Differential thermal overload relays, TeSys K, 0.11 to 0.16A, class 10A

OVERLOAD RELAY

SQDLR2K0301 LR2K0301 3389110230352
86.71 / EA
http://schema.org/OutOfStock
  • Depth: 65 mm
  • Warranty Length: 18 mth
LR2K0301 is a TeSys LRK thermal overload relay from Schneider Electric to be used with a TeSys K contactors. It protects motors less than 0.06kW@400V thanks to a thermal range 0.11-0.16A, a tripping class 10A and phase unbalance protection. LR2K0301 is a TeSys LRK thermal overload relay from Schneider Electric for direct mounting on TeSys K contactors. With a thermal setting range 0.11-0.16A, a tripping class 10A and phase unbalance detection, it protects motors less than 0.06kW@400V. It provides manual test & reset buttons, automatic reset, trip auxiliary contact and flag indicator. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine). Thermal overload protection relay, bimetallic type, with phase unbalance protection (differential). Direct mounting on the bottom terminals of a Tesys contactor LC1K06 to form a compact starter. Light and compact, 45mm wide. Manual control with test & reset buttons, manual / automatic reset selector. Trip signaling with 1NO+1NC auxiliary contacts and trip flag indicator. Can be completed with terminal blocks for separate mounting (LA7K0064).
QTY
  • Product Description
  • Features
  • Specifications
LR2K0301 is a TeSys LRK thermal overload relay from Schneider Electric to be used with a TeSys K contactors. It protects motors less than 0.06kW@400V thanks to a thermal range 0.11-0.16A, a tripping class 10A and phase unbalance protection. LR2K0301 is a TeSys LRK thermal overload relay from Schneider Electric for direct mounting on TeSys K contactors. With a thermal setting range 0.11-0.16A, a tripping class 10A and phase unbalance detection, it protects motors less than 0.06kW@400V. It provides manual test & reset buttons, automatic reset, trip auxiliary contact and flag indicator. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine). Thermal overload protection relay, bimetallic type, with phase unbalance protection (differential). Direct mounting on the bottom terminals of a Tesys contactor LC1K06 to form a compact starter. Light and compact, 45mm wide. Manual control with test & reset buttons, manual / automatic reset selector. Trip signaling with 1NO+1NC auxiliary contacts and trip flag indicator. Can be completed with terminal blocks for separate mounting (LA7K0064).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Product Certifications : UL, CSA, UKCA
    • Standards : VDE 0660, IEC 60947, NF C 63-650, BS 4941
  • Complementary Attributes
    • Ue Rated Operational Voltage : <= 690 V power circuit, <= 690 V power circuit, <= 690 V power circuit, <= 690 V power circuit, 690 V AC AC-15 signalling circuit, 250 V DC DC-13 signalling circuit
    • Ui Rated Insulation Voltage : power circuit 690 V BS 4941, power circuit 690 V IEC 60947, power circuit 750 V VDE 0110 group C, power circuit 600 V CSA C22.2 No 14
    • Uimp Rated Impulse Withstand Voltage : 6 kV
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SC
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Associated Fuse Rating : 6 A gG for signalling circuit conforming to VDE 0660, 6 A gG for signalling circuit conforming to IEC 60947
    • Control Type : Red push-button trip test function, Blue push-button stop and manual reset, selector switch manual or automatic reset
    • Flame Retardance : V1 conforming to UL 94, requirement 2 conforming to NF F 16-101, requirement 2 conforming to NF F 16-102
    • Mechanical Robustness : vibrations NC contact2 Gn, 5...300 Hz IEC 60068-2-6, shocks NO contact10 Gn for 11 ms IEC 60068-2-27, shocks NC contact10 Gn for 11 ms IEC 60068-2-27, vibrations NO contact2 Gn, 5...300 Hz IEC 60068-2-6
    • Mounting Support : under contactor, plate, with specific accessories, rail, with specific accessories
    • Network Type : DC, AC
    • Protective Treatment : TC IEC 60068, TC DIN 50016
    • Tightening Torque : 1.3 N.m screw clamp terminals Philips No 2, 1.3 N.m screw clamp terminals flat Ø 6 mm, 1.3 N.m screw clamp terminals pozidriv No 2
    • Connections Terminals : screw clamp terminals 2 0.75-4 mm²flexible without cable end, screw clamp terminals 2 0.34-1.5 mm²flexible with cable end, screw clamp terminals 1 1.5-4 mm²solid, screw clamp terminals 2 1.5-4 mm²solid, screw clamp terminals 1 0.75-4 mm²flexible without cable end, screw clamp terminals 1 0.34-2.5 mm²flexible with cable end
