Pump Panel, NEMA Type S, Well Guard, oil field, Size 1, 27A, 10 HP, HLL36030M71 circuit breaker, melting alloy overload, 120 VAC 60 Hz coil, NEMA 3R

PUMP PANEL 480VAC 27AMP NEMA +

SQD8940XC4S2V02SY61 8940XC4S2V02SY61 785901057123
2399.30 / EA
http://schema.org/OutOfStock
  • Number of Poles: 3
  • Warranty Length: 18 mth
Well-Guard pumping plant panels are designed for pumping applications. This panel is specifically designed for oil field applications. These panels provide extra space for field installation of auxiliary equipment. These panels us Type S non-reversing magnetic starters. Panel has a HLL36030M71 circuit breaker. This panel has a 3 pole NEMA Size 1 starter that has a 27 ampere rating. This NEMA Size 1 starter has a maximum of 10 HP rating three phase. This non-reversing NEMA motor starter has a melting alloy type overload relay that uses Type B thermal units to sense over current conditions. The starters in these panels are available with a wide variety of replaceable coil voltages. The starter in this device has a 110/120 VAC 50/60 Hz operating coil wired for separate control. A painted sheet steel NEMA 3R rainproof slim line enclosure is used to protect this starter. Enclosure is 38.50 inches tall, 19.00 inches wide and 9.39 inches deep. A wide variety of accessories are available for Type S starters. This pump panel is supplied with a HAND/OFF/AUTO selector switch. These NEMA pump panels with Type S starters are UL listed and marked Suitable for use as Service Equipment. They are also CSA certified.
QTY
  • Product Description
  • Features
  • Specifications
Well-Guard pumping plant panels are designed for pumping applications. This panel is specifically designed for oil field applications. These panels provide extra space for field installation of auxiliary equipment. These panels us Type S non-reversing magnetic starters. Panel has a HLL36030M71 circuit breaker. This panel has a 3 pole NEMA Size 1 starter that has a 27 ampere rating. This NEMA Size 1 starter has a maximum of 10 HP rating three phase. This non-reversing NEMA motor starter has a melting alloy type overload relay that uses Type B thermal units to sense over current conditions. The starters in these panels are available with a wide variety of replaceable coil voltages. The starter in this device has a 110/120 VAC 50/60 Hz operating coil wired for separate control. A painted sheet steel NEMA 3R rainproof slim line enclosure is used to protect this starter. Enclosure is 38.50 inches tall, 19.00 inches wide and 9.39 inches deep. A wide variety of accessories are available for Type S starters. This pump panel is supplied with a HAND/OFF/AUTO selector switch. These NEMA pump panels with Type S starters are UL listed and marked Suitable for use as Service Equipment. They are also CSA certified.
  • Control Type
    • selector switch HAND-OFF-AUTO)
  • Permissible Voltage
    • 600 V AC
  • Enclosure Type
    • weatherproof enclosure indoor/outdoor
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • UC Control Circuit Voltage
    • 120 V AC 60 Hz
    • 110 V AC 50 Hz
  • Accessories
    • 9999TC10
    • 9999TC20
  • Maximum Horse Power Rating
    • 10-10 hp 480 V AC, 3 phase
  • Important Information Attributes
    • B2B Bullet Point 1 : Designed for irrigation or oil field applications
    • B2B Bullet Point 2 : Approved for submersible pump applications
    • B2B Bullet Point 3 : Ambient temperature compensated
    • B2B Bullet Point 4 : Includes a Start push button and a Hand-Off-Auto selector switch
    • B2B Bullet Point 5 : Adjustable trip current
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-13
    • Legacy WEEE Scope : In
    • WEEE Product Category : 5
    • Scope Perimeter : Outside of Europe
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Will not be Compliant
    • ROHS EUR Full Compliance Status : Not compliant
    • ROHS EUR Full Compliance Status Id : NOT_COMPLIANT
    • China ROHS In Scope : No
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • WD Status : 5 - INITIALIZED WITH DataSCAN OK (Migration)
    • Circuit Breaker Ct Rating : 30 A
    • Device Short Name : S2
    • Number Of Poles : 3
    • Package Weight Lbs : 40.37 kg
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Range : Square D
    • Returnability : No
    • Sustainable Packaging : No
    • Thermal Overload Type : melting alloy
    • Relationship Type : Compatible relationship
    • Nbr Of Units In Pkg : 1
    • Warranty In Months : 18
  • Environment Attributes
    • China ROHS url : https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=exportPdfRoHSChina&pid=402913063&lang=en-us
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • EU ROHS Directive : Not compliant
    • Nema Size : 1
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months