TeSys Deca differential thermal overload relay 62-80A class10A EverLink+springs

TESYS DECA DIFFERENTIAL THERMA

SQDLRD3803 LRD3803 3606481311993
130.43 / EA
http://schema.org/OutOfStock
  • Country of Origin: France
  • Depth: 123 mm
  • Dielectric Strength: 1.89 kV, 50 Hz
  • Height: 70 mm
  • Net Weight: 0.375 kg
  • Warranty Length: 18 mth
  • Weight: 0.375 kg
  • Width: 55 mm
TeSys LRD thermal overload relay, 80A/690V, thermal setting range 62-80A, tripping class 10A, for protection of 3-phase motors 37kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by EverLink BTR screw terminals , it connects directly to the bottom terminals of 3-pole contactors LC1D40A-D80A. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD96560 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).
QTY
  • Product Description
  • Specifications
TeSys LRD thermal overload relay, 80A/690V, thermal setting range 62-80A, tripping class 10A, for protection of 3-phase motors 37kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by EverLink BTR screw terminals , it connects directly to the bottom terminals of 3-pole contactors LC1D40A-D80A. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD96560 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).
  • Environment
    • Product Certifications : IEC || UL || CSA || CCC || EAC || DNV-GL || RMRS || EU-RO MR || UKCA
    • Mechanical Robustness : shocks15 Gn for 11 ms IEC 60068-2-7 || vibrations3 GN IEC 60068-2-6
    • Standards : EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4 || GB/T 14048.5
    • Climatic Withstand : IACS E10
    • Ambient Air Temperature For Operation : -20-60 °C without derating IEC 60947-4-1
    • Dielectric Strength : 1.89 kV 50 Hz IEC 60947-1
    • Ip Degree Of Protection : IP20 conforming to IEC 60529
    • Flame Retardance : V1 conforming to UL 94
    • Ambient Air Temperature For Storage : -60-70 °C
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP110101EN
    • Packaging Without Single Use Plastic : Yes
    • Toxic Heavy Metal Free : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Reach Free Of Svhc : Yes
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Circularity Profile : ENVEOLI1101001
    • Take-Back : No
    • Sustainable Packaging : Yes
    • Eu Rohs Directive : Compliant
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 5.2012005979
  • Complementary
    • Network Frequency : 0...400 Hz
    • Height : 70 mm
    • [Ith] Conventional Free Air Thermal Current : 5 A signalling circuit
    • Auxiliary Contact Composition : 1 NO + 1 NC
    • Connections - Terminals : power circuit EverLink BTR screw connectors 1 1-35 mm² flexible with cable end || power circuit EverLink BTR screw connectors 1 1-35 mm² solid || control circuit spring terminals 1 1-2.5 mm² solid || power circuit EverLink BTR screw connectors 1 1-35 mm² flexible || power circuit direct terminal link top || control circuit spring terminals 1 1-2.5 mm² flexible
    • Phase Failure Sensitivity : tripping current 130 % of Ir on two phase, the last one at 0
    • [Ue] Rated Operational Voltage : 690 V AC 0...400 Hz power circuit IEC 60947-4-1
    • Associated Fuse Rating : 4 A gG for signalling circuit || 4 A BS for signalling circuit
    • Net Weight : 0.375 kg
    • [Uimp] Rated Impulse Withstand Voltage : 6 kV
    • Power Dissipation Per Pole : 4.8 W
    • Permissible Current : 0.95 A 380 V AC-15 signalling circuit || 0.06 A 440 V DC-13 signalling circuit
    • Tripping Threshold : 1.14 +/- 0.06 Ir IEC 60947-4-1
    • Tightening Torque : power circuit 5 N.m EverLink BTR screw connectors 25-25 mm² || power circuit 8 N.m EverLink BTR screw connectors 35-35 mm²
    • Control Type : Red push-button stop || Blue push-button reset
    • Mounting Support : plate, with terminal block LAD96560 on top || rail, with terminal block LAD96560 on top || direct mounting under contactor
    • Width : 55 mm
    • Depth : 123 mm
    • Temperature Compensation : -20-60 °C
  • Specifications
    • Country of Origin : France
    • Width : 55 mm
    • Height : 70 mm
    • Weight : 0.375 kg
    • Network Type : AC || DC
    • Thermal Protection Adjustment Range : 62-80 A
    • Relay Application : motor protection
    • Product Or Component Type : differential thermal overload relay
    • Product Name : TeSys LRD || TeSys Deca
    • Thermal Overload Class : class 10A IEC 60947-4-1
    • Range : TeSys || TeSys Deca
    • [Ui] Rated Insulation Voltage : power circuit 690 V IEC 60947-4-1 || power circuit 600 V UL 60947-4-1 || power circuit 600 V CSA C22.2 No 14
    • Product Compatibility : LC1D80A
    • Device Short Name : LRD