Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 80A, 600V AC 60Hz coil, screw clamp terminals

contactor, TeSys Deca, 3P(3NO)

SQDLC1D80X6 LC1D80X6 3389110443189
410.99 / EA
http://schema.org/OutOfStock
  • Country of Origin: Czechia
  • Depth: 130 mm
  • Height: 127 mm
  • Net Weight: 1.59 kg
  • Warranty Length: 18 mth
  • Weight: 1.59 kg
  • Width: 85 mm
TeSys Deca contactor, 3P(3NO) for category AC-3/AC-3e applications up to 80A @440V. It provides with 600V 60 Hz coil, with 1NO+1NC auxiliary contacts, power and control connections by screw clamp terminals. It procures high reliability and durability with 10 Mcycles mechanical durability and 1.5 Mcycles electrical durability. It provides IP20 protection on front face conforming to IEC 60529. It can cover -40°C to 60°C operation temperature and without derating under 3000m altitude. Designed for demanding applications with maximum operating rates up to 3600 cycles per hour under maximum 60°C. The dimension is 127mm x 85mm x 130mm (H x W x D), mounting on rail or plate. Multi standards certified(CCC,CSA,UL,GOST,BV,RINA,DNV,LROS,GL).
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca contactor, 3P(3NO) for category AC-3/AC-3e applications up to 80A @440V. It provides with 600V 60 Hz coil, with 1NO+1NC auxiliary contacts, power and control connections by screw clamp terminals. It procures high reliability and durability with 10 Mcycles mechanical durability and 1.5 Mcycles electrical durability. It provides IP20 protection on front face conforming to IEC 60529. It can cover -40°C to 60°C operation temperature and without derating under 3000m altitude. Designed for demanding applications with maximum operating rates up to 3600 cycles per hour under maximum 60°C. The dimension is 127mm x 85mm x 130mm (H x W x D), mounting on rail or plate. Multi standards certified(CCC,CSA,UL,GOST,BV,RINA,DNV,LROS,GL).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Product Certifications : CCC || UL || CB Scheme || CSA || CE || UKCA || Marine || EAC
    • Net Weight : 1.59 kg
    • Flame Retardance : V1 conforming to UL 94
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Width : 85 mm
    • Depth : 130 mm
    • Permissible Ambient Air Temperature Around The Device : -40-60 °C || 60-70 °C with derating
    • Height : 127 mm
    • Standards : EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || CSA C22.2 No 14 || UL 60947-4-1 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || IEC 60335-1:Clause 30.2
    • Climatic Withstand : IACS E10 exposure to damp heat
    • Protective Treatment : THIEC 60068-2-30
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Mechanical Robustness : vibrations contactor open 2 Gn, 5...300 Hz) || shocks contactor open 8 Gn for 11 ms) || vibrations contactor closed 3 Gn, 5...300 Hz) || shocks contactor closed 10 Gn for 11 ms)
    • Fire Resistance : 850 °C IEC 60695-2-1
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Mercury Free : Yes
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Reach Free Of Svhc : Yes
    • Take-Back : No
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 10.960713361237987
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 97 kg CO2 eq.
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 96.78493088326958
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Environmental Disclosure : ENVPEP110205EN
    • Packaging Without Single Use Plastic : Yes
    • Toxic Heavy Metal Free : Yes
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Carbon Footprint Of The Installation Phase [A5] : 0.31002666931072853
    • Circularity Profile : N/A
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 81.20896739130431
    • Carbon Footprint Of The End-Of-Life Phase [C1 To C4] : 4 kg CO2 eq.
    • Carbon Footprint Of The Distribution Phase [A4] : 0.2 kg CO2 eq.
