TeSys F - contactor coil - LX1FK - 415...440V AC 40...400 Hz

CONTACTOR COIL 480VAC IEC

SQDLX1FK415 LX1FK415 3389110082289
484.35 / EA
http://schema.org/OutOfStock
  • Net Weight: 1.15 kg
  • Warranty Length: 18 mth
TeSys F AC coil 415/440V 40-400Hz (voltage code N7/R7), low sealed consumption, for TeSys F 3-pole and 4-pole contactors LC1F500. It operates in voltage limits 0.85-1.1 Uc and environments until 55°C. It provides high operating rates to the contactor, until 2400 cycles/hour. Green Premium compliant (RoHS/REACh).
QTY
  • Product Description
  • Specifications
TeSys F AC coil 415/440V 40-400Hz (voltage code N7/R7), low sealed consumption, for TeSys F 3-pole and 4-pole contactors LC1F500. It operates in voltage limits 0.85-1.1 Uc and environments until 55°C. It provides high operating rates to the contactor, until 2400 cycles/hour. Green Premium compliant (RoHS/REACh).
  • Environment
    • Ambient Air Temperature For Operation : -5-55 °C
    • Net Weight : 1.15 kg
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP1505009EN
    • Sustainable Offer Status : Green Premium product
    • Toxic Heavy Metal Free : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Reach Free Of Svhc : Yes
    • China Rohs Regulation : X
    • Circularity Profile : ENVEOLI1505009EN
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
  • Complementary
    • Control Circuit Voltage Limits : operational 0.85...1.1 Uc 40...400 Hz 55 °C) || drop-out 0.3...0.5 Uc 40...400 Hz 55 °C)
    • Inrush Power In Va : 1100-1100 VA 40...400 Hz cos phi 0.9 (at 20 °C)
    • Coil Technology : without built-in suppressor module
    • Hold-In Power Consumption In Va : 18-18 VA 40...400 Hz cos phi 0.3 (at 20 °C)
    • Heat Dissipation : 18-18 W 40...400 Hz
  • Specifications
    • Average Resistance : 143 Ohm inrush 20 °C || 3730 Ohm holding 20 °C
    • [Uc] Control Circuit Voltage : 415 V AC 40...400 Hz
    • Control Circuit Type : AC 40...400 Hz
    • Range Compatibility : TeSys TeSys F LC1F contactor
    • Product Or Component Type : contactor coil
    • Range : TeSys
    • Inductance Of Closed Circuit : 18.4 H
    • Maximum Operating Rate : 2400 cyc/h 55 °C
    • Operating Time : 100...170 ms opening || 40...75 ms closing
    • Product Compatibility : LC1F500
    • Device Short Name : LX1FK
    • Mechanical Durability : 10 Mcycles