SQUARE D

Reversing contactor, TeSys Deca Advanced, 3P(3NO), AC-3/3e, <=440V, 40A, 48...130V AC/DC coil, EverLink BTR screws

TESYS DECA REVERSING CONTACTOR

SQDLC2D40AEHE LC2D40AEHE SQDLC2D40AEHE
352.12 / EA
http://schema.org/OutOfStock
  • Depth: 120 mm
  • Warranty Length: 18 mth
LC2D40AEHE is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 40A AC-3 18.5kW@400V, it includes a 48-130V AC/DC low consumption electronic coil, 2NO+2NC aux contacts, a mechanical interlock. LC2D40AEHE is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 18.5kW@400V. It includes a 48-130V AC/DC low consumption electronic coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 119mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with an electronic coil, wide band voltage 48-130V, AC/DC compatible, low consumption. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 1.6 million cycles at 40A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Power connections by EverLink BTR screw terminals providing constant tightening pressure.
QTY
  • Specifications
  • Physical Attributes
    • Color : Gray SE GREY 6), Green SE GREEN 2)
  • Complementary Attributes
    • Control Circuit Type : AC 50/60 Hz AC/DC electronic, DC AC/DC electronic, AC 50/60 Hz AC/DC electronicDC AC/DC electronic
    • Control Circuit Voltage Limits : <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, 0.85...1.1 Uc (-40-60 °C):operational AC/DC, 1...1.1 Uc (60-70 °C):operational AC/DC
    • Irms Rated Making Capacity : 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 800 A at 440 V for power circuit conforming to IEC 60947
    • Maximum Horse Power Rating : 10 hp at 230/240 V AC 60 Hz for 3 phase motors, 3 hp at 115 V AC 60 Hz for 1 phase motors, 5 hp at 230/240 V AC 60 Hz for 1 phase motors, 10 hp at 200/208 V AC 60 Hz for 3 phase motors, 30 hp at 460/480 V AC 60 Hz for 3 phase motors, 30 hp at 575/600 V AC 60 Hz for 3 phase motors
    • Icw Rated Short Time Withstand Current : 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit, 320 A 40 °C - 10 s for power circuit, 720 A 40 °C - 1 s for power circuit, 72 A 40 °C - 10 min for power circuit, 165 A 40 °C - 1 min for power circuit
    • Ie Rated Operational Current : 60 A (at <60 °C) at <= 440 V AC-1 for power circuit, 40 A (at <60 °C) at <= 440 V AC-3 for power circuit, 40 A (at <60 °C) at <= 440 V AC-3e for power circuit
    • Uc Control Circuit Voltage : 48...130 V, 48...130 V AC 50/60 Hz, 48...130 V DC
    • Ui Rated Insulation Voltage : power circuit 690 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-1
    • Maximum Motor Phase Current : 40 A
    • Maximum Operating Rate : 3600 cyc/h 60 °C
    • Minimum Switching Current : 5 mA for signalling circuit
    • Minimum Switching Voltage : 17 V for signalling circuit
    • Rated Breaking Capacity : 800 A at 440 V for power circuit conforming to IEC 60947
    • Ue Rated Operational Voltage : power circuit 690 V AC 25...400 Hz
    • Uimp Rated Impulse Withstand Voltage : 6 kV IEC 60947
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Associated Fuse Rating : 10 A gG for signalling circuit conforming to IEC 60947-5-1, 80 A gG at <= 690 V coordination type 1 for power circuit, 80 A gG at <= 690 V coordination type 2 for power circuit
    • Contactor Application : motor control, resistive load
    • Insulation Resistance : > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
    • Mechanical Robustness : vibrations contactor open2 Gn, 5...300 Hz, vibrations contactor closed4 Gn, 5...300 Hz, shocks contactor open10 Gn for 11 ms, shocks contactor closed15 Gn for 11 ms
    • Motor Power Kw : 11 kW at 220...230 V AC 50 Hz, 18.5 kW at 380...400 V AC 50 Hz, 22 kW at 415 V AC 50 Hz, 22 kW at 440 V AC 50 Hz, 22 kW at 500 V AC 50 Hz, 30 kW at 660...690 V AC 50 Hz
    • Mounting Support : rail, plate
    • Non Overlap Time : 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
    • Power Dissipation Per Pole : 2.4 W AC-3, 5.4 W AC-1, 2.4 W AC-3e
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Tightening Torque : control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals Philips No 2, power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm, power circuit 5 N.m EverLink BTR screw connectors 1-25 mm² hexagonal 4 mm
    • Utilisation Category : AC-1, AC-3, AC-3e
