TeSys Deca thermal overload relays - 9...13 A - class 20

9-13A class 20 OLR w/ Everlink

SQDLRD313L LRD313L 3389119215527
135.30 / EA
http://schema.org/OutOfStock
  • Dielectric Strength: 1.89 kV, 50 Hz
  • Warranty Length: 18 mth
LRD313L is a TeSys LRD thermal overload relay from Schneider Electric to be used with a TeSys D contactor. It protects motors 5.5kW@400V thanks to a thermal range 9-13A, a tripping class 20 and phase unbalance protection. LRD313L is a TeSys LRD thermal overload relay from Schneider Electric for direct mounting on TeSys D contactors. With a thermal setting range 9-13A, a tripping class 20 and phase unbalance detection, it protects motors 5.5kW@400V. It provides manual test & reset buttons, automatic reset, trip auxiliary contact and flag indicator. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine). Thermal overload protection relay, bimetallic type, with phase unbalance protection (differential). Direct mounting on the bottom terminals of a Tesys contactor LC1D40A-D65A to form a compact starter. Light and compact, 55mm wide. Temperature compensated for a good accuracy of the protection. Manual control with test & reset buttons, manual / automatic reset selector. Trip signaling with 1NO+1NC auxiliary contacts and trip flag indicator. Can be completed with terminal blocks for separate mounting (LAD7B, LAD96) and remote control devices (LAD703, LA7D03).
QTY
  • Product Description
  • Features
  • Specifications
LRD313L is a TeSys LRD thermal overload relay from Schneider Electric to be used with a TeSys D contactor. It protects motors 5.5kW@400V thanks to a thermal range 9-13A, a tripping class 20 and phase unbalance protection. LRD313L is a TeSys LRD thermal overload relay from Schneider Electric for direct mounting on TeSys D contactors. With a thermal setting range 9-13A, a tripping class 20 and phase unbalance detection, it protects motors 5.5kW@400V. It provides manual test & reset buttons, automatic reset, trip auxiliary contact and flag indicator. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine). Thermal overload protection relay, bimetallic type, with phase unbalance protection (differential). Direct mounting on the bottom terminals of a Tesys contactor LC1D40A-D65A to form a compact starter. Light and compact, 55mm wide. Temperature compensated for a good accuracy of the protection. Manual control with test & reset buttons, manual / automatic reset selector. Trip signaling with 1NO+1NC auxiliary contacts and trip flag indicator. Can be completed with terminal blocks for separate mounting (LAD7B, LAD96) and remote control devices (LAD703, LA7D03).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • UI Rated Insulation Voltage : power circuit 600 V CSA, power circuit 600 V UL, power circuit 690 V IEC 60947-4-1
    • UE Rated Operational Voltage : 690 V AC 0...400 Hz power circuit IEC 60947-4-1
    • UIMP Rated Impulse Withstand Voltage : 6 kV
  • Important Information Attributes
    • Associated Fuse Rating : 4 A gG for signalling circuit, 4 A BS for signalling circuit
    • Control Type : Red push-button stop, Blue push-button reset
    • Mechanical Robustness : shocks15 Gn for 11 ms IEC 60068-2-7, vibrations4 gn IEC 60068-2-6
    • Mounting Support : plate, with specific accessories, rail, with specific accessories, under contactor
    • Network Type : DC, AC
    • Permissible Current : 3 A 120 V AC-15 signalling circuit, 0.22 A 125 V DC-13 signalling circuit
    • Range : TeSys, TeSys Deca
    • Tightening Torque : control circuit 1.7 N.m screw clamp terminals, power circuit 5 N.m EverLink BTR screw connectors
    • Carbon Footprint Of The Distribution Phase A4 : 0.532707701, 0.5 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.9 kg CO2 eq., 0.871212274
    • Carbon Footprint Of The Installation Phase A5 : 0.060948491, 0.1 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 0.5 kg CO2 eq., 0.45216814
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 2 kg CO2 eq., 1.896335784
    • Connections Terminals : control circuit screw clamp terminals 2 1-2.5 mm² flexible without cable end, control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end, control circuit screw clamp terminals 2 1-2.5 mm² solid without cable end, power circuit EverLink BTR screw connectors 1 1-35 mm² flexible without cable end, power circuit EverLink BTR screw connectors 1 1-35 mm² flexible with cable end, power circuit EverLink BTR screw connectors 1 1-35 mm² solid without cable end
    • Auxiliaries : LAD703B, LAD703E, LAD703F, LAD703M, LAD96560
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-16
    • HTML Description : TeSys LRD thermal overload relays - 9...13 A - class 20
    • Manufacturer : Schneider Electric
    • Device Type : Relay, Control & Measurement - Protection relay
    • Serviceability : No
    • Traceability : No
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI0804005
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant
    • ROHS EUR Full Compliance Status : Compliant
    • ROHS EUR Full Compliance Status Id : COMPLIANT
    • China ROHS In Scope : No
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • WD Status : 5 - INITIALIZED WITH DataSCAN OK (Migration)
    • Compatibility Code : LRD
    • Device Short Name : LRD
    • Dielectric Strength : 1.89 kV 50 Hz IEC 60947-1
    • Flame Retardance : V1 conforming to UL 94
    • Package Weight Lbs : 0.41 kg
    • Phase Failure Sensitivity : tripping current 130 % of Ir on two phase, the last one at 0
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : differential thermal overload relay
    • Relay Application : motor protection
    • Returnability : No
    • Sustainable Packaging : Yes
    • Temperature Compensation : -20-60 °C
    • Thermal Overload Class : class 20 IEC 60947-4-1
    • Total Lifecycle Carbon Footprint : 4 kg CO2 eq.
    • Tripping Threshold : 1.14 +/- 0.06 Ir IEC 60947-4-1
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • ITH Conventional Free Air Thermal Current : 5 A signalling circuit
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP0804005EN
    • Pep Verification Date : 2024-06-01
    • PCR Version : PCR-4-ed4-EN-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : The functional unit of the LRD365 is to detect overload currents in order to protect the load for 20 years.
    • Functional Unit Unit : unit
    • Product Kit Identifier : N
    • Product Manager : LIHUA CHEN
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -20-60 °C without derating IEC 60947-4-1, -20-60 °C without derating IEC 60947-4-1, -20-60 °C without derating IEC 60947-4-1
    • EU ROHS Directive : Compliant​, Compliant
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Reach Free SHVC : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 3.81337239
    • Circularity Profile : ENVEOLI0804005
    • Climatic Withstand : IACS E10
    • Environmental Disclosure : ENVPEP0804005EN
    • IP Degree Of Protection : IP20 conforming to IEC 60529
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of SVHC : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP0804005EN
    • Pep Verification Date : 2024-06-01
    • PCR Version : PCR-4-ed4-EN-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : differential thermal overload relay
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months