TeSys Deca Manual Starter and Protector, thermal magnetic circuit protector, push buttons, 0.16...0.25 A, spring terminals

MANUAL STARTER 600VAC 0.40AMP

SQDGV2ME023 GV2ME023 3389110346350
167.10 / EA
http://schema.org/OutOfStock
  • Country of Origin: France
  • Depth: 78.5 mm
  • Height: 101 mm
  • Net Weight: 0.28 kg
  • Warranty Length: 18 mth
  • Weight: 0.28 kg
  • Width: 45 mm
TeSys GV motor circuit breaker, 3 poles (3P), 0.25A/690V, for 3-phase motor applications 0.06kW@400V. It provides a thermal-magnetic protection with a thermal setting range 0.16-0.25A, magnetic tripping at 9xIn, high breaking capacity Icu 100kA@400V. Connection by spring terminals. Start-stop control by push-button guaranteed for 100 000 cycles AC-3. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX).
QTY
  • Product Description
  • Features
  • Specifications
TeSys GV motor circuit breaker, 3 poles (3P), 0.25A/690V, for 3-phase motor applications 0.06kW@400V. It provides a thermal-magnetic protection with a thermal setting range 0.16-0.25A, magnetic tripping at 9xIn, high breaking capacity Icu 100kA@400V. Connection by spring terminals. Start-stop control by push-button guaranteed for 100 000 cycles AC-3. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Product Certifications : CCC || UL || CSA || EAC || ATEX || LROS (Lloyds register of shipping) || BV || RINA || DNV-GL || UKCA
    • Ik Degree Of Protection : IK04
    • Mechanical Robustness : shocks 30 Gn for 11 ms || vibrations 5 Gn, 5...150 Hz
    • Ambient Air Temperature For Operation : -20-60 °C
    • Standards : EN/IEC 60947-2 || EN/IEC 60947-4-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC/EN 60335-2-40:Annex JJ || IEC/EN 60335-1:Clause 30.2
    • Climatic Withstand : IACS E10
    • Ambient Air Temperature For Storage : -40-80 °C
    • Ip Degree Of Protection : IP20 IEC 60529
    • Operating Altitude : <= 6561.68 ft (2000 m)
    • Fire Resistance : 960 °C IEC 60695-2-11
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Packaging Made With Recycled Cardboard : Yes
    • Environmental Disclosure : ENVPEP121004
    • Packaging Without Single Use Plastic : Yes
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Scip Number : 04104e70-ba29-493c-b2cc-b5837d1f879b
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Circularity Profile : ENVEOLI121004
    • Take-Back : No
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 40.392
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 1.4935293714724507
    • Carbon Footprint Of The Distribution Phase [A4] : 0.1 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase [A5] : 0 kg CO2 eq.
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 43 kg CO2 eq.
    • Eu Rohs Directive : Compliant with Exemptions
    • Carbon Footprint Of The End-Of-Life Phase [C1 To C4] : 0.6531889958637732
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 42.650938629908836
  • Complementary
    • Line Rated Current : 0.25 A
    • [Ue] Rated Operational Voltage : 690 V AC 50/60 Hz IEC 60947-2
    • Height : 101 mm
    • Phase Failure Sensitivity : yes IEC 60947-4-1
    • Rated Duty : uninterrupted IEC 60947-4-1
    • Network Type : AC
    • Magnetic Tripping Current : 3.08-3.08 A
    • [Ith] Conventional Free Air Thermal Current : 0.25 A IEC 60947-2
    • Motor Power Kw : 0.06-0.06 kW 400/415 V AC 50/60 Hz
    • Utilisation Category : category A IEC 60947-2 || AC-3 IEC 60947-4-1 || AC-3e IEC 60947-4-1
    • Net Weight : 0.28 kg
    • Connections - Terminals : power circuit spring terminals 2 1-6 mm²solid || power circuit spring terminals 2 1.5-4 mm²flexible without cable end || power circuit spring terminals 2 1-4 mm²flexible with cable end
    • Fixing Mode : 35 mm symmetrical DIN rail clipped || panel screwed with adaptor plate)
    • [Uimp] Rated Impulse Withstand Voltage : 6 kV IEC 60947-2
    • [Ics] Rated Service Short-Circuit Breaking Capacity : 100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 100 % 400/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 100 % 690 V AC 50/60 Hz IEC 60947-2
    • Control Type : push-button
    • Power Dissipation Per Pole : 2.5 W
    • Electrical Durability : 100000 cycles AC-3 415 V In || 100000 cycles AC-3e 415 V In
    • [Ui] Rated Insulation Voltage : 690 V AC 50/60 Hz IEC 60947-2
    • Breaking Capacity : 100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 690 V AC 50/60 Hz IEC 60947-2
    • Suitability For Isolation : yes IEC 60947-1
    • Thermal Protection Adjustment Range : 0.16-0.25 A IEC 60947-2
    • Mechanical Durability : 100000 cycles
    • Poles Description : 3P
    • Mounting Position : horizontal || vertical
    • Color : dark grey
    • Width : 45 mm
    • Depth : 78.5 mm
    • Network Frequency : 50/60 Hz IEC 60947-2
  • Specifications
    • Country of Origin : France
    • Width : 45 mm
    • Height : 101 mm
    • Weight : 0.28 kg
    • Product Or Component Type : motor circuit breaker
    • Product Name : TeSys GV2
    • Range : TeSys Deca
    • Device Application : motor protection
    • Device Short Name : GV2ME
    • Trip Unit Technology : thermal-magnetic