480 V 37 kW heavy duty, 380...480 V 60 hp normal duty, 380...480 V 50 hp heavy duty
    • Us Rated Supply Voltage : 380...480 V, 380...480 V - 15...10 %
    • Brake Chopper Integrated : true
    • Maximum Associated Fuse Rating : 125.0 A
    • Maximum Input Current Per Phase : 79.8 A
    • Maximum Output Frequency : 0.599 kHz
    • Maximum Output Voltage : 480 V
    • Maximum Acceleration Under Shock Impact During Operation : 150 m/s² at 11 ms
    • Maximum Acceleration Under Shock Load During Storage : 150 m/s² at 11 ms
    • Maximum Acceleration Under Shock Load During Transport : 150 m/s² at 11 ms
    • Maximum Acceleration Under Vibrational Stress During Operation : 10 m/s² at 13...200 Hz
    • Maximum Acceleration Under Vibratory Load During Storage : 10 m/s² at 13...200 Hz
    • Maximum Acceleration Under Vibratory Load During Transport : 10 m/s² at 13...200 Hz
    • Maximum Deflection Under Vibratory Load During Operation : 1.5 mm at 2...13 Hz
    • Maximum Deflection Under Vibratory Load During Storage : 1.5 mm at 2...13 Hz
    • Maximum Deflection Under Vibratory Load During Transport : 1.5 mm at 2...13 Hz
  • Important Information Attributes
    • Product Contributes To Saved And Avoided Emissions : YES_SSI2, Yes
    • Persona Type Ids : EU, OM, OM8, SI
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder, System Integrator
    • Apparent Power : 57.4 kVA 480 V normal duty), 49.1 kVA 480 V heavy duty)
    • Asynchronous Motor Control Profile : optimized torque mode, variable torque standard, constant torque standard
    • Connector Type : 1 x RJ45, Modbus serial on front face, 1 x RJ45, Modbus serial HMI on front face, 2 x RJ45, Ethernet IP/Modbus TCP on front face, 3 RJ45
    • Discrete And Process Manufacturing : packaging other application, hoisting tower crane, hoisting other application, material handling grouping conveyor, material handling palletizer - high performance, material working (wood, ceramic, stone, pvc, metal) cutting - high accuracy, material working (wood, ceramic, stone, pvc, metal) polishing, material working (wood, ceramic, stone, pvc, metal) grinding, material working (wood, ceramic, stone, pvc, metal) slitter, packaging filling bottles - synchronized operation, packaging feed conveyor - medium performance, packaging grouping boxing, packaging conveyor, packaging elevator, hoisting standard crane - hoist, material handling automatic storage / retrieval system, packaging shrinking wrapping
    • Electrical Connection : screw terminal 0.75...1.5 mm² control, screw terminal 35...50 mm² line side, screw terminal 35...50 mm² DC bus, screw terminal 50 mm² motor, control screw terminal 0.75...1.5 mm² AWG 18...AWG 16, line side screw terminal 35...50 mm² AWG 2...AWG 1, DC bus screw terminal 35...50 mm² AWG 3...AWG 1, motor screw terminal 50 mm² AWG 1
    • Electromagnetic Compatibility : electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2, radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3, electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4, 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5, conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
    • Encoder Protocol : 1 Vpp, EnDat 2.2, resolver, RS 422, SSI 24V, SSI 5V, TTL/HTL
    • Insulation Resistance : > 1 MOhm 500 V DC for 1 minute to earth, > 1 MOhm 500 V DC for 1 minute to earth, > 1 MOhm 500 V DC for 1 minute to earth, > 1 MOhm 500 V DC for 1 minute to earth
    • Line Current : 67.1 A, 59.0 A, 79.8 A 380 V normal duty), 69.1 A 480 V normal duty), 67.1 A 380 V heavy duty), 59.0 A 480 V heavy duty), 79.8 A 380 V with internal line choke normal duty), 69.1 A 480 V with internal line choke normal duty), 67.1 A 380 V with internal line choke heavy duty), 59 A 480 V with internal line choke heavy duty)
    • Linearity Error : AI1, AI2, AI3 +/- 0.15 % of maximum value analog input, AQ1, AQ2 +/- 0.2 % analog output
    • Method Of Access : slave Modbus RTU, slave Modbus TCP
    • Motor Power Kw : 45 kW normal duty, 37 kW heavy duty
