TeSys Deca contactor - 3P(3 NO) - AC-3/AC-3e - <= 440 V 9 A - 48 V DC coil

TeSys Deca contactor - 3P(3 NO

SQDLC1D09EL LC1D09EL 3389110361100
134.84 / EA
http://schema.org/OutOfStock
  • Country of Origin: Indonesia
  • Depth: 95 mm
  • Height: 77 mm
  • Net Weight: 0.48 kg
  • Warranty Length: 18 mth
  • Weight: 0.48 kg
  • Width: 45 mm
TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3/3e (4kW@400V). It provides a low consumption 48V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).
QTY
  • Product Description
  • Specifications
TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3/3e (4kW@400V). It provides a low consumption 48V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).
  • Environment
    • Product Certifications : UL || CCC || CSA || Marine || UKCA || EAC || CB Scheme
    • Net Weight : 0.48 kg
    • Flame Retardance : V1 conforming to UL 94
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Width : 45 mm
    • Depth : 95 mm
    • Permissible Ambient Air Temperature Around The Device : -40-60 °C || 60-70 °C with derating
    • Height : 77 mm
    • Standards : CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 60947-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || CSA C22.2 No 60947-4-1
    • Climatic Withstand : IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
    • Protective Treatment : THIEC 60068-2-30
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Mechanical Robustness : vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
    • Fire Resistance : 850 °C IEC 60695-2-1
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Mercury Free : Yes
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Take-Back : No
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 2.6596552952376262
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 19 kg CO2 eq.
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 19.060481660572194
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Environmental Disclosure : ENVPEP110230EN
    • Packaging Without Single Use Plastic : Yes
    • Toxic Heavy Metal Free : Yes
    • Scip Number : 50ae7612-fd2e-41e4-a369-50d0dea6e592
    • Carbon Footprint Of The Installation Phase [A5] : 0.04070520226073894
    • Circularity Profile : ENVEOLI1102030EN
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 14.925081081081082
    • Carbon Footprint Of The End-Of-Life Phase [C1 To C4] : 1 kg CO2 eq.
    • Carbon Footprint Of The Distribution Phase [A4] : 0.1 kg CO2 eq.
    • Pvc Free : Yes
    • Eu Rohs Directive : Compliant with Exemptions
  • Complementary
    • Non-Overlap Time : 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
    • Minimum Switching Current : 5 mA for signalling circuit
    • Power Dissipation Per Pole : 1.56 W AC-1 || 0.2 W AC-3 || 0.2 W AC-3e
    • Average Impedance : 2.5 mOhm - Ith 25 A 50 Hz for power circuit
    • Auxiliary Contact Composition : 1 NO + 1 NC
    • Mounting Support : rail || plate
    • Hold-In Power Consumption In W : 2.4-2.4 W 20 °C
    • Insulation Resistance : > 10 MOhm for signalling circuit
    • [Uimp] Rated Impulse Withstand Voltage : 6 kV IEC 60947
    • Pole Contact Composition : 3 NO
    • Connections - Terminals : power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end || power circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end || power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end
    • Coil Technology : built-in bidirectional peak limiting diode suppressor
    • Maximum Operating Rate : 3600 cyc/h at 60 °C
    • Inrush Power In W : 2.4-2.4 W 20 °C)
    • Auxiliary Contacts Type : mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
    • Overvoltage Category : III
    • Maximum Horse Power Rating : 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 2 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 2 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 5 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 7.5 hp at 575/600 V AC 50/60 Hz for 3 phase motors || 0.33 hp at 115 V AC 50/60 Hz for 1 phase motors
    • Motor Power Kw : 2.2 kW at 220...230 V AC 50/60 Hz (AC-3) || 4 kW at 380...400 V AC 50/60 Hz (AC-3) || 4 kW at 415...440 V AC 50/60 Hz (AC-3) || 5.5 kW at 500 V AC 50/60 Hz (AC-3) || 5.5 kW at 660...690 V AC 50/60 Hz (AC-3) || 2.2 kW at 400 V AC 50/60 Hz (AC-4) || 2.2 kW at 220...230 V AC 50/60 Hz (AC-3e) || 4 kW at 380...400 V AC 50/60 Hz (AC-3e) || 4 kW at 415...440 V AC 50/60 Hz (AC-3e) || 5.5 kW at 500 V AC 50/60 Hz (AC-3e) || 5.5 kW at 660...690 V AC 50/60 Hz (AC-3e)
    • [Ui] Rated Insulation Voltage : power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL
    • Protective Cover : with
    • [Ith] Conventional Free Air Thermal Current : 25 A (at 60 °C) for power circuit || 10 A (at 60 °C) for signalling circuit
    • Control Circuit Voltage Limits : 0.1...0.3 Uc (-40-70 °C):drop-out DC || 0.8...1.25 Uc (-40-60 °C):operational DC || 1...1.25 Uc (60-70 °C):operational DC
    • Control Circuit Type : DC low consumption
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Pollution Degree : 3
    • Rated Breaking Capacity : 250 A at 440 V for power circuit conforming to IEC 60947
    • Irms Rated Making Capacity : 250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1
    • Associated Fuse Rating : 10 A gG for signalling circuit conforming to IEC 60947-5-1 || 25 A gG at <= 690 V coordination type 1 for power circuit || 20 A gG at <= 690 V coordination type 2 for power circuit
    • Time Constant : 40 ms
    • Operating Time : 77 ±15 % ms closing || 25 ±20 % ms opening
    • Minimum Switching Voltage : 17 V for signalling circuit
    • Signalling Circuit Frequency : 25...400 Hz
    • Tightening Torque : power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals pozidriv No 2 || power circuit 1.7 N.m screw clamp terminals pozidriv No 2
    • Electrical Durability : 0.6 Mcycles 25 A AC-1 <= 440 V || 2 Mcycles 9 A AC-3 <= 440 V || 2 Mcycles 9 A AC-3e <= 440 V
    • Mechanical Durability : 30 Mcycles
    • Compatibility Code : LC1D
    • [Icw] Rated Short-Time Withstand Current : 105 A 40 °C - 10 s for power circuit || 210 A 40 °C - 1 s for power circuit || 30 A 40 °C - 10 min for power circuit || 61 A 40 °C - 1 min for power circuit || 100 A - 1 s for signalling circuit || 120 A - 500 ms for signalling circuit || 140 A - 100 ms for signalling circuit
  • Specifications
    • Country of Origin : Indonesia
    • Width : 45 mm
    • Height : 77 mm
    • Weight : 0.48 kg
    • [Uc] Control Circuit Voltage : 48 V DC
    • [Ue] Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
    • Contactor Application : motor control || resistive load
    • Product Or Component Type : contactor
    • Utilisation Category : AC-1 || AC-4 || AC-3 || AC-3e
    • [Ie] Rated Operational Current : 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit || 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    • Poles Description : 3P
    • Range Of Product : TeSys Deca
    • Device Short Name : LC1D