TeSys Deca contactor - 3P(3 NO) - AC-3/AC-3e - <= 440 V 25 A - 200 V AC coil

TeSys Deca contactor - 3P(3 NO

SQDLC1D25L7 LC1D25L7 3389110349757
208.31 / EA
http://schema.org/OutOfStock
  • Depth: 92 mm
  • Warranty Length: 18 mth
TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 25A/690V AC-3/3e (11kW@400V). It provides a 200V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 25A/690V AC-3/3e (11kW@400V). It provides a 200V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Product Certifications : UL, CCC, CSA, Marine, UKCA, EAC, CB Scheme
    • Standards : CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 60947-4-1, IEC 60335-1:Clause 30.2, IEC 60335-2-40:Annex JJ, UL 60335-2-40:Annex JJ, CSA C22.2 No 60947-4-1
  • Complementary Attributes
    • Control Circuit Voltage Limits : 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz, 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz, 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz
    • Irms Rated Making Capacity : 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 450 A at 440 V for power circuit conforming to IEC 60947
    • Maximum Horse Power Rating : 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 2 hp at 115 V AC 50/60 Hz for 1 phase motors, 7.5 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 15 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 20 hp at 575/600 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 200/208 V AC 50/60 Hz for 3 phase motors
    • Icw Rated Short Time Withstand Current : 240 A 40 °C - 10 s for power circuit, 380 A 40 °C - 1 s for power circuit, 50 A 40 °C - 10 min for power circuit, 120 A 40 °C - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
    • Ie Rated Operational Current : 25 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    • Uc Control Circuit Voltage : 200 V, 200 V AC 50/60 Hz
    • Ue Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz, power circuit <= 300 V DC
    • Ui Rated Insulation Voltage : signalling circuit 600 V CSA, signalling circuit 600 V UL, power circuit 690 V IEC 60947-4-1, power circuit 600 V CSA, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1
    • Control Circuit Type : AC 50/60 Hz
    • Maximum Motor Phase Current : 25 A
    • Maximum Operating Rate : 3600 cyc/h at 60 °C
    • Minimum Switching Current : 5 mA for signalling circuit
    • Minimum Switching Voltage : 17 V for signalling circuit
    • Rated Breaking Capacity : 450 A at 440 V for power circuit conforming to IEC 60947
    • Uimp Rated Impulse Withstand Voltage : 6 kV IEC 60947
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Associated Fuse Rating : 10 A gG for signalling circuit conforming to IEC 60947-5-1, 63 A gG at <= 690 V coordination type 1 for power circuit, 40 A gG at <= 690 V coordination type 2 for power circuit
    • Contactor Application : motor control, resistive load
    • Electrical Durability : 1.65 Mcycles 25 A AC-3 <= 440 V, 1.4 Mcycles 40 A AC-1 <= 440 V, 1.65 Mcycles 25 A AC-3e <= 440 V
    • Hold In Power Consumption In Va : 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C), 7-7 VA 50 Hz cos phi 0.3 (at 20 °C)
    • Inrush Power In Va : 70-70 VA 60 Hz cos phi 0.75 (at 20 °C), 70-70 VA 50 Hz cos phi 0.75 (at 20 °C)
    • Insulation Resistance : > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
    • Mechanical Robustness : vibrations contactor open 2 Gn, 5...300 Hz), vibrations contactor closed 4 Gn, 5...300 Hz), shocks contactor closed 15 Gn for 11 ms), shocks contactor open 8 Gn for 11 ms)
    • Motor Power Kw : 11 kW at 380...400 V AC 50/60 Hz (AC-3e), 11 kW at 415...440 V AC 50/60 Hz (AC-3e), 15 kW at 500 V AC 50/60 Hz (AC-3e), 15 kW at 660...690 V AC 50/60 Hz (AC-3e), 5.5 kW at 220...230 V AC 50/60 Hz (AC-3), 11 kW at 380...400 V AC 50/60 Hz (AC-3), 11 kW at 415...440 V AC 50/60 Hz (AC-3), 15 kW at 500 V AC 50/60 Hz (AC-3), 15 kW at 660...690 V AC 50/60 Hz (AC-3), 5.5 kW at 400 V AC 50/60 Hz (AC-4), 5.5 kW at 220...230 V AC 50/60 Hz (AC-3e)
    • Mounting Support : rail, plate
    • Non Overlap Time : 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
    • Operating Time : 12...22 ms closing, 4...19 ms opening
    • Power Dissipation Per Pole : 3.2 W AC-1, 1.25 W AC-3, 1.25 W AC-3e