    • Motor Slip Compensation : adjustable, can be suppressed, automatic whatever the load, not available in permanent magnet motor law
    • Option Card : communication module, PROFINET, communication module, DeviceNet, communication module, CANopen, communication module, EtherCAT
    • Power Dissipation In W : natural convection 90 W 380 V 4 kHz heavy duty), forced convection 796 W 380 V 4 kHz heavy duty), natural convection 105 W 380 V 4 kHz normal duty), forced convection 943 W 380 V 4 kHz normal duty)
    • Power Range : 30-50 kW 380-440 V 3 phase, 30-50 kW 480-500 V 3 phase
    • Protection Type : safe torque off drive, motor phase loss drive, thermal protection motor, safe torque off motor, motor phase loss motor, thermal protection drive, overheating drive, overcurrent drive, output overcurrent between motor phase and earth drive, output overcurrent between motor phases drive, short-circuit between motor phase and earth drive, short-circuit between motor phases drive, DC Bus overvoltage drive, line supply overvoltage drive, line supply undervoltage drive, input supply loss drive, exceeding limit speed drive, break on the control circuit drive
    • Sampling Duration : 2 ms +/- 0.5 ms DI1...DI8) - discrete input, 5 ms +/- 1 ms DI7, DI8) - pulse input, 1 ms +/- 1 ms AI1, AI2, AI3) - analog input, 5 ms +/- 1 ms AQ1, AQ2) - analog output
    • Switching Frequency : 2...16 kHz adjustable, 4...16 kHz with derating factor
    • Synchronous Motor Control Profile : reluctance motor, permanent magnet motor
    • Transmission Rate : 4.8 kbit/s, 9.6 kbit/s, 19.2 kbit/s, 38.4 kbit/s
    • Vibration Resistance : 1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6, 1 gn 13-200 Hz)IEC 60068-2-6
    • Environmental Class During Storage : class 1C3 according to EN 60721-3-1, class 1S2 according to EN 60721-3-1
    • Environmental Class During Transport : class 2C3 according to EN 60721-3-2, class 2S1 according to EN 60721-3-2
    • Carbon Footprint Of The Distribution Phase A4 : 4.6467243699, 5 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 8.0073678904, 8 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 5 kg CO2 eq., 4.8750496027
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 321 kg CO2 eq., 320.671639726
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 26 963 kg CO2 eq., 26962.6720466774
    • Motor Power Hp 12 : 60 hp normal duty, 50 hp heavy duty
    • Motor Power Kw 10 : 45 kW normal duty, 37 kW heavy duty
    • Medium Desc : variable speed drive, Altivar Machine ATV340, 37kW, heavy duty, 400V, 3 phases, Ethernet
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-01-12
    • Global Commercial Status : Commercialised
    • Return Indicator : Y
    • Country Of Origin 6 : US
    • Stocking Flag : N
    • Device Type : Variable speed drive - VSD Compacts
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Average Life Duration : 10 year(s)
    • Legacy Weee Scope : In
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2510022EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • Product Kit Identifier : N
    • 1 Phase Low Current Possible : false
    • 4 Quadrant Operation Possible : true
    • Application In Domestic And Commercial Area Permitted : false
    • Assembly Style : with heat sink
    • Base Load Current At High Overload : 74.5 A
    • Base Load Current At Low Overload : 88.0 A
    • Braking To Standstill : by DC injection
    • Capacity Of Dc Link : 3000.0 µF
    • Computer Port : true
    • Data Format : 8 bits, configurable odd, even or no parity
    • Design Of Frequency Changer : U converter
    • Emc Filter : class C3 EMC filter integrated
    • Exchange Mode : half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
    • Housing Material : plastic
    • Isolation : between power and control terminals
    • Marking : CE
    • Maximum Associated Fuse Rating : 125.0 A
    • Maximum Input Current Per Phase : 79.8 A
    • Motor Starter Type : variable speed drive
