TeSys Deca thermal overload relays - 0.4...0.63 A - class 20

TeSys Deca thermal overload relays - 0.4...0.63 A - class 20

SQDLRD04L6 LRD04L6 3606480609763
75.86 / EA
http://schema.org/OutOfStock
  • Dielectric Strength: 1.89 kV, 50 Hz
  • Warranty Length: 18 mth
TeSys LRD thermal overload relay, 0.63A/690V, thermal setting range 0.4-0.63A, tripping class 10A, for protection of 3-phase motors 0.12-0.18kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine).
QTY
  • Product Description
  • Features
  • Specifications
TeSys LRD thermal overload relay, 0.63A/690V, thermal setting range 0.4-0.63A, tripping class 10A, for protection of 3-phase motors 0.12-0.18kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine).
  • Prop 65
    • WARNING: Cancer - www.P65Warnings.ca.gov
  • Complementary Attributes
    • UI Rated Insulation Voltage : power circuit 600 V CSA, power circuit 600 V UL, power circuit 690 V IEC 60947-4-1
    • UE Rated Operational Voltage : 690 V AC 0...400 Hz power circuit IEC 60947-4-1
    • UIMP Rated Impulse Withstand Voltage : 6 kV
  • Important Information Attributes
    • Associated Fuse Rating : 4 A gG for signalling circuit, 4 A BS for signalling circuit
    • Control Type : Red push-button stop, Blue push-button reset
    • Mechanical Robustness : shocks15 Gn for 11 ms IEC 60068-2-7, vibrations3 GN IEC 60068-2-6
    • Mounting Support : plate, with specific accessories, rail, with specific accessories, under contactor
    • Network Type : DC, AC
    • Permissible Current : 3 A 120 V AC-15 signalling circuit, 0.22 A 125 V DC-13 signalling circuit
    • Range : TeSys, TeSys Deca
    • Tightening Torque : control circuit 1.7 N.m screw clamp terminals, power circuit 2.3 N.m lugs-ring terminals M4
    • Carbon Footprint Of The Distribution Phase A4 : 0.024163479198025903, 0 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.2 kg CO2 eq., 0.21678519324421383
    • Carbon Footprint Of The Installation Phase A5 : 0.01635889814277638, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 1 kg CO2 eq., 1.0267614686619415
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 12 kg CO2 eq., 11.633004615445152
    • Connections Terminals : control circuit screw clamp terminals 2 1-2.5 mm² flexible without cable end, control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end, control circuit screw clamp terminals 2 1-2.5 mm² solid without cable end, power circuit lugs-ring terminals
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-05-31
    • Device Type : Relay, Control & Measurement - Protection relay
    • Serviceability : No
    • Traceability : No
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI0802006
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant
    • ROHS EUR Full Compliance Status : Compliant
    • ROHS EUR Full Compliance Status Id : COMPLIANT
    • China ROHS In Scope : No
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • WD Status : 2 - SELECTED (Migration)
    • Compatibility Code : LRD
    • Device Short Name : LRD
    • Dielectric Strength : 1.89 kV 50 Hz IEC 60947-1
    • Package Weight Lbs : 144.0 g
    • Phase Failure Sensitivity : tripping current 130 % of Ir on two phase, the last one at 0
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : differential thermal overload relay
    • Relay Application : motor protection
    • Returnability : No
    • Sustainable Packaging : Yes
    • Temperature Compensation : -20-60 °C
    • Thermal Overload Class : class 20 IEC 60947-4-1
    • Total Lifecycle Carbon Footprint : 13 kg CO2 eq.
    • Tripping Threshold : 1.14 +/- 0.06 Ir IEC 60947-4-1
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • ITH Conventional Free Air Thermal Current : 5 A signalling circuit
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP0802006EN
    • Pep Verification Date : 2025-08-05
    • PCR Version : PCR-4-ed4-EN-2021 09 06
    • PSR Version : PSR-0005-ed3-EN-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : Other switchgear and controlgear solutions mentioned in the scope (e.g. fuses TC32, all-or-nothing relays TC94, Measuring relays and protection equipment TC95), apply the general rules of PCR and mention in the accompanying report the functional unit, the reference product characteristics, the reference lifetime and the use scenario which are applied consistently with the relevant IEC technical standards.
    • Functional Unit Unit : unit
    • Product Kit Identifier : N
    • Product Manager : LIHUA CHEN
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -20-60 °C without derating IEC 60947-4-1, -20-60 °C without derating IEC 60947-4-1, -20-60 °C without derating IEC 60947-4-1
    • EU ROHS Directive : Compliant​, Compliant
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Reach Free SHVC : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 12.917073654692109
    • Circularity Profile : ENVEOLI0802006
    • Climatic Withstand : IACS E10
    • Environmental Disclosure : ENVPEP0802006EN
    • IP Degree Of Protection : IP20 conforming to IEC 60529
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of SVHC : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP0802006EN
    • Pep Verification Date : 2025-08-05
    • PCR Version : PCR-4-ed4-EN-2021 09 06
    • PSR Version : PSR-0005-ed3-EN-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : differential thermal overload relay
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months