    • Carbon Footprint Of The Distribution Phase A4 : 0.017124164486850613, 0 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.3570299549275095, 0.4 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0 kg CO2 eq., 0.043940103606662645
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 0.9 kg CO2 eq., 0.8931643852450023
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 5 kg CO2 eq., 4.986699999999999
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-09-13
    • Global Commercial Status : Commercialised
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Device Type : Relay, Control & Measurement - Protection relay
    • Serviceability : No
    • Traceability : No
    • Legacy Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2211018
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Conformity Date : 0702
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : No
    • China Rohs Label : 1
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 2
    • Tier : 2
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Compatibility Code : LR2K
    • Device Short Name : LR2K
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Local Signalling : trip indicator Yellow)
    • Network Frequency : <= 400 Hz
    • Phase Failure Sensitivity : yes IEC 60947-4-1
    • Power Dissipation Per Pole : 2 W
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Name : TeSys LRK
    • Product Or Component Type : differential thermal overload relay
    • Range : TeSys
    • Range Of Product : TeSys K thermal overload relays
    • Relay Application : motor protection
    • Returnability : No
    • Software Version : v5.9.4
    • Sustainable Packaging : Yes
    • Thermal Overload Class : class 10A IEC 60947-4-1
    • Thermal Protection Adjustment Range : 0.11-0.16 A
    • Total Lifecycle Carbon Footprint : 6 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Ith Conventional Free Air Thermal Current : 6 A signalling circuit
    • Warranty In Months : 18
    • R Thermal Protection Adj Range : 0.11-0.16 A
    • Pep Code : ENVPEP2211018EN
    • Database Version : 2022-01
    • Pep Verification Date : 2025-08-05
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : Turn off all or part of an installation by separating the installation or part of the installation of all electrical energy or earth, for safety reasons with a rated voltage 690V and rated current 20A ensuring isolation characterized by rated voltage 6KV. This function is provided for 20 years.
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Product Weight In G2 : 145
    • Reference Lifetime In Y2 : 20
    • Energy Consumption On Product Lifetime In Kwh : 74.6352
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Production mix; Low voltage; CZ
    • Energy Model Installation A5 2 : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model Use B6 2 : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model End Of Life C1 C4 2 : Electricity Mix; Production mix; Low voltage; FR
    • Recyclability Potential In 2 : 42
    • Offer Owner Code : 190788
    • Height Nominal : 58 mm
    • Width Nominal : 45 mm
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Ambient Air Temperature For Operation : -20-55 °C without derating IEC 60947, -20-55 °C without derating IEC 60947, -20-55 °C without derating IEC 60947, -30-60 °C with derating IEC 60947, -30-60 °C with derating IEC 60947, -30-60 °C with derating IEC 60947, -20-55 °C without derating IEC 60947, -20-55 °C without derating IEC 60947, -20-55 °C without derating IEC 60947, -30-60 °C with derating IEC 60947, -30-60 °C with derating IEC 60947
    • Product Compatibility : LP4K, LC1K, LP1K, LC7K
    • Take Back : Nej
    • Reach Free Shvc : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 6.297958608266024
    • Ambient Air Temperature For Storage : -40-70 °C
    • Circularity Profile : ENVEOLI2211018
    • Environmental Disclosure : ENVPEP2211018EN
    • Eu Rohs Directive : Compliant
    • Ip Degree Of Protection : IP2X conforming to IEC 60529
    • Operating Altitude : 6561.68 ft (2000 m) without derating
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2211018EN
    • Pep Verification Date : 2025-08-05
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : differential thermal overload relay
    • Range Of Product : TeSys K thermal overload relays
  • ETIM
    • ETIM 8 : EC000106
    • ETIM 9 : EC000106
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Depth : 65 mm