Auxiliary contact, TeSys GV4, 690VAC, 1 NO/NC

Auxiliary contact, TeSys GV4, 690VAC, 1 NO/NC

SQDGV4AE11 GV4AE11 3606485444246
46.15 / EA
http://schema.org/OutOfStock
  • Contact Configuration: 1 NO/NC
  • Mounting Type: Internal Mounting
  • Rated Power: 110 V, -12 120 W, -12 66 W, -12 75 W, 24 V, 250 V, 48 V
  • Strip Length: 8 mm
TeSys GV4 auxiliary contact block, for motor circuit breakers GV4. 1C/O contact, it performs Open/Close OF function or Trip alarm SD function, depending of its location in the circuit breaker. Rated for operation up to 5A/690V AC and 5A/250V DC. To be plugged inside the circuit breaker, in the right-hand cavity for OF function, in the left-hand cavity for SD function, connection by spring terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
QTY
  • Product Description
  • Specifications
TeSys GV4 auxiliary contact block, for motor circuit breakers GV4. 1C/O contact, it performs Open/Close OF function or Trip alarm SD function, depending of its location in the circuit breaker. Rated for operation up to 5A/690V AC and 5A/250V DC. To be plugged inside the circuit breaker, in the right-hand cavity for OF function, in the left-hand cavity for SD function, connection by spring terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP1704004EN
    • Sustainable Offer Status : Green Premium product
    • Toxic Heavy Metal Free : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Reach Free Of Svhc : Yes
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • China Rohs Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Circularity Profile : ENVEOLI1704004EN
    • Eu Rohs Directive : Compliant
  • Specifications
    • Auxiliary Contact Composition : 1 NO/NC
    • [Ue] Rated Operational Voltage : <= 690 V
    • Range Compatibility : TeSys TeSys GV4 || TeSys TeSys BV4
    • [Ith] Conventional Free Air Thermal Current : 5 A IEC 60947-5-1 || 5 A CSA C22.2 No 14 || 5 A UL 508
    • Product Or Component Type : auxiliary contact
    • Range : TeSys
    • Mounting Mode : internal mounting
    • Device Application : signalling
    • Device Short Name : GV4AE
  • Complementary
    • Rated Power In W : DC-12 120 W 24 V IEC 60947-5-1 || DC-12 120 W 48 V IEC 60947-5-1 || DC-12 66 W 110 V IEC 60947-5-1 || DC-12 75 W 250 V IEC 60947-5-1
    • Minimum Switching Current : 2 mA
    • Rated Power In Va : 120 VA AC-12 24 V IEC 60947-5-1 || 240 VA AC-12 48 V IEC 60947-5-1 || 635 VA AC-12 110/127 V IEC 60947-5-1 || 1200 VA AC-12 230/240 V IEC 60947-5-1 || 2200 VA AC-12 380/440 V IEC 60947-5-1 || 3450 VA AC-12 660/690 V IEC 60947-5-1
    • Associated Fuse Rating : 5 A gG at 690 V conforming to IEC 60947-5-1
    • Connections - Terminals : spring terminals 1 0.5-1.5 mm² - cable stiffness: flexible without cable end
    • Wire Stripping Length : 8 mm
    • [Ui] Rated Insulation Voltage : 690 V IEC 60947-1
    • [Ie] Rated Operational Current : 5 A <= 690 V AC-12 IEC 60947-5-1 || 0.3 A 250 V DC-12 IEC 60947-5-1 || 2.5 A <= 24 V DC-12 IEC 60947-5-1 || 1.2 A 48 V DC-12 IEC 60947-5-1 || 0.35 A 110/127 V DC-12 IEC 60947-5-1 || 0.05 A 250 V DC-12 IEC 60947-5-1 || 1 A <= 24 V DC-12 IEC 60947-5-1 || 0.2 A 48 V DC-12 IEC 60947-5-1 || 0.05 A 110/127 V DC-12 IEC 60947-5-1 || 0.03 A 250 V DC-12 IEC 60947-5-1 || 5 A <= 48 V AC-15 IEC 60947-5-1 || 4 A 110/127 V AC-15 IEC 60947-5-1 || 3 A 220/240 V AC-15 IEC 60947-5-1 || 2.5 A 380...440 V AC-15 IEC 60947-5-1 || 0.11 A 660/690 V AC-15 IEC 60947-5-1 || 5 A <= 24 V DC-12 IEC 60947-5-1 || 2.5 A 48 V DC-12 IEC 60947-5-1 || 0.6 A 110/127 V DC-12 IEC 60947-5-1
    • Minimum Switching Voltage : 17 V
    • Mechanical Durability : 40000 cycles
  • Environment
    • Quantity Per Set : set of 1