    • Connections Terminals : control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end, control circuit screw clamp terminals 2 1-4 mm²solid, power circuit EverLink BTR screw connectors 2 1-25 mm²flexible without cable end, power circuit EverLink BTR screw connectors 1 1-35 mm²flexible with cable end, power circuit EverLink BTR screw connectors 2 1-25 mm²flexible with cable end, power circuit EverLink BTR screw connectors 1 1-35 mm²solid, power circuit EverLink BTR screw connectors 2 1-25 mm²solid, control circuit screw clamp terminals 1 1-4 mm²flexible without cable end, control circuit screw clamp terminals 2 1-4 mm²flexible without cable end, control circuit screw clamp terminals 1 1-4 mm²flexible with cable end, control circuit screw clamp terminals 1 1-4 mm²solid, power circuit EverLink BTR screw connectors 1 1-35 mm²flexible without cable end
    • Icw Rated Short Time Withstand Current : 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit, 320 A 40 °C - 10 s for power circuit, 720 A 40 °C - 1 s for power circuit, 72 A 40 °C - 10 min for power circuit, 165 A 40 °C - 1 min for power circuit
    • Ie Rated Operational Current : 60 A (at <60 °C) at <= 440 V AC-1 for power circuit, 40 A (at <60 °C) at <= 440 V AC-3 for power circuit, 40 A (at <60 °C) at <= 440 V AC-3e for power circuit
    • Ith Conventional Free Air Thermal Current : 10 A (at 60 °C) for signalling circuit, 60 A (at 60 °C) for power circuit
    • Carbon Footprint Of The Distribution Phase A4 : 0.22194339884224623, 0.2 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 3.2111256134685835, 3 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0.1 kg CO2 eq., 0.14396868592458148
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 15 kg CO2 eq., 14.707659819861778
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 43 kg CO2 eq., 42.54697020149419
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-01
    • Global Commercial Status : Commercialised
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Legacy Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1607010
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 1929
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : No
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Average Impedance : 1.5 mOhm - Ith 60 A 50 Hz for power circuit
    • Coil Technology : built-in bidirectional peak limiting
    • Compatibility Code : LC2D
    • Device Short Name : LC2D
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Flame Retardance : V1 conforming to UL 94
    • Halogen Free Status : Halogen free plastic parts and cables product
    • Interlocking Type : mechanical
    • Overvoltage Category : III
    • Pole Contact Composition : 3 NO
    • Poles Description : 3P
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Name : TeSys Deca Advanced
    • Product Or Component Type : reversing contactor
    • Protective Treatment : TH IEC 60068-2-30
    • Range Of Product : TeSys Deca Advanced
    • Returnability : No
    • Signalling Circuit Frequency : 25...400 Hz
    • Software Version : v6.2.4
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 61 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Rated Thermal Current Ith : 60 A
    • Warranty In Months : 18
    • Control Circuit Voltage : 48...130 V
    • Inf Motor Phase Current : 40 A
    • Pep Code : ENVPEP1607010EN
    • Database Version : 2024-01
    • Pep Verification Date : 2025-07-25
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Product Weight In G2 : 1838
    • Reference Lifetime In Y2 : 20
    • Energy Consumption On Product Lifetime In Kwh : 473.04
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Low voltage; 2020; France, FR
    • Energy Model Installation A5 2 : No energy used
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2020; France, FR
    • Energy Model End Of Life C1 C4 2 : Global, European and French datasets are used.
    • Recyclability Potential In 2 : 64
    • Offer Owner Code : 190788
    • Height Nominal : 122 mm
    • Width Nominal : 119 mm
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Ambient Air Temperature For Operation : -40-60 °C, -40-60 °C, 60-70 °C with derating
    • Climatic Withstand : IACS E10, IEC 60947-1 Annex Q category D
    • Take Back : Nej
    • Halogene Performance : Halogen free plastic parts & cables product
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 60.83166771959138
    • Ambient Air Temperature For Storage : -60-80 °C
    • Circularity Profile : ENVEOLI1607010
    • Environmental Disclosure : ENVPEP1607010EN
    • Eu Rohs Directive : Compliant By Exemption
    • Halogen Content Performance : Halogen free plastic parts & cables product
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1607010EN
    • Pep Verification Date : 2025-07-25
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : reversing contactor
    • Range Of Product : TeSys Deca Advanced
  • ETIM
    • ETIM 8 : EC000010
    • ETIM 9 : EC000010
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Depth : 120 mm
  • Overview Attributes
    • Device Presentation : preassembled with reversing power busbar