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Tightening Torque : power circuit 2.5 N.m screw clamp terminals Philips No 2, power circuit 2.5 N.m screw clamp terminals pozidriv No 2, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals Philips No 2, power circuit 2.5 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals pozidriv No 2
    • Utilisation Category : AC-4, AC-1, AC-3, AC-3e
    • Connections Terminals : control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 1-10 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 1.5-10 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: solid without cable end, screw clamp terminals, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 1 2.5-10 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 1.5-6 mm² - cable stiffness: flexible with cable end
    • Icw Rated Short Time Withstand Current : 240 A 40 °C - 10 s for power circuit, 380 A 40 °C - 1 s for power circuit, 50 A 40 °C - 10 min for power circuit, 120 A 40 °C - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
    • Ie Rated Operational Current : 25 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    • Ith Conventional Free Air Thermal Current : 10 A (at 60 °C) for signalling circuit, 40 A (at 60 °C) for power circuit
    • Carbon Footprint Of The Distribution Phase A4 : 0.1717166017648144, 0.2 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.8986268399705376, 0.9 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 2 kg CO2 eq., 2.274446711691528
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 123 kg CO2 eq., 123.4211523629405
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-08
    • Global Commercial Status : Commercialised
    • Return Indicator : Y
    • Stocking Flag : Y
    • Stock Policy : 1
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Legacy Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI110229EN
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Conformity Date : 0627
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : No
    • China Rohs Label : 1
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Average Impedance : 2 mOhm - Ith 40 A 50 Hz for power circuit
    • Coil Technology : without built-in suppressor module
    • Compatibility Code : LC1D
    • Contact Compatibility : M2
    • Device Short Name : LC1D
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Flame Retardance : V1 conforming to UL 94
    • Heat Dissipation : 2-3 W at 50/60 Hz
    • Mechanical Durability : 15 Mcycles
    • Overvoltage Category : III
    • Pole Contact Composition : 3 NO
    • Poles Description : 3P
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Protective Treatment : THIEC 60068-2-30
    • Range Of Product : TeSys Deca
    • Returnability : Yes
    • Signalling Circuit Frequency : 25...400 Hz
    • Software Version : v6.1
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 127 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Warranty In Months : 18
    • Control Circuit Voltage : 200 V
    • Inf Motor Phase Current : 25 A
    • Pep Code : ENVPEP110229EN
    • Database Version : 2023-02
    • Pep Verification Date : 2025-08-05
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Product Weight In G2 : 370
    • Reference Lifetime In Y2 : 20
    • Energy Consumption On Product Lifetime In Kwh : 301.125
    • Energy Model Manufacturing A1 A3 2 : France, FR
    • Energy Model Installation A5 2 : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Energy Model End Of Life C1 C4 2 : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Recyclability Potential In 2 : 66
    • Offer Owner Code : 190788
    • Height Nominal : 85 mm
    • Width Nominal : 45 mm
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Climatic Withstand : IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
    • Permissible Ambient Air Temperature Around The Device : -40-60 °C, -40-60 °C, 60-70 °C with derating
    • Take Back : Nej
    • Reach Free Shvc : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • Carbon Footprint : 126.76594251636737
    • Circularity Profile : ENVEOLI110229EN
    • Environmental Disclosure : ENVPEP110229EN
    • Eu Rohs Directive : Compliant
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP110229EN
    • Pep Verification Date : 2025-08-05
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca
  • ETIM
    • ETIM 8 : EC000066
    • ETIM 9 : EC000066
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Depth : 92 mm