IEC contactor, TeSys Deca Advanced, nonreversing, 25A, 15HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 100/250VAC/VDC coil

CONTACTOR 600VAC 25AMP IEC +OP

SQDLC1D25KUE LC1D25KUE 3606480987748
247.84 / EA
http://schema.org/OutOfStock
  • Country of Origin: France
  • Depth: 3.62 in
  • Height: 3.35 in
  • Warranty Length: 18 mth
  • Width: 1.77 in
TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 25A/690V AC-3/3e (11kW@400V). They can be used to create motor starters for almost any type of application. It provides a low sealed consumption 100-250V AC/DC coil with electronic
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 25A/690V AC-3/3e (11kW@400V). They can be used to create motor starters for almost any type of application. It provides a low sealed consumption 100-250V AC/DC coil with electronic
  • Uc Control Circuit Voltage
    • 100...250 V AC 50/60 Hz
    • 100...250 V DC
  • Insulation Resistance
    • > 10 MOhm for signalling circuit
  • Heat Dissipation
    • 1.1-1.1 W at 50/60 Hz
  • Connections Terminals
    • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end
    • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffne
  • Mounting Support
    • plate
    • rail
  • Uimp Rated Impulse Withstand Voltage
    • 6 kV IEC 60947
  • Climatic Withstand
    • IACS E10 exposure to damp heat
    • IEC 60947-1 Annex Q category D exposure to damp heat
  • Power Dissipation Per Pole
    • 3.2 W AC-1
    • 1.25 W AC-3
    • 1.25 W AC-3e
  • Maximum Operating Rate
    • 3600 cyc/h at 60 °C
  • Carbon Footprint Of The Installation Phase A5
    • 0 kg CO2 eq.
    • 0.047993159540356975
  • Non Overlap Time
    • 1.5 ms on de-energisation between NC and NO contact
    • 1.5 ms on energisation between NC and NO contact
  • Carbon Footprint Of The End Of Life Phase C1 To C4
    • 0.7375323754339642
    • 0.7 kg CO2 eq.
  • Standards
    • EN/IEC 60947-4-1
    • EN/IEC 60947-5-1
    • UL 60947-4-1
    • CSA C22.2 No 60947-4-1
    • IEC 60335-1
  • Ue Rated Operational Voltage
    • power circuit <= 690 V AC 25...400 Hz
  • Ui Rated Insulation Voltage
    • power circuit 690 V IEC 60947-4-1
    • signalling circuit 690 V IEC 60947-1
  • Operating Time
    • 45...55 ms closing
    • 20...90 ms opening
  • Control Circuit Type
    • AC/DC 50/60 Hz AC/DC electronic
  • Ip Degree Of Protection
    • IP20 front face IEC 60529
  • Minimum Switching Voltage
    • 17 V for signalling circuit
  • Carbon Footprint Of The Manufacturing Phase A1 To A3
    • 4 kg CO2 eq.
    • 3.5608747952923987
  • Average Impedance
    • 2 mOhm - Ith 40 A 50 Hz for power circuit
  • Accessories
    • LAD9V2
    • LAD9R1V
    • LAD9R1
  • Electrical Durability
    • 2 Mcycles 21 A AC-3 <= 440 V
    • 0.9 Mcycles 40 A AC-1 <= 440 V
    • 2 Mcycles 21 A
  • Maximum Horse Power Rating
    • 2 hp at 115 V AC 60 Hz for 1 phase motors
    • 3 hp at 230/240 V AC 60 Hz for 1 phase motor
  • Market Segmentation
    • Commercial
    • Industrial
  • Persona Type Names
    • End User
    • Contractor
    • Original Equipment Manufacturer
    • OEM - Control Panelbuilder
    • Panel Builder
    • System Integrator
  • Inrush Power In W
    • 18-18 W 20 °C)
  • Fire Resistance
    • 850 °C IEC 60695-2-1
  • Contactor Application
    • motor control
    • resistive load
  • Flame Retardance
    • V1 conforming to UL 94
  • Carbon Footprint Of The Use Phase B2 B3 B4 B6
    • 12 kg CO2 eq.
    • 11.925165789473688
  • Persona Type Ids
    • EU
    • LC
    • OM
    • OM8
    • PB
    • SI
  • Auxiliaries
    • LADN22
    • LADN11
    • LADN20
    • LAD8N11
    • LADT2
    • LADN40
    • LAD6K10M
  • Safety Reliability Level
    • B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
    • B10d = 1369863 cycles contactor with nominal load EN/ISO 13
  • Carbon Footprint Of The Distribution Phase A4
    • 0.12856654969324607
    • 0.1 kg CO2 eq.
  • Tightening Torque
    • control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm
    • control circuit 1.7 N.
