Motor circuit breaker, TeSys Deca, 3P, 3.5A, Icu 50kA, thermal magnetic, multifunction, UL489

Motor circuit breaker, TeSys G

SQDGV4PB03N GV4PB03N 3606489868567
638.08 / EA
http://schema.org/OutOfStock
  • Country of Origin: Poland
  • Depth: 116 mm
  • Height: 171 mm
  • Net Weight: 1.45 kg
  • Operating Position: Any Position
  • Warranty Length: 18 mth
  • Weight: 1.45 kg
  • Width: 81 mm
TeSys GV motor circuit breaker, 3 poles (3P), 3.5A/690V, for protection of 3-phase motors 0.55-1.5kW@400V. Multifunction circuit breaker UL489 compliant, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 1.4-3.5A, a selectable tripping class 10 or 20, rated tripping current 125%, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL 489, CSA C22.2 N°5).
QTY
  • Product Description
  • Specifications
TeSys GV motor circuit breaker, 3 poles (3P), 3.5A/690V, for protection of 3-phase motors 0.55-1.5kW@400V. Multifunction circuit breaker UL489 compliant, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 1.4-3.5A, a selectable tripping class 10 or 20, rated tripping current 125%, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL 489, CSA C22.2 N°5).
  • Environment
    • Product Certifications : IEC || UL || CSA
    • Standards : EN/IEC 60947-1 || EN/IEC 60947-2 || EN/IEC 60947-4-1 || UL 489 || CSA C22.2 No 5
    • Operating Altitude : 5000 m
    • Ik Degree Of Protection : IK07 IEC 62262
    • Ambient Air Temperature For Operation : -25-70 °C
    • Climatic Withstand : IACS E10
    • Pollution Degree : 3
    • Ambient Air Temperature For Storage : -50-85 °C
    • Ip Degree Of Protection : IP40 IEC 60529
    • Fire Resistance : 960 °C IEC 60695-2-11
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Mercury Free : Yes
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Take-Back : No
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 10.821233215111057
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 90 kg CO2 eq.
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 89.69612279863219
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Environmental Disclosure : ENVPEP1704004EN
    • Halogen Content Performance : Halogen free plastic parts product
    • Packaging Without Single Use Plastic : Yes
    • Scip Number : 1b259a2c-3a3c-401a-acdd-f0837efd4018
    • Carbon Footprint Of The Installation Phase [A5] : 0.4077956243417599
    • Circularity Profile : ENVEOLI1704004EN
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 74.322
    • Carbon Footprint Of The End-Of-Life Phase [C1 To C4] : 4 kg CO2 eq.
    • Carbon Footprint Of The Distribution Phase [A4] : 0.5 kg CO2 eq.
    • Pvc Free : Yes
    • Eu Rohs Directive : Not compliant
  • Complementary
    • Line Rated Current : 3.5 A
    • [Ue] Rated Operational Voltage : 690 V AC 50/60 Hz IEC 60947-2 || 600Y/347 V AC 60 Hz UL 489
    • Rated Duty : continuous IEC 60947-4-1
    • [Ith] Conventional Free Air Thermal Current : 115 A IEC 60947-4-1
    • Operating Position : any position
    • Connections - Terminals : EverLink BTR screw connectors top) 1 1.5-70 mm² - rigid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - rigid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
    • Utilisation Category : category A IEC 60947-2 || AC-3 IEC 60947-4-1
    • Net Weight : 1.45 kg
    • [Uimp] Rated Impulse Withstand Voltage : 8 kV IEC 60947-2
    • [Ui] Rated Insulation Voltage : 800 V AC 50/60 Hz IEC 60947-2
    • Poles Description : 3P
    • Width : 81 mm
    • Depth : 116 mm
    • Mechanical Robustness : vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
    • Height : 171 mm
    • Phase Failure Sensitivity : yes IEC 60947-4-1
    • Magnetic Tripping Current : 60-60 A
    • Maximum Operating Rate : 25 cyc/h
    • [Ics] Rated Service Short-Circuit Breaking Capacity : 100 % 220/240 V AC 50/60 Hz IEC 60947-2 || 100 % 380/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 100 % 525 V AC 50/60 Hz IEC 60947-2 || 25 % 660/690 V AC 50/60 Hz IEC 60947-2
    • Control Type : toggle
    • Power Dissipation Per Pole : 4.6 W
    • Electrical Durability : 40000 cycles AC-3 440 V In/2 || 40000 cycles AC-3 440 V In
    • Breaking Capacity : 65 kA SCCR 240 V AC 60 Hz UL 489 || 35 kA SCCR 480Y/277 V AC 60 Hz UL 489 || 18 kA SCCR 600Y/347 V AC 60 Hz UL 489 || 100 kA Icu 220/240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 380/415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 25 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 8 kA Icu 660/690 V AC 50/60 Hz IEC 60947-2
    • Suitability For Isolation : yes IEC 60947-1
    • Tightening Torque : 9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
    • Mechanical Durability : 40000 cycles
    • Color : Gray RAL 7016)
  • Specifications
    • Country of Origin : Poland
    • Width : 81 mm
    • Height : 171 mm
    • Weight : 1.45 kg
    • Product Or Component Type : motor circuit breaker
    • Product Name : TeSys GV4 || TeSys Deca
    • Trip Unit Technology : thermal-magnetic || electronic
    • Range Of Product : TeSys GV4
    • Range : TeSys Deca
    • Device Application : motor protection
    • Device Short Name : GV4PB