Contactor, Tesys N Contactors, nonreversing, 3P, 3phase, 18A, 5HP at 460VAC, NEMA size 0, 120VAC 50/60Hz coil, open

NEMA SZ 0 CONTACTOR 3P 120VAC

SQDT02BN13G7 T02BN13G7 3606480573101
289.65 / EA
http://schema.org/OutOfStock
  • Certifications: CSA, UL Listed
  • Contact Configuration: 1 NO + 1 NC
  • Depth: 3.66 in
  • Height: 3.34 in
  • Line Rated Current: 18 A
  • Net Weight: 0.91 lb
  • Number of Phases: 3
  • Width: 1.76 in
TeSys N contactors and starters conform to NEMA ICS2 standards. The NEMA size is printed directly on the face of the contactor. The 3 pole NEMA size 0 contactor has an 18 amperage continuous current rating. It also has ratings of 3 HP at 200 to 230 Vac and 5 HP at 460 and 575 VAC poly phase. The contactor has a 120 VAC replaceable coil with common control. Contactor has 1 normally open and 1 normally closed auxiliary contact. This contactor is not in an enclosure. Contactor is UL listed and CSA Certified. This contactor is 3.34 inches tall, 1.76 inches wide and 3.66 inches deep. It weighs 0.91 lbs. The screw clamp terminals will accept power wires from 18 AWG to 8 AWG and control wires from 18 AWG to 10 AWG. This TeSys N contactor is UL listed and CSA Certified.
QTY
  • Product Description
  • Specifications
TeSys N contactors and starters conform to NEMA ICS2 standards. The NEMA size is printed directly on the face of the contactor. The 3 pole NEMA size 0 contactor has an 18 amperage continuous current rating. It also has ratings of 3 HP at 200 to 230 Vac and 5 HP at 460 and 575 VAC poly phase. The contactor has a 120 VAC replaceable coil with common control. Contactor has 1 normally open and 1 normally closed auxiliary contact. This contactor is not in an enclosure. Contactor is UL listed and CSA Certified. This contactor is 3.34 inches tall, 1.76 inches wide and 3.66 inches deep. It weighs 0.91 lbs. The screw clamp terminals will accept power wires from 18 AWG to 8 AWG and control wires from 18 AWG to 10 AWG. This TeSys N contactor is UL listed and CSA Certified.
  • Complementary
    • [Uc] Control Circuit Voltage : 120 V AC
    • Height : 3.34 in
    • Auxiliary Contact Composition : 1 NO + 1 NC
    • Electrical Connection : screw clamp terminals
    • Phase : 3 phase
    • Net Weight : 0.91 lb(US)
    • Poles Description : 3P
    • Line Rated Current : 18 A
    • Control Circuit : common control circuit
    • Width : 1.76 in
    • Depth : 3.66 in
    • [Ue] Rated Operational Voltage : 600 V AC
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Pvc Free : Yes
    • Toxic Heavy Metal Free : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Reach Free Of Svhc : Yes
    • China Rohs Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Eu Rohs Directive : Compliant
  • Specifications
    • Range Of Product : TeSys N
    • Nema Size : 0
    • Contactor Application : non-reversing
    • Product Or Component Type : contactor
    • Maximum Horse Power Rating : 3 hp 200 V AC || 3 hp 230 V AC || 5 hp 460 V AC || 5 hp 575 V AC
  • Environmental
    • Product Certifications : UL Listed || CSA
    • Nema Degree Of Protection : not rated (open device)