Pump Panel, NEMA Type S, Well Guard, oil field, Size 4, 135A, 100HP, 200A fusible disconnect, Motor Logic SSOLR, 440/480VAC 50/60Hz coil, NEMA 3R

PUMP AANEL 480VAC 135AMP NEMA

SQD8940WF3S2V06A28H30 8940WF3S2V06A28H30 785901466918
9248.82 / EA
http://schema.org/OutOfStock
  • Certifications: NEMA, UL Listed
  • Depth: 262 mm
  • Fuse Type: H Or K
  • Height: 1435 mm
  • Line Rated Current: 135 A
  • Mounting Type: Surface
  • NEMA: 4
  • Number of Poles: 3
  • Warranty Length: 18 mth
  • Width: 622 mm
Well-Guard pumping plant panels are designed for pumping applications. This panel is specifically designed for oil field applications. These panels provide extra space for field installation of auxiliary equipment. These panels us Type S non-reversing magnetic starters. Panel has a 200A fusible disconnect switch. Fuse clips are sized for use with dual-element time-delay fuses This panel has a 3 pole NEMA Size 4 starter that has a 135 ampere rating. This NEMA Size 4 starter has a maximum of 100 HP rating three phase. This non-reversing NEMA motor starter has a Motor Logic overload relay with a 45A to 135A range to sense over current conditions. The starters in these panels are available with a wide variety of replaceable coil voltages. The starter in this device has a 440/480 VAC 50/60 Hz operating coil wired for common control. A painted sheet steel NEMA 3R rainproof enclosure is used to protect this starter. Enclosure is 56.50 inches tall, 23.00 inches wide and 10.33 inches deep. A wide variety of accessories are available for Type S starters. This pump panel is supplied with a START momentary push button and a HAND/OFF/AUTO selector switch. These NEMA pump panels with Type S starters are UL listed and marked Suitable for use as Service Equipment. They are also CSA certified.
QTY
  • Product Description
  • Specifications
Well-Guard pumping plant panels are designed for pumping applications. This panel is specifically designed for oil field applications. These panels provide extra space for field installation of auxiliary equipment. These panels us Type S non-reversing magnetic starters. Panel has a 200A fusible disconnect switch. Fuse clips are sized for use with dual-element time-delay fuses This panel has a 3 pole NEMA Size 4 starter that has a 135 ampere rating. This NEMA Size 4 starter has a maximum of 100 HP rating three phase. This non-reversing NEMA motor starter has a Motor Logic overload relay with a 45A to 135A range to sense over current conditions. The starters in these panels are available with a wide variety of replaceable coil voltages. The starter in this device has a 440/480 VAC 50/60 Hz operating coil wired for common control. A painted sheet steel NEMA 3R rainproof enclosure is used to protect this starter. Enclosure is 56.50 inches tall, 23.00 inches wide and 10.33 inches deep. A wide variety of accessories are available for Type S starters. This pump panel is supplied with a START momentary push button and a HAND/OFF/AUTO selector switch. These NEMA pump panels with Type S starters are UL listed and marked Suitable for use as Service Equipment. They are also CSA certified.
  • Environment
    • Product Certifications : UL Listed || NEMA
    • Nema Degree Of Protection : NEMA 3R
    • Enclosure Type : weatherproof enclosure indoor/outdoor
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Eu Rohs Directive : Under investigation
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary
    • Thermal Overload Type : Motor Logic solid state class 10/20
    • Disconnector Device Type : fusible disconnect switch
    • Height : 1435 mm
    • Control Type : selector switch HAND-OFF-AUTO) || push-button START)
    • Nema Size : 4
    • Device Mounting : surface
    • Fuse Type : H or K
    • Maximum Horse Power Rating : 100-100 hp 480 V AC, 3 phase
    • [Uc] Control Circuit Voltage : 480 V AC 60 Hz || 440 V AC 50 Hz
    • Electrical Connection : screw terminal
    • Line Rated Current : 135 A
    • Protection Type : overload || phase loss || phase unbalance
    • Control Circuit : common control circuit
    • Width : 622 mm
    • Depth : 262 mm
    • Permissible Voltage : 600 V AC
    • Associated Fuse Rating : 400 A
    • Number Of Poles : 3
  • Specifications
    • Product Name : Well-Guard Control
    • Device Application : pumping