TeSys Deca , star delta starter , 3 x 3P (3 NO) , 32 A , 120 V coil

WYE-DELTA STARTER 575VAC 30KW

SQDLC3D320AG7 LC3D320AG7 3389110508604
4056.94 / EA
http://schema.org/OutOfStock
  • Depth: 149 mm
  • Warranty Length: 18 mth
TeSys Deca pre-assembled star-delta starter, for motor control applications up to 11kW@400V in delta connection. Plate mounted starter, open version, composed of 3 contactors LC1D with 24V 50/60Hz AC coils, 1NC built-in auxiliary contact on star, a time-delay contact block 1-30 sec. For operating rates until 30 starts/hour, maximum starting time 30 sec. Compact assembly (144mm width), screw fixing. Equipped with pre-wired star delta power connections, and mechanical interlock, the use of a thermal overload relay (to be ordered separately) is strongly recommended.
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca pre-assembled star-delta starter, for motor control applications up to 11kW@400V in delta connection. Plate mounted starter, open version, composed of 3 contactors LC1D with 24V 50/60Hz AC coils, 1NC built-in auxiliary contact on star, a time-delay contact block 1-30 sec. For operating rates until 30 starts/hour, maximum starting time 30 sec. Compact assembly (144mm width), screw fixing. Equipped with pre-wired star delta power connections, and mechanical interlock, the use of a thermal overload relay (to be ordered separately) is strongly recommended.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Product Certifications : UL, GOST, LROS (Lloyds register of shipping), RINA, DNV, CSA, CCC, BV, GL
    • Standards : IEC 60947-5-1, UL 508, EN 60947-4-1, CSA C22.2 No 14, EN 60947-5-1, IEC 60947-4-1, IEC 60335-1
  • Complementary Attributes
    • Control Circuit Voltage Limits : drop-out: 0.3...0.6 Uc at 50/60 Hz (at <60 °C), operational: 0.8...1.1 Uc at 50 Hz (at <60 °C), operational: 0.85...1.1 Uc at 60 Hz (at <60 °C)
    • Ui Rated Insulation Voltage : signalling circuit 600 V UL, power circuit 600 V CSA, power circuit 600 V UL, signalling circuit 600 V CSA, power circuit 1000 V IEC 60947-4-1, signalling circuit 1000 V IEC 60947-1
    • Control Circuit Type : AC 50/60 Hz
    • Maximum Operating Rate : 30 cyc/h 60 °C
    • Minimum Switching Current : 5 mA for signalling circuit
    • Ie Rated Operational Current : 32 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
    • Uc Control Circuit Voltage : 120 V 50/60 Hz
    • Ue Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz
    • Uimp Rated Impulse Withstand Voltage : 8 kV IEC 60947
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Hold In Power Consumption In Va : 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C), 7-7 VA 50 Hz cos phi 0.3 (at 20 °C)
    • Inrush Power In Va : 70-70 VA 60 Hz cos phi 0.75 (at 20 °C), 70-70 VA 50 Hz cos phi 0.75 (at 20 °C)
    • Insulation Resistance : > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
    • Mechanical Robustness : vibrations contactor open2 Gn, 5...300 Hz, vibrations contactor closed4 Gn, 5...300 Hz, shocks contactor closed15 Gn for 11 ms, shocks contactor open8 Gn for 11 ms
    • Motor Power Kw : 15 kW 220/230 V AC 50/60 Hz, 25 kW 380/400 V AC 50/60 Hz, 30 kW 415 V AC 50/60 Hz, 30 kW 440 V AC 50/60 Hz
    • Non Overlap Time : 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
    • Range : TeSys, TeSys Deca
    • Tightening Torque : power circuit 2.5 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals pozidriv No 2, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals Philips No 2, power circuit 2.5 N.m screw clamp terminals flat Ø 6 mm, power circuit 1.7 N.m screw clamp terminals pozidriv No 2
    • Connections Terminals : control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 1-10 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 1.5-10 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 1 2.5-10 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 1.5-6 mm² - cable stiffness: flexible with cable end
    • Carbon Footprint Of The Distribution Phase A4 : 0.9421208150880356, 0.9 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 5 kg CO2 eq., 4.930304013892409
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 12 kg CO2 eq., 12.478721147929194
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 431 kg CO2 eq., 430.85202279426505
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-02-26
    • Global Commercial Status : Commercialised
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Legacy Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI110229EN
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Conformity Date : 1905
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : No
    • China Rohs Label : 1
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Coil Technology : without built-in suppressor module
    • Contactor Application : motor control
    • Device Short Name : LC3D
    • Electrical Durability : 1.65 Mcycles 32 A AC-3 <= 440 V
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Flame Retardance : V1 conforming to UL 94
    • Heat Dissipation : 2-3 W 50/60 Hz
    • Interlocking Type : mechanical
    • Mechanical Durability : 15 Mcycles
    • Mounting Support : rail
    • Overvoltage Category : III
    • Pole Contact Composition : 3 x 3 NO
    • Poles Description : 3 x 3P
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Name : TeSys Deca
    • Product Or Component Type : star delta starter
    • Protective Treatment : TH IEC 60068-2-30
    • Provided Equipment : protective cover
    • Range Of Product : TeSys Deca
    • Returnability : No
    • Signalling Circuit Frequency : 25...400 Hz
    • Software Version : v6.1
    • Starting Time : 30 s
    • Sustainable Packaging : Yes
    • Switching Voltage : 17 V signalling circuit
    • Total Lifecycle Carbon Footprint : 449 kg CO2 eq.
    • Utilisation Category : AC-3
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Ie Rated Operational Current : 32 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
    • Warranty In Months : 18
    • Control Circuit Voltage 18 Control Circuit Voltage : 120 V
    • Rated Operational Current 3 : 32 A
    • Pep Code : ENVPEP110229EN
    • Database Version : 2023-02
    • Pep Verification Date : 2025-08-05
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Product Weight In G2 : 2030
    • Reference Lifetime In Y2 : 20
    • Energy Consumption On Product Lifetime In Kwh : 1051.2
    • Energy Model Manufacturing A1 A3 2 : France, FR
    • Energy Model Installation A5 2 : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Energy Model End Of Life C1 C4 2 : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Recyclability Potential In 2 : 66
    • Offer Owner Code : 190788
    • Height Nominal : 124 mm
    • Width Nominal : 166 mm
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Ambient Air Temperature For Operation : -40-70 °C at Uc, -40-70 °C at Uc, -40-70 °C at Uc, -40-70 °C at Uc
    • Climatic Withstand : IACS E10, IEC 60947-1 Annex Q category D
    • Take Back : Nej
    • Reach Free Shvc : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 449.20316877117466
    • Ambient Air Temperature For Storage : -60-80 °C
    • Circularity Profile : ENVEOLI110229EN
    • Environmental Disclosure : ENVPEP110229EN
    • Eu Rohs Directive : Compliant
    • Ip Degree Of Protection : IP2X front face IEC 60529
    • Operating Altitude : 9842.52 ft (3000 m) without derating
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP110229EN
    • Pep Verification Date : 2025-08-05
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : star delta starter
    • Provided Equipment : protective cover
    • Range Of Product : TeSys Deca
  • ETIM
    • ETIM 8 : EC000010
    • ETIM 9 : EC000010
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Depth : 149 mm
  • Overview Attributes
    • Device Presentation : pre-wired