    • Pvc Free : Yes
    • Eu Rohs Directive : Compliant
  • Complementary
    • Non-Overlap Time : 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
    • Minimum Switching Current : 5 mA for signalling circuit
    • Power Dissipation Per Pole : 5.1 W AC-3 || 12.5 W AC-1 || 5.1 W AC-3e
    • Average Impedance : 0.8 mOhm - Ith 125 A 50 Hz for power circuit
    • Auxiliary Contact Composition : 1 NO + 1 NC
    • Mounting Support : rail || plate
    • Insulation Resistance : > 10 MOhm for signalling circuit
    • Inrush Power In Va : 220-220 VA 60 Hz cos phi 0.75 (at 20 °C)
    • [Uimp] Rated Impulse Withstand Voltage : 8 kV IEC 60947
    • Pole Contact Composition : 3 NO
    • Connections - Terminals : control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end || power circuit: connector 1 4-50 mm² - cable stiffness: flexible without cable end || power circuit: connector 2 4-25 mm² - cable stiffness: flexible without cable end || power circuit: connector 1 4-50 mm² - cable stiffness: flexible with cable end || power circuit: connector 2 4-16 mm² - cable stiffness: flexible with cable end || power circuit: connector 1 4-50 mm² - cable stiffness: solid without cable end || power circuit: connector 2 4-25 mm² - cable stiffness: solid without cable end
    • Coil Technology : without built-in suppressor module
    • Maximum Operating Rate : 3600 cyc/h at 60 °C
    • Auxiliary Contacts Type : mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
    • Hold-In Power Consumption In Va : 22-22 VA 60 Hz cos phi 0.3 (at 20 °C)
    • Overvoltage Category : III
    • Maximum Horse Power Rating : 7.5 hp at 120 V AC 50/60 Hz for 1 phase motors || 15 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 30 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 30 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 60 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 60 hp at 575/600 V AC 50/60 Hz for 3 phase motors
    • Motor Power Kw : 22 kW at 220...230 V AC 50/60 Hz (AC-3) || 37 kW at 380...400 V AC 50/60 Hz (AC-3) || 45 kW at 415...440 V AC 50/60 Hz (AC-3) || 55 kW at 500 V AC 50/60 Hz (AC-3) || 45 kW at 660...690 V AC 50/60 Hz (AC-3) || 15 kW at 400 V AC 50/60 Hz (AC-4) || 22 kW at 220...230 V AC 50/60 Hz (AC-3e) || 37 kW at 380...400 V AC 50/60 Hz (AC-3e) || 45 kW at 415...440 V AC 50/60 Hz (AC-3e) || 55 kW at 500 V AC 50/60 Hz (AC-3e) || 45 kW at 660...690 V AC 50/60 Hz (AC-3e)
    • [Ui] Rated Insulation Voltage : power circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL
    • Protective Cover : with
    • [Ith] Conventional Free Air Thermal Current : 10 A (at 60 °C) for signalling circuit || 125 A (at 60 °C) for power circuit
    • Control Circuit Voltage Limits : 0.85...1.1 Uc (-40-55 °C):operational AC 60 Hz || 0.3...0.6 Uc (-40-70 °C):drop-out AC 60 Hz || 1...1.1 Uc (55-70 °C):operational AC 60 Hz
    • Control Circuit Type : AC 60 Hz
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Pollution Degree : 3
    • Rated Breaking Capacity : 1100 A at 440 V for power circuit conforming to IEC 60947
    • Irms Rated Making Capacity : 140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1 || 1100 A at 440 V for power circuit conforming to IEC 60947
    • Associated Fuse Rating : 10 A gG for signalling circuit conforming to IEC 60947-5-1 || 200 A gG at <= 690 V coordination type 1 for power circuit || 160 A gG at <= 690 V coordination type 2 for power circuit
    • Operating Time : 20...35 ms closing || 6...20 ms opening
    • Minimum Switching Voltage : 17 V for signalling circuit
    • Signalling Circuit Frequency : 25...400 Hz
    • Tightening Torque : control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector flat Ø 6 to Ø 8 mm || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.m screw clamp terminals pozidriv No 2
    • Electrical Durability : 0.8 Mcycles 125 A AC-1 <= 440 V || 1.5 Mcycles 80 A AC-3 <= 440 V || 1.5 Mcycles 80 A AC-3e <= 440 V
    • Mechanical Durability : 10 Mcycles
    • Compatibility Code : LC1D
    • [Icw] Rated Short-Time Withstand Current : 640 A 40 °C - 10 s for power circuit || 990 A 40 °C - 1 s for power circuit || 135 A 40 °C - 10 min for power circuit || 320 A 40 °C - 1 min for power circuit || 100 A - 1 s for signalling circuit || 120 A - 500 ms for signalling circuit || 140 A - 100 ms for signalling circuit
    • Heat Dissipation : 6-10 W at 60 Hz
  • Specifications
    • Country of Origin : Czechia
    • Width : 85 mm
    • Height : 127 mm
    • Weight : 1.59 kg
    • [Uc] Control Circuit Voltage : 600 V AC 60 Hz
    • [Ue] Rated Operational Voltage : power circuit <= 300 V DC 25...400 Hz || power circuit <= 690 V AC
    • Contactor Application : motor control || resistive load
    • Product Or Component Type : contactor
    • Utilisation Category : AC-3 || AC-3e || AC-4 || AC-1
    • [Ie] Rated Operational Current : 125 A (at <60 °C) at <= 1000 V AC AC-1 for power circuit || 80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 80 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    • Poles Description : 3P
    • Range Of Product : TeSys Deca
    • Range : TeSys
    • Device Short Name : LC1D