TeSys Deca Manual Starter and Protector, magnetic circuit protector, rotary handle, 25 A, EverLink BTR connectors

TeSys Manual Switch 600VAC 25A

SQDGV3L25 GV3L25 3389119405423
369.16 / EA
http://schema.org/OutOfStock
  • Country of Origin: France
  • Depth: 136 mm
  • Height: 132 mm
  • Net Weight: 0.96 kg
  • Warranty Length: 18 mth
  • Weight: 0.96 kg
  • Width: 55 mm
TeSys GV motor circuit breaker, 3 poles (3P), 25A/690V, for 3-phase motor applications 11kW@400V. It provides a magnetic protection with a tripping level at 14xIn, high breaking capacity Icu 100kA@400V. Connection by Everlink BTR screw terminals. Start-stop control by rotary handle guaranteed for 50 000 cycles AC-3. To complete motor protection, use it in association with a thermal overload relay LRD325 (to be ordered separately). Multi standards certified (IEC, CCC, EAC, Marine).
QTY
  • Product Description
  • Features
  • Specifications
TeSys GV motor circuit breaker, 3 poles (3P), 25A/690V, for 3-phase motor applications 11kW@400V. It provides a magnetic protection with a tripping level at 14xIn, high breaking capacity Icu 100kA@400V. Connection by Everlink BTR screw terminals. Start-stop control by rotary handle guaranteed for 50 000 cycles AC-3. To complete motor protection, use it in association with a thermal overload relay LRD325 (to be ordered separately). Multi standards certified (IEC, CCC, EAC, Marine).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Product Certifications : CCC || UL || CSA || EAC || LROS (Lloyds register of shipping) || BV || ABS || DNV-GL || UKCA
    • Mechanical Robustness : shocks 15 Gn for 11 ms contactor open || shocks 30 Gn for 11 ms contactor closed || vibrations 4 Gn, 5...300 Hz
    • Ambient Air Temperature For Operation : -20-60 °C
    • Standards : EN/IEC 60947-2 || EN/IEC 60947-4-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC/EN 60335-1:Clause 30.2 || IEC/EN 60335-2-40:Annex JJ
    • Climatic Withstand : IACS E10
    • Ambient Air Temperature For Storage : -40-80 °C
    • Ip Degree Of Protection : IP20 IEC 60529
    • Operating Altitude : 9842.52 ft (3000 m)
    • Fire Resistance : 960 °C IEC 60695-2-11
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP060901
    • Packaging Without Single Use Plastic : No
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Scip Number : 2057c252-f956-4ac1-a3d9-75119bc8a000
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Circularity Profile : ENVEOLI060901
    • Take-Back : No
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 21.070000000000004
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 5.484113459283891
    • Carbon Footprint Of The Distribution Phase [A4] : 0.3 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase [A5] : 0.1 kg CO2 eq.
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 30 kg CO2 eq.
    • Eu Rohs Directive : Compliant with Exemptions
    • Carbon Footprint Of The End-Of-Life Phase [C1 To C4] : 2.5759934932242534
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 29.52248774600692
  • Complementary
    • Line Rated Current : 25 A
    • [Ue] Rated Operational Voltage : 690 V AC 50/60 Hz IEC 60947-2
    • Height : 132 mm
    • Network Type : AC
    • Magnetic Tripping Current : 350-350 A
    • [Ith] Conventional Free Air Thermal Current : 25 A IEC 60947-2
    • Motor Power Kw : 11-11 kW 400/415 V AC 50/60 Hz || 15-15 kW 500 V AC 50/60 Hz || 18.5-18.5 kW 690 V AC 50/60 Hz
    • Utilisation Category : category A IEC 60947-2 || AC-3 IEC 60947-4-1
    • Net Weight : 0.96 kg
    • Fixing Mode : 35 mm symmetrical DIN rail clipped || panel screwed with 3 x M4 screws)
    • [Uimp] Rated Impulse Withstand Voltage : 6 kV IEC 60947-2
    • [Ics] Rated Service Short-Circuit Breaking Capacity : 100 % 230/240 V AC 50/60 Hz || 100 % 400/415 V AC 50/60 Hz || 100 % 440 V AC 50/60 Hz || 50 % 500 V AC 50/60 Hz || 50 % 690 V AC 50/60 Hz
    • Control Type : rotary handle
    • Power Dissipation Per Pole : 8 W
    • Electrical Durability : 50000 cycles AC-3 415 V In
    • [Ui] Rated Insulation Voltage : 690 V AC 50/60 Hz IEC 60947-2
    • Breaking Capacity : 100 kA Icu 230/240 V AC 50/60 Hz || 100 kA Icu 400/415 V AC 50/60 Hz || 50 kA Icu 440 V AC 50/60 Hz || 12 kA Icu 500 V AC 50/60 Hz || 6 kA Icu 690 V AC 50/60 Hz
    • Suitability For Isolation : yes IEC 60947-1
    • Tightening Torque : 5 N.m screw clamp terminal
    • Mechanical Durability : 50000 cycles
    • Poles Description : 3P
    • Mounting Position : horizontal || vertical
    • Color : dark grey
    • Width : 55 mm
    • Depth : 136 mm
    • Network Frequency : 50/60 Hz IEC 60947-2
  • Specifications
    • Country of Origin : France
    • Width : 55 mm
    • Height : 132 mm
    • Weight : 0.96 kg
    • Product Or Component Type : motor circuit breaker
    • Product Name : TeSys GV3
    • Range : TeSys Deca
    • Device Application : motor protection
    • Device Short Name : GV3L
    • Trip Unit Technology : magnetic