Auxiliary contact block, TeSys K, 4NC, front mounting, screw clamp terminals

CONTACTOR+RELAY AUX CONTACT 57

SQDLA1KN04 LA1KN04 3389110500158
21.98 / EA
http://schema.org/OutOfStock
  • Depth: 35 mm
  • Warranty Length: 18 mth
TeSys K instantaneous auxiliary contact block, for contactors LC.K, LP.K, CA.K with screw clamp terminals (except LP4K, LP5K, CA4K). It provides 4NC contacts rated up to 10A 690V AC, connection by screw clamp terminals. Front mounting by clip-on, it procures high reliability and durability. Multi standards certified (IEC, UL, CSA, CCC).
QTY
  • Product Description
  • Specifications
TeSys K instantaneous auxiliary contact block, for contactors LC.K, LP.K, CA.K with screw clamp terminals (except LP4K, LP5K, CA4K). It provides 4NC contacts rated up to 10A 690V AC, connection by screw clamp terminals. Front mounting by clip-on, it procures high reliability and durability. Multi standards certified (IEC, UL, CSA, CCC).
  • Complementary Attributes
    • Ui Rated Insulation Voltage : 690 V IEC 60947-5-1, 600 V UL 60947-5-1, 600 V CSA C22.2 No 60947-5-1
    • Irms Rated Making Capacity : 110 A at <= 690 V AC conforming to IEC 60947
    • Minimum Switching Current : 5 mA
    • Minimum Switching Voltage : 17 V
    • Ue Rated Operational Voltage : 690 V AC 25...400 Hz
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Environmental Characteristic : normal environment
    • Mounting Location : front
    • Permissible Short Time Rating : 80 A 1 s, 60 A 500 ms, 110 A 100 ms
    • Product Or Component Type : auxiliary contact block
    • Protective Treatment : TC IEC 60068
    • Range : TeSys
    • Range Of Product : TeSys K, TeSys K control relay
    • Tightening Torque : 1.3 N.m Philips No 2, 1.3 N.m pozidriv No 2
    • Connections Terminals : screw clamp terminals 2 0.75-4 mm²flexible without cable end, screw clamp terminals 2 1.5-4 mm²rigidscrew clamp terminals 1 0.34-1.5 mm²flexible with cable end, screw clamp terminals 1 0.75-4 mm²flexible without cable end, screw clamp terminals 1 1.5-4 mm²rigid, screw clamp terminals 2 0.34-1.5 mm²flexible with cable end
    • Carbon Footprint Of The Distribution Phase A4 : 0.0058845, 0 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.1 kg CO2 eq., 0.11352
    • Carbon Footprint Of The Installation Phase A5 : 0.0043312, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 0.9 kg CO2 eq., 0.92084
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 3 kg CO2 eq., 3.1606
    • Certificate Agency : CB Scheme, CCC, UL, CSA, CE, UKCA
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-03-25
    • Return Indicator : Y
    • Stocking Flag : N
    • Stock Policy : 2
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Use Carbon Footprint : 3.1606
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Conformity Date : 1926
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : No
    • China Rohs Label : 1
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Associated Fuse Rating : 10 A gG at <= 690 V conforming to IEC 60947
    • Compatibility Code : LA1
    • Device Short Name : LA1
    • Insulation Resistance : > 10 MOhm> 10 MOhm
    • Non Overlap Distance : 0.5 mm
    • Pole Contact Composition : 4 NC
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Name : TeSys K
    • Returnability : Yes
    • Shielding Continuity Terminal : without
    • Software Version : v5.9.4
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 4 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Ith Conventional Free Air Thermal Current : 10 A (at 50 °C)
    • Warranty In Months : 18
    • Pole Contact Comp : 4 NC
    • Connections Terminals 55 Connections Terminals : screw clamp terminals
    • Pep Code : ENVPEP2106022EN
    • Database Version : 2022-01
    • Pep Verification Date : 2025-06-17
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional-unit Description : To add instantaneous auxiliary contact blocks in front face on TeSys k contactors as NO and/or NC contacts for 20 years.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime, In Y : 20
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model - Installation [A5] : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model - Use [B6] : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model - End Of Life [C1-c4] : Electricity Mix; Production mix; Low voltage; FR
    • Recyclability Potential, In % : 43
    • Offer Owner Code : 190788
    • Pn : 1
    • Height Nominal : 30 mm
    • Width Nominal : 38 mm
    • Climate Change - Fossil Fuels ( Kg Co2 Eq.) Operational Energy Use [B6] : 3.1524
    • Climate Change - Total ( Kg Co2 Eq.) Operational Energy Use [B6] : 3.1606
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Manufacturing [A1-a3] : 15.02
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Operational Energy Use [B6] : 606.91
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) End Of Life [C1-c4] : 3.4464
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Benefits/Loads Beyond System Boundaries [D] : -1.6105
    • Ecotoxicity (Fresh Water) (Ctue) Manufacturing [A1-a3] : 269.98
    • Ecotoxicity (Fresh Water) (Ctue) Operational Energy Use [B6] : 22.321
    • Ecotoxicity (Fresh Water) (Ctue) Benefits/Loads Beyond System Boundaries [D] : -1.993
    • Hazardous Waste Disposed Of (Kg) Manufacturing [A1-a3] : 20.864
    • Hazardous Waste Disposed Of (Kg) Benefits/Loads Beyond System Boundaries [D] : -1.1598
    • Ionizing Radiation, Human Health (Kbq Of U235 Equiv.) Operational Energy Use [B6] : 81.925
    • Materials For Recycling (Kg) Installation [A5] : 0.006
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Benefits/Loads Beyond System Boundaries [D] : -0.1974
    • Total Use Of Primary Energy During The Life Cycle (Mj) Manufacturing [A1-a3] : 16.438
    • Total Use Of Primary Energy During The Life Cycle (Mj) Operational Energy Use [B6] : 663.02
    • Total Use Of Primary Energy During The Life Cycle (Mj) End Of Life [C1-c4] : 3.4467
    • Total Use Of Primary Energy During The Life Cycle (Mj) Benefits/Loads Beyond System Boundaries [D] : -1.6359
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Manufacturing [A1-a3] : 1.4177
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 56.111
    • Use Of Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Benefits/Loads Beyond System Boundaries [D] : -0.1974
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 14.076
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 606.91
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) End Of Life [C1-c4] : 3.4464
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Benefits/Loads Beyond System Boundaries [D] : -1.4131
    • Use Of Renewable Primary Energy Resources Used As Raw Materials (Mj) Benefits/Loads Beyond System Boundaries [D] : -0.0324
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 1.3647
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 56.111
    • Water Use (M3 Eq) Benefits/Loads Beyond System Boundaries [D] : -0.0434
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Ambient Air Temperature For Operation : -25-50 °C, -25-50 °C
    • Ambient Air Temperature For Storage : -50-80 °C, -50-80 °C
    • Take Back : No
    • Reach Free Shvc : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 4.205175700000001
    • Environmental Disclosure : ENVPEP2106022EN
    • Eu Rohs Directive : Compliant
    • Ip Degree Of Protection : IP20 conforming to IEC 60529
    • Operating Altitude : 6561.68 ft (2000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2106022EN
    • Pep Verification Date : 2025-06-17
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : auxiliary contact block
    • Range Of Product : TeSys K, TeSys K control relay
  • ETIM
    • ETIM 8 : EC000041
    • ETIM 9 : EC000041
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Brazil, France, United Kingdom, Indonesia, Singapore, United States
    • Depth : 35 mm