  • Ith Conventional Free Air Thermal Current
    • 10 A (at 60 °C) for signalling circuit
    • 40 A (at 60 °C) for power circuit
  • Irms Rated Making Capacity
    • 140 A AC for signalling circuit conforming to IEC 60947-5-1
    • 250 A DC for s
  • Mechanical Robustness
    • vibrations contactor open 2 Gn, 5...300 Hz)
    • vibrations contactor closed 4 Gn, 5...300 Hz)
    • vibrations contactor closed 4
  • Minimum Switching Current
    • 5 mA for signalling circuit
  • Motor Power Kw
    • 5.5 kW at 220...230 V AC 50 Hz (AC-3)
    • 11 kW at 380...400 V AC 50 Hz (AC-3)
    • 11 kW at 380...400 V AC 50
  • Control Circuit Voltage Limits
    • <= 0.1 Uc (-40-70 °C):drop-out AC/DC
    • 0.85...1.1 Uc (-40-60 °C):operational AC/DC
    • 0.85...1.1 Uc (-40
  • Utilisation Category
    • AC-3
    • AC-1
    • AC-3e
  • Hold In Power Consumption In W
    • 1.1-1.1 W 20 °C
  • Ie Rated Operational Current
    • 25 A (at <60 °C) at <= 440 V AC-3 for power circuit
    • 25 A (at <60 °C) at <= 440 V AC-3 for power ci
  • Icw Rated Short Time Withstand Current
    • 100 A - 1 s for signalling circuit
    • 120 A - 500 ms for signalling circuit
    • 140 A - 100 ms for signalling circu
  • Hold In Power Consumption In Va
    • 1.6-1.6 VA 50/60 Hz (at 20 °C)
  • Market Segmentation Id
    • COMMERCIAL
    • INDUSTRIAL
  • Inrush Power In Va
    • 25-25 VA 50/60 Hz (at 20 °C)
  • Associated Fuse Rating
    • 10 A gG for signalling circuit conforming to IEC 60947-5-1
    • 63 A gG at <= 690
  • Permissible Ambient Air Temperature Around The Device
    • -40-60 °C
    • 60-70 °C with derating
  • Rated Breaking Capacity
    • 450 A at 440 V for power circuit conforming to IEC 60947
  • Product Certifications
    • CCC
    • CSA
    • EAC
    • UL
    • KC
    • DNV-GL
    • LROS (Lloyds register of shipping)
    • UKCA
  • Important Information Attributes
    • Country Id : US
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-01
    • ETIM 10 : EC000066
    • Html Descr : TeSys D contactor 3P 25A AC-3 up to 440V coil 100, 250V AC/DC
    • Manufacturer : Schneider Electric
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Manufacturing Carbon Footprint : 3.5608747952924
    • Distribution Carbon Footprint : 0.128566549693246
    • Installation Carbon Footprint : 4.7993159540357e-02
    • Use Carbon Footprint : 11.9251657894737
    • End Of Life Carbon Footprint : 0.737532375433964
    • Legacy WEEE Scope : In
    • WEEE Product Category : 5
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1609001EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS Eur In Scope : Yes
    • ROHS Eur Status : Compliant with Exemptions
    • ROHS Eur Conformity Date : 1922
    • ROHS Eur Full Compliance Status : Compliant with Exemptions
    • ROHS Eur Full Compliance Status Id : COMPLIANT_WITH_EXEMPTIONS
    • China ROHS In Scope : No
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Coil Technology : built-in bidirectional peak limiting
    • Compatibility Code : LC1D
    • Device Short Name : LC1D
    • Halogen Free Status : Halogen free plastic parts and cables product
    • Mechanical Durability : 15 Mcycles
    • Overvoltage Category : III
    • Package Weight Lbs : 454.000 g
    • Pole Contact Composition : 3 NO
    • Poles Description : 3P
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca Advanced
    • Returnability : Yes
    • Signalling Circuit Frequency : 25...400 Hz
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 16 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Carbon Footprint Kg Co2 Eq Total Life Cycle : 16.400132669433653
    • Relationshiptype : Compatible relationship
  • General Attributes
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca Advanced
  • Environment Attributes
    • ROHS Exemption Information : Yes
    • China ROHS Url : https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=exportPdfRoHSChina&pid=433143086&lang=en-us
    • Take Back : No
    • Halogene Performance : Halogen free plastic parts & cables product
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Mercury Free : Yes
    • Carbon Footprint : 16.4001326694337
    • Circularity Profile : ENVEOLI1609001EN
    • Environmental Disclosure : ENVPEP1609001EN
    • Eu Rohs Directive : Compliant with Exemptions
    • Halogen Content Performance : Halogen free plastic parts & cables product
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : France
    • Height : 3.35 in
    • Width : 1.77 in
    • Depth : 3.62 in