TeSys GV2 Manual Starter and Protector, thermal magnetic circuit protector, toggle switch, 0.63…1 A, screw clamp terminals

MANUAL STARTER 600VAC 1AMP IEC

SQDGV2RT05 GV2RT05 3389110520613
187.29 / EA
http://schema.org/OutOfStock
  • Country of Origin: France
  • Depth: 78.5 mm
  • Height: 89 mm
  • Warranty Length: 18 mth
  • Width: 45 mm
TeSys GV motor circuit breaker, 3 poles (3P), 1A/690V, for high starting current peak motor applications 0.25-0.37kW@400V. It provides a thermal-magnetic protection with a thermal setting range 0.63-1A, a magnetic tripping level at 20xIn, high breaking capacity Icu 100kA. Connection by screw clamp terminals. Start-stop control by toggle guaranteed for 100 000 cycles AC-3. It can be used for protection of 3-phase transformer applications. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).
QTY
  • Product Description
  • Features
  • Specifications
TeSys GV motor circuit breaker, 3 poles (3P), 1A/690V, for high starting current peak motor applications 0.25-0.37kW@400V. It provides a thermal-magnetic protection with a thermal setting range 0.63-1A, a magnetic tripping level at 20xIn, high breaking capacity Icu 100kA. Connection by screw clamp terminals. Start-stop control by toggle guaranteed for 100 000 cycles AC-3. It can be used for protection of 3-phase transformer applications. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Product Certifications : CCC || UL || CSA || EAC || LROS (Lloyds register of shipping) || BV || UKCA
    • Operating Altitude : <= 6561.68 ft (2000 m)
    • Ik Degree Of Protection : IK04
    • Mechanical Robustness : shocks 30 Gn for 11 ms || vibrations 5 Gn, 5...150 Hz
    • Ambient Air Temperature For Operation : -20-60 °C
    • Standards : EN/IEC 60947-2 || EN/IEC 60947-4-1
    • Climatic Withstand : IACS E10
    • Ambient Air Temperature For Storage : -40-80 °C
    • Ip Degree Of Protection : IP20 IEC 60529
    • Fire Resistance : 960 °C IEC 60695-2-11
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Take-Back : No
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 1.215349398124056
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 42 kg CO2 eq.
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 42.230195991788385
    • Packaging Made With Recycled Cardboard : Yes
    • Environmental Disclosure : ENVPEP121004
    • Packaging Without Single Use Plastic : Yes
    • Scip Number : 04104e70-ba29-493c-b2cc-b5837d1f879b
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Carbon Footprint Of The Installation Phase [A5] : 0.024988562296268852
    • Circularity Profile : ENVEOLI121004
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 40.392
    • Carbon Footprint Of The End-Of-Life Phase [C1 To C4] : 0.5 kg CO2 eq.
    • Carbon Footprint Of The Distribution Phase [A4] : 0.1 kg CO2 eq.
    • Eu Rohs Directive : Compliant with Exemptions
  • Complementary
    • Line Rated Current : 1 A
    • [Ue] Rated Operational Voltage : 690 V AC 50/60 Hz IEC 60947-2
    • Rated Duty : uninterrupted IEC 60947-4-1
    • Network Type : AC
    • [Ith] Conventional Free Air Thermal Current : 1 A IEC 60947-2
    • Motor Power Kw : 0.09-0.09 kW 220/230 V AC 50/60 Hz motor protection high peak current || 0.12-0.12 kW 220/230 V AC 50/60 Hz motor protection high peak current || 0.25-0.25 kW 400/415 V AC 50/60 Hz motor protection high peak current || 0.37-0.37 kW 400/415 V AC 50/60 Hz motor protection high peak current || 0.25-0.25 kW 440 V AC 50/60 Hz motor protection high peak current || 0.37-0.37 kW 440 V AC 50/60 Hz motor protection high peak current || 0.37-0.37 kW 500 V AC 50/60 Hz motor protection high peak current || 0.55-0.55 kW 690 V AC 50/60 Hz motor protection high peak current || 0.63-0.63 kW 440 V AC 50/60 Hz transformer protection || 0.63-0.63 kW 500 V AC 50/60 Hz transformer protection || 1-1 kW 690 V AC 50/60 Hz transformer protection
    • Utilisation Category : category A IEC 60947-2 || AC-3 IEC 60947-4-1 || AC-3e IEC 60947-4-1
    • [Uimp] Rated Impulse Withstand Voltage : 6 kV IEC 60947-2
    • [Ui] Rated Insulation Voltage : 690 V AC 50/60 Hz IEC 60947-2
    • Thermal Protection Adjustment Range : 0.63-1 A IEC 60947-2
    • Poles Description : 3P
    • Mounting Position : horizontal || vertical
    • Width : 45 mm
    • Depth : 78.5 mm
    • Network Frequency : 50/60 Hz IEC 60947-2
    • Height : 89 mm
    • Magnetic Tripping Current : 22-22 A
    • Connections - Terminals : power circuit screw clamp terminal 2 1-6 mm²solid || power circuit screw clamp terminal 2 1.5-6 mm²flexible without cable end || power circuit screw clamp terminal 2 1-4 mm²flexible with cable end
    • Fixing Mode : 35 mm symmetrical DIN rail clipped || panel screwed with adaptor plate)
    • Control Type : toggle
    • Power Dissipation Per Pole : 2.5 W
    • Electrical Durability : 100000 cycles AC-3 415 V In || 100000 cycles AC-3e 415 V In
    • Breaking Capacity : 100 kA Icu 220/230 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 690 V AC 50/60 Hz IEC 60947-2
    • Suitability For Isolation : yes IEC 60947-1
    • Tightening Torque : 1.7 N.m screw clamp terminal
    • Mechanical Durability : 100000 cycles
  • Specifications
    • Country of Origin : France
    • Width : 45 mm
    • Height : 89 mm
    • Product Or Component Type : motor circuit breaker
    • Product Name : TeSys GV2
    • Trip Unit Technology : thermal-magnetic
    • Range : TeSys Deca
    • Device Application : motor protection || transformer
    • Device Short Name : GV2RT