    • Mounting Mode : wall mount
    • Network Frequency : 50-60 Hz
    • Noise Level : 63.5 dB
    • Nominal Switching Frequency : 4 kHz
    • Number Of Addresses : 1-247
    • Operating Element Present : true
    • Operating Position : vertical +/- 10 degree
    • Optical Interface Present : false
    • Overvoltage Category : class III
    • Phase : 3 phase
    • Power Loss Per Device Current Dependent : 903.0 W
    • Power Loss Static Current Independent : 33.0 W
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : variable speed drive
    • Product Specific Application : machine
    • Prospective Line Isc : 50 kA
    • Range Of Product : Altivar Machine ATV340
    • Refresh Time : relay output R1, R2, R3)5 ms +/- 0.5 ms)
    • Regulation Loop : adjustable PID regulator
    • Relative Symmetric Mains Voltage Tolerance : 10 %
    • Relative Symmetric Network Frequency Tolerance : 5 %
    • Returnability : Yes
    • Safety Function : STO (safe torque off) SIL 3
    • Shock Resistance : 15 gn 11 ms IEC 60068-2-27
    • Software Version : EIME v5.9.1
    • Specific Application : machine
    • Supply Frequency : 50...60 Hz +/- 5 %
    • Supporting Protocol For As Interface Safety At Work : false
    • Supporting Protocol For Asi : false
    • Supporting Protocol For Bacnet : false
    • Supporting Protocol For Can : false
    • Supporting Protocol For Data Highway : false
    • Supporting Protocol For Devicenet : false
    • Supporting Protocol For Devicenet Safety : false
    • Supporting Protocol For Ethernet Ip : true
    • Supporting Protocol For Foundation Fieldbus : false
    • Supporting Protocol For Interbus : false
    • Supporting Protocol For Knx : false
    • Supporting Protocol For Lon : false
    • Supporting Protocol For Modbus : true
    • Supporting Protocol For Other Bus Systems : false
    • Supporting Protocol For Profibus : false
    • Supporting Protocol For Profinet Cba : false
    • Supporting Protocol For Profinet Io : false
    • Supporting Protocol For Profisafe : false
    • Supporting Protocol For Safetybus P : false
    • Supporting Protocol For Sercos : false
    • Supporting Protocol For Suconet : false
    • Supporting Protocol For Tcp Ip : true
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 27 301 kg CO2 eq.
    • Transmission Frame : RTU
    • Type Of Cooling : forced convection
    • Type Of Polarization : no impedance
    • Volume Of Cooling Air : 240.0 m3/h
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • With Safety Function Safe Programmable Logic : false
    • Application In Industrial Area Permitted : true
    • Supporting Protocol For Interbus Safety : false
    • Emc Limit Value Complied : true
    • Permitted Relative Humidity During Transport : class 2K5 according to EN 60721-3
    • With Safety Function Safe Brake Management Sbc Sbt : true
    • With Safety Function Safe Direction Sdi : false
    • With Safety Function Safe Operating Stop Sos : false
    • With Safety Function Safe Position Sp : false
    • With Safety Function Safe Speed Monitor Ssm : false
    • With Safety Function Safe Stop 1 Ss1 : true
    • With Safety Function Safe Torque Off Sto : true
    • With Safety Function Safely Limited Position Slp : false
    • With Safety Function Safely Limited Speed Sls : true
    • With Sft Fct Safe Stop 2 Ss : false
    • Pep Code : ENVPEP2510022EN
    • Database Version : 2016-11
    • Pep Verification Date : 2021-11-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional Unit Description : To adapt the speed and torque of synchronous, asynchronous or reluctance motor to the machine s operating point for 45 kW electric motors for fluid management and industrial applications in IP21/UL type 1 conditions, at 380V to 480V rated 3-phase voltage supply. Calculation of the environmental impacts is based on 10 years of product service lifetime. The usage profile taken into account is 80% uptime in use phase at 75% loading rate and 20% uptime in stand by phase.
