Reversing power base, TeSys Ultra, 3P, 12A/690V, coil 110-240VAC/DC

12A SELF-PR.REV.STR W/TERMS- L

SQDLU2B12FU LU2B12FU 3389110362961
735.67 / EA
http://schema.org/OutOfStock
  • Depth: 126 mm
  • Warranty Length: 18 mth
TeSys U standard reversing power base, 3 poles (3NO), rated 12A/690V, to be completed with a control unit LUC to form a TeSys U reversing starter controller, for 3-phase motor applications up to 5.5kW@400V. Base composed of power contacts, control coil, rotary handle, with a modular design for additional modules to form a "all in one" reversing starter controller with basic or advanced protection and control functions. It is equipped with a reverser module LU2MB0FU to be supplied with 110-240V AC / 110-220V DC, auxiliary signaling contacts (1NO+1NC), a control terminal block, blanking shutters covering the empty cavities. It provides a high breaking capacity Icu 50kA@400V, start-stop control guaranteed for 3600 cycles/hour. Very compact (45mm width), DIN-rail mounting and screw fixing, with a padlockable rotary handle. Certified when used in conjunction with a LUC control unit (IEC, UL, CSA, CCC, EAC, Marine).
QTY
  • Product Description
  • Features
  • Specifications
TeSys U standard reversing power base, 3 poles (3NO), rated 12A/690V, to be completed with a control unit LUC to form a TeSys U reversing starter controller, for 3-phase motor applications up to 5.5kW@400V. Base composed of power contacts, control coil, rotary handle, with a modular design for additional modules to form a "all in one" reversing starter controller with basic or advanced protection and control functions. It is equipped with a reverser module LU2MB0FU to be supplied with 110-240V AC / 110-220V DC, auxiliary signaling contacts (1NO+1NC), a control terminal block, blanking shutters covering the empty cavities. It provides a high breaking capacity Icu 50kA@400V, start-stop control guaranteed for 3600 cycles/hour. Very compact (45mm width), DIN-rail mounting and screw fixing, with a padlockable rotary handle. Certified when used in conjunction with a LUC control unit (IEC, UL, CSA, CCC, EAC, Marine).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Product Certifications : CE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine
    • Standards : EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, with phase barrier, CSA C22.2 No 60947-4-1, with phase barrier
  • Complementary Attributes
    • Control Circuit Voltage Limits : 55 V DC drop-out, 55 V AC drop-out, 88...242 V DC in operation, 88...264 V AC in operation
    • Ics Rated Service Breaking Capacity : 50 kA 230 V, 50 kA 440 V, 10 kA 500 V, 4 kA 690 V
    • Ie Rated Operational Current : 12 A <= 440 V, 12 A 500 V, 9 A 690 V
    • Uc Control Circuit Voltage : 110...240 V AC 50/60 Hz, 110...220 V DC
    • Ui Rated Insulation Voltage : 690 V IEC 60947-6-2 3), 600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1
    • Maximum Operating Rate : 3600 cyc/h
    • Ue Rated Operational Voltage : 690 V AC power circuit
    • Uimp Rated Impulse Withstand Voltage : 6 kVIEC 60947-6-2
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Device Application : motor control, motor protection
    • Fire Resistance : 960 °C parts supporting live components IEC 60695-2-12, 650 °C IEC 60695-2-12
    • Fixing Mode : clipped (DIN rail), screw-fixed (plate)
    • Heat Dissipation : 2-2 W control circuit with LUCA, LUCB, LUCC, LUCD, 1.7-1.7 W control circuit with LUCM
    • Inrush Restraint Duration : 25 ms AC 50/60 Hz, 15 ms DC
    • Non Dissipating Shock Wave : 1 kV serial mode IEC 60947-6-2, 2 kV common mode IEC 60947-6-2
    • Operating Time : 150 ms with change of direction power circuit, 35 ms opening control circuit, 75 ms without change of direction power circuit, 50 ms closing control circuit
    • Resistance To Electrostatic Discharge : 8 kV 3 in open air IEC 61000-4-2, 8 kV 4 on contact IEC 61000-4-2
    • Resistance To Fast Transients : 2 kV 3 serial link IEC 61000-4-4, 4 kV 4 all circuits except for serial link IEC 61000-4-4
    • Safe Separation Of Circuit : 400 V SELV between the control and auxiliary circuits IEC 60947-1 appendix N, 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 appendix N
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Shock Resistance : 10 gn power poles open IEC 60068-2-27, 15 gn power poles closed IEC 60068-2-27
    • Tightening Torque : control circuit: 0.8-1.2 N.m flat screwdriver 5 mm, control circuit: 0.8-1.2 N.m Philips no 1 screwdriver 5 mm, power circuit: 1.9-2.5 N.m flat screwdriver 6 mm, power circuit: 1.9-2.5 N.m Philips No 2 screwdriver 6 mm, power circuit: 1.9-2.5 N.m pozidriv No 2 screwdriver 6 mm
    • Typical Current Consumption : 1000 mA 110...220 V DC I maximum while closing, 1000 mA 110...240 V AC I maximum while closing
    • Utilisation Category : AC-43, AC-44, AC-41
    • Vibration Resistance : 2 gn 5-300 Hz) power poles open IEC 60068-2-27, 4 gn 5-300 Hz) power poles closed IEC 60068-2-27
