Reverser block for vertical mounting, TeSys Ultra, 38A/690V, coil 110-240VAC/DC

REV.BLK. DIRECT MNT.W/O TERMS

SQDLU2MB0FU LU2MB0FU 3389110363807
254.65 / EA
http://schema.org/OutOfStock
  • Country of Origin: France
  • Depth: 105 mm
  • Height: 80 mm
  • Net Weight: 0.4 kg
  • Warranty Length: 18 mth
  • Weight: 0.4 kg
  • Width: 45 mm
TeSys U reversing module for vertical mounting, for the constitution of TeSys U reversing starter controllers. It provides reverse power contacts, coil control with interlocking capabilities to be supplied with 110-240V AC / 110-220V DC. To be used with an advanced power base LUB120, LUB320, or LUB380 equipped with a Control Unit LUC*FU type. To be associated with an assembling connector LU9MR1C and a control terminal block LU9M1 to complete the vertical mounting.
QTY
  • Product Description
  • Features
  • Specifications
TeSys U reversing module for vertical mounting, for the constitution of TeSys U reversing starter controllers. It provides reverse power contacts, coil control with interlocking capabilities to be supplied with 110-240V AC / 110-220V DC. To be used with an advanced power base LUB120, LUB320, or LUB380 equipped with a Control Unit LUC*FU type. To be associated with an assembling connector LU9MR1C and a control terminal block LU9M1 to complete the vertical mounting.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Ambient Air Temperature For Operation : -25-60 °C with LUCM || -25-70 °C with LUCA, LUCB, LUCC, LUCD
    • Resistance To Radiated Fields : 10 V/m level 3 IEC 61000-4-3
    • Non-Dissipating Shock Wave : 1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2
    • Shock Resistance : 10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27
    • Vibration Resistance : 2 gn 5-300 Hz) power poles open IEC 60068-2-27 || 4 gn 5-300 Hz) power poles closed IEC 60068-2-27
    • Ambient Air Temperature For Storage : -40-85 °C
    • Protective Treatment : TH IEC 60068
    • Ip Degree Of Protection : IP20 IEC 60947-1 front panel and wired terminals) || IP20 IEC 60947-1 other faces) || IP40 IEC 60947-1 front panel outside connection zone)
    • Resistance To Electrostatic Discharge : 8 kV level 3, in open air IEC 61000-4-2 || 8 kV level 4, on contact IEC 61000-4-2
    • Operating Altitude : 6561.68 ft (2000 m)
    • Fire Resistance : 960 °C parts supporting live components IEC 60695-2-12 || 650 °C IEC 60695-2-12
    • Immunity To Radioelectric Fields : 10 V IEC 61000-4-6
    • Resistance To Fast Transients : 2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP2407003EN
    • Packaging Without Single Use Plastic : Yes
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Scip Number : ea04e023-7196-4d5e-a41f-a711a93b86d7
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Circularity Profile : ENVEOLI2407003EN
    • Take-Back : No
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 0
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 2.6889369391561186
    • Carbon Footprint Of The Distribution Phase [A4] : 0.2 kg CO2 eq.
    • Pvc Free : Yes
    • Carbon Footprint Of The Installation Phase [A5] : 0 kg CO2 eq.
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 4 kg CO2 eq.
    • Eu Rohs Directive : Compliant with Exemptions
    • Carbon Footprint Of The End-Of-Life Phase [C1 To C4] : 1.0013297867714235
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 3.9294603731129065
  • Complementary
    • Product Certifications : CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine
    • [Ue] Rated Operational Voltage : 690 V AC power circuit
    • Height : 80 mm
    • Connections - Terminals : control circuit screw clamp terminals 1 0.34-1.5 mm² 3 mm) flexible with cable end || control circuit screw clamp terminals 1 0.75-1.5 mm² 3 mm) flexible without cable end || control circuit screw clamp terminals 1 0.75-1.5 mm² 3 mm) rigid || control circuit screw clamp terminals 2 0.34-