TeSys D, replaement coil, for LC1D09 to 38 contactors and CAD relays, 120 VAC 50/60 Hz coil

IEC CONTACT REPLACE COIL 120V

SQDLXD1G7 LXD1G7 3389110467758
36.99 / EA
http://schema.org/OutOfStock
  • Net Weight: 0.07 kg
  • Warranty Length: 18 mth
TeSys D replacement coils are for replacing the operating coil in a TeSys D contactors with 9 amperes to 38 ampere ratings and Tesys D Relays. This coil has an operating voltage of 120 Vac 50/60 Hz. This coil has an inrush consumption rating of 70 VA and a sealed consumpation rating ofd 7 VA. The 60Hz operating range is 85 to 110% of nomial voltage at 60 degrees C.
QTY
  • Product Description
  • Specifications
TeSys D replacement coils are for replacing the operating coil in a TeSys D contactors with 9 amperes to 38 ampere ratings and Tesys D Relays. This coil has an operating voltage of 120 Vac 50/60 Hz. This coil has an inrush consumption rating of 70 VA and a sealed consumpation rating ofd 7 VA. The 60Hz operating range is 85 to 110% of nomial voltage at 60 degrees C.
  • Environment
    • Ambient Air Temperature For Operation : -5-60 °C
    • Net Weight : 0.07 kg
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Pvc Free : Yes
    • Toxic Heavy Metal Free : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Reach Free Of Svhc : Yes
    • China Rohs Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
  • Complementary
    • Control Circuit Voltage Limits : drop-out: 0.3...0.6 Uc at 50/60 Hz (at <60 °C) || operational: 0.8...1.1 Uc at 50 Hz (at <60 °C) || operational: 0.85...1.1 Uc at 60 Hz (at <60 °C)
    • Inrush Power In Va : 70-70 VA 60 Hz cos phi 0.75 (at 20 °C) || 70-70 VA 50 Hz cos phi 0.75 (at 20 °C)
    • Coil Technology : without built-in suppressor module
    • Hold-In Power Consumption In Va : 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C) || 7-7 VA 50 Hz cos phi 0.3 (at 20 °C)
    • Heat Dissipation : 2-3 W 50/60 Hz
  • Specifications
    • Average Resistance : 150.6 Ohm 20 °C
    • [Uc] Control Circuit Voltage : 120 V AC 50/60 Hz
    • Control Circuit Type : AC 50/60 Hz
    • Product Or Component Type : contactor coil
    • Range : TeSys
    • Inductance Of Closed Circuit : 5.4 H
    • Maximum Operating Rate : 3600 cyc/h 60 °C
    • Mechanical Durability : 15 Mcycles
    • Product Compatibility : LC1D09...D38 || CAD || LC1DT20...DT40
    • Device Short Name : LXD1