    • Connections Terminals : control circuit: screw clamp terminals 2 cable(s) 0.75-1.5 mm² flexible without cable end, control circuit: screw clamp terminals 2 cable(s) 0.75-1.5 mm² rigid, power circuit: screw clamp terminals 1 cable(s) 1-6 mm² flexible with cable end, power circuit: screw clamp terminals 2 cable(s) 1-6 mm² flexible with cable end, power circuit: screw clamp terminals 2 cable(s) 1-6 mm² rigid, control circuit: screw clamp terminals 1 cable(s) 0.34-1.5 mm² flexible with cable end, control circuit: screw clamp terminals 1 cable(s) 0.75-1.5 mm² flexible without cable end, control circuit: screw clamp terminals 1 cable(s) 0.75-1.5 mm² rigid, control circuit: screw clamp terminals 2 cable(s) 0.34-1.5 mm² flexible with cable end, power circuit: screw clamp terminals 1 cable(s) 1-10 mm² rigid, power circuit: screw clamp terminals 1 cable(s) 2.5-10 mm² flexible without cable end, power circuit: screw clamp terminals 2 cable(s) 1.5-6 mm² flexible without cable end
    • Ics Rated Service Breaking Capacity : 50 kA 230 V, 50 kA 440 V, 10 kA 500 V, 4 kA 690 V
    • Ie Rated Operational Current : 12 A <= 440 V, 12 A 500 V, 9 A 690 V
    • Carbon Footprint Of The Distribution Phase A4 : 0.6923836093771566, 0.7 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 3.2770793021610225, 3 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0.1 kg CO2 eq., 0.09043196322949147
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 9 kg CO2 eq., 8.800157255420025
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 15 kg CO2 eq., 14.924864966718355
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-02-26
    • Global Commercial Status : Commercialised
    • Return Indicator : Y
    • Stocking Flag : Y
    • Stock Policy : 1
    • Weee Applicability : Finished product
    • Weee Scope : In
    • Legacy Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2407003EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2023
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : No
    • China Rohs Label : 7
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 2
    • Tier : 2
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Compatibility Code : LU2B
    • Device Short Name : LU2B
    • Energy Efficiency Optimized : False
    • Halogen Free Status : Product contains halogen above thresholds
    • Immunity To Microbreaks : 3 ms control circuit
    • Immunity To Radioelectric Fields : 10 V IEC 61000-4-6
    • Immunity To Voltage Dips : 70 % / 500 ms IEC 61000-4-11
    • Mechanical Durability : 15 Mcycles
    • Network Frequency : 40...60 Hz
    • Poles Description : 3P
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Name : TeSys Ultra
    • Product Or Component Type : reversing power base
    • Protective Treatment : TH IEC 60068
    • Range : TeSys
    • Range Of Product : TeSys Ultra
    • Resistance To Radiated Fields : 10 V/m 3 IEC 61000-4-3
    • Returnability : Yes
    • Software Version : v6.1
    • Suitability For Isolation : yes
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 28 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Ith Conventional Free Air Thermal Current : 12 A
    • Warranty In Months : 18
    • Thermal Current : 12 A
    • Control Circuit Voltage 8 Control Circuit Voltage : 110...220 V
    • Control Circuit Voltage 8 Control Circuit Type : DC
    • Pep Code : ENVPEP2407003EN
    • Database Version : 2023-02
    • Pep Verification Date : 2024-07-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Product Weight In G2 : 1296
    • Reference Lifetime In Y2 : 20
    • Energy Consumption On Product Lifetime In Kwh : 223.38
    • Energy Model Manufacturing A1 A3 2 : France, FR
    • Energy Model Installation A5 2 : Electricity Mix; Low voltage; 2018; France, FR
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2018; France, FR
    • Energy Model End Of Life C1 C4 2 : Electricity Mix; Low voltage; 2018; France, FR
    • Recyclability Potential In 2 : 58
    • Offer Owner Code : 190788
    • Height Nominal : 224 mm
    • Width Nominal : 45 mm
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Ambient Air Temperature For Operation : -25-60 °C with LUCM, -25-60 °C with LUCM, -25-70 °C with LUCA, LUCB, LUCC, LUCD, -25-70 °C with LUCA, LUCB, LUCC, LUCD, -25-60 °C with LUCM, -25-60 °C with LUCM, -25-70 °C with LUCA, LUCB, LUCC, LUCD
    • Ip Degree Of Protection : IP20 IEC 60947-1 front panel and wired terminals), IP20 IEC 60947-1 other faces), IP40 IEC 60947-1 front panel outside connection zone)
    • Product Compatibility : control unit LUC.X6FU, control unit LUC.1XFU, control unit LUC.05FU, control unit LUC.12FU
    • Take Back : Nej
    • Halogene Performance : Product contains halogen above thresholds
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 27.784917096906053
    • Ambient Air Temperature For Storage : -40-85 °C
    • Circularity Profile : ENVEOLI2407003EN
    • Environmental Disclosure : ENVPEP2407003EN
    • Eu Rohs Directive : Compliant By Exemption
    • Halogen Content Performance : Product contains halogen above thresholds
    • Operating Altitude : 6561.68 ft (2000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2407003EN
    • Pep Verification Date : 2024-07-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : reversing power base
    • Range Of Product : TeSys Ultra
  • ETIM
    • ETIM 8 : EC001037
    • ETIM 9 : EC001037
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Depth : 126 mm