    • Functional Unit Unit : unité (unit)
    • Energy Model Manufacturing A1 A3 2 : Energy model used: China
    • Energy Model Installation A5 2 : Electricity Mix; AC; < 1kV; EU-27
    • Energy Model Use B6 2 : Electricity Mix; AC; < 1kV; EU-27
    • Energy Model End Of Life C1 C4 2 : Electricity Mix; AC; < 1kV; EU-27
    • Height Nominal : 660.0 mm
    • Width Nominal : 213.0 mm
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -15-50 °C without derating vertical position), -15-50 °C without derating vertical position), -15-50 °C without derating vertical position), -15-60 °C, -15-50 °C without derating vertical position), -15-50 °C without derating vertical position), -15-50 °C without derating vertical position), 50-60 °C with derating factor vertical position)
    • Ambient Air Transport Temperature : -40-70 °C, -40-70 °C
    • Operating Altitude : <= 4800 m with current derating above 1000m, <= 4800 m with current derating above 1000m, <= 4800 m with current derating above 1000m, <= 4800 m with current derating above 1000m
    • Environmental Class During Operation : class 3C3 according to IEC 60721-3-3, class 3S3 according to IEC 60721-3-3
    • Take Back : Nej
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 27300.8728282665
    • Ambient Air Temperature For Storage : -40-70 °C
    • Circularity Profile : ENVEOLI2510022EN
    • Environmental Disclosure : ENVPEP2510022EN
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP20
    • Nema Degree Of Protection : NEMA 1
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Permitted Relative Humidity During Operation : class 3K5 according to EN 60721-3
    • Permitted Relative Humidity During Storage : class 1K5 according to EN 60721-3
    • Pep Code : ENVPEP2510022EN
    • Pep Verification Date : 2021-11-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Phase : 3 phase
    • Product Or Component Type : variable speed drive
    • Range Of Product : Altivar Machine ATV340
  • ETIM
    • ETIM 8 : EC001857
    • ETIM 9 : EC001857
  • Output Attributes
    • Analogue Output Type : software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits, software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
    • Continuous Output Current : 88 A 4 kHz normal duty, 74.5 A 4 kHz heavy duty
    • Relay Output Type : relay outputs R1A, relay outputs R1C 100000 cycles, relay outputs R2A, relay outputs R2C 100000 cycles
    • Analogue Output Number : 2
    • Discrete Output Number : 1.0
    • Discrete Output Type : programmable output DQ1, DQ2 30 V DC 100 mA
    • Maximum Output Frequency : 0.599 kHz
    • Maximum Output Voltage : 480 V
    • Nominal Output Current : 74.5 A
    • Nominal Output Power : 37.0 kW
    • Output Voltage : <= power supply voltage
    • Relay Output Number : 3
    • Speed Drive Output Frequency : 0.1-599 Hz
  • Surge Protection And Filtering Attributes
    • Emc Filter : class C3 EMC filter integrated
  • Input Attributes
    • Analogue Input Type : AI1 software-configurable current 0...20 mA 250 Ohm 12 bits, AI1 software-configurable temperature probe or water level sensor, AI1 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits, AI2 software-configurable voltage - 10...10 V DC 31.5 kOhm 12 bits
    • Discrete Input Logic : positive logic (source) STOA, STOB), < 5 V, > 11 V, positive logic (source) DI1...DI8), < 5 V, > 11 V, negative logic (sink) DI1...DI8), > 16 V, < 10 V, positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V, 16 preset speeds
    • Discrete Input Type : PTI safe torque off 0-30 kHz, 24 V DC 30 V), DI1...DI5 programmable as pulse input, 24 V DC 30 V)3.5 kOhm, programmable
    • Input Compatibility : STOA, STOB discrete input level 1 PLC IEC 61131-2, DI1...DI8 discrete input level 1 PLC IEC 61131-2, DI7, DI8 pulse input level 1 PLC IEC 65A-68
    • Input Output Type : logic output DQ- 0-1 kHz, <= 30 V DC, 100 mA, logic output DQ+ 0-1 kHz, <= 30 V DC, 100 mA, programmable as pulse output DQ+ 0-30 kHz, <= 30 V DC, 20 mA
    • Analogue Input Number : 3
    • Discrete Input Number : 8
    • Number Of Input Phases : 3
  • Specifications
    • Country of Origin : Indonesia, Sweden
    • Depth : 262.0 mm