TeSys Deca thermal overload relays , 5.5...8A , class 20

TeSys Deca thermal overload re

SQDLRD1512 LRD1512 3389110146707
99.44 / EA
http://schema.org/OutOfStock
  • Country of Origin: USA
  • Depth: 92 mm
  • Dielectric Strength: 1.89 kV, 50 Hz
  • Net Weight: 0.19 kg
  • Warranty Length: 18 mth
  • Weight: 0.19 kg
  • Width: 45 mm
TeSys LRD thermal overload relay, 8A/690V, thermal setting range 5.5-8A, tripping class 20, for protection of 3-phase motors 3kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustment dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signaling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B105 (to be ordered separately). Multi standards certified (IEC, UL, CSA, Marine).
QTY
  • Product Description
  • Features
  • Specifications
TeSys LRD thermal overload relay, 8A/690V, thermal setting range 5.5-8A, tripping class 20, for protection of 3-phase motors 3kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustment dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signaling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B105 (to be ordered separately). Multi standards certified (IEC, UL, CSA, Marine).
  • Prop 65
    • WARNING: Cancer - www.P65Warnings.ca.gov
  • Environment
    • Product Certifications : IEC || UL || CSA || EAC || DNV-GL || LROS (Lloyds register of shipping) || UKCA
    • Mechanical Robustness : vibrations6 Gn IEC 60068-2-6 || shocks15 Gn for 11 ms IEC 60068-2-7
    • Standards : EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1
    • Climatic Withstand : IACS E10
    • Ambient Air Temperature For Operation : -20-60 °C without derating IEC 60947-4-1
    • Dielectric Strength : 1.89 kV 50 Hz IEC 60947-1
    • Ip Degree Of Protection : IP20 conforming to IEC 60529
    • Flame Retardance : V1 conforming to UL 94
    • Ambient Air Temperature For Storage : -60-70 °C
    • Fire Resistance : 850 °C IEC 60695-2-1
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Packaging Made With Recycled Cardboard : Yes
    • Environmental Disclosure : ENVPEP110101EN
    • Packaging Without Single Use Plastic : Yes
    • Scip Number : 224fb0ea-2bc1-482e-b6b4-c1bdd9779659
    • California Proposition 65 : WARNING: Cancer - www.P65Warnings.ca.gov
    • Circularity Profile : ENVEOLI1101001
    • Take-Back : No
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 4.2988624398
  • Complementary
    • Network Frequency : 0...400 Hz
    • [Ith] Conventional Free Air Thermal Current : 5 A signalling circuit
    • Auxiliary Contact Composition : 1 NO + 1 NC
    • Connections - Terminals : control circuit screw clamp terminals 2 1-2.5 mm² flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm² solid without cable end || power circuit screw clamp terminals 1 1.5-10 mm² flexible without cable end || power circuit screw clamp terminals 1 1-4 mm² flexible with cable end || power circuit screw clamp terminals 1 1-6 mm² solid without cable end
    • Phase Failure Sensitivity : tripping current 130 % of Ir on two phase, the last one at 0
    • [Ue] Rated Operational Voltage : 690 V AC 0...400 Hz power circuit IEC 60947-4-1
    • Associated Fuse Rating : 4 A gG for signalling circuit || 4 A BS for signalling circuit
    • Net Weight : 0.19 kg
    • [Uimp] Rated Impulse Withstand Voltage : 6 kV
    • Permissible Current : 1.5 A 240 V AC-15 signalling circuit || 0.1 A 250 V DC-13 signalling circuit
    • Tripping Threshold : 1.14 +/- 0.06 Ir IEC 60947-4-1
    • Tightening Torque : control circuit 1.7 N.m screw clamp terminals || power circuit 1.85 N.m screw clamp terminals
    • Control Type : Red push-button stop || Blue push-button reset
    • Mounting Support : plate, with specific accessories || rail, with specific accessories || under contactor
    • Width : 45 mm
    • Depth : 92 mm
    • Temperature Compensation : -20-60 °C
  • Specifications
    • Country of Origin : United States
    • Width : 45 mm
    • Weight : 0.19 kg
    • Network Type : DC || AC
    • Thermal Protection Adjustment Range : 5.5-8 A
    • Relay Application : motor protection
    • Product Or Component Type : differential thermal overload relay
    • Product Name : TeSys LRD || TeSys Deca
    • Thermal Overload Class : class 20 IEC 60947-4-1
    • Range : TeSys
    • [Ui] Rated Insulation Voltage : power circuit 600 V CSA || power circuit 600 V UL || power circuit 690 V IEC 60947-4-1
    • Product Compatibility : LC1D12 || LC1D25 || LC1D18 || LC1D32 || LC1D09
    • Device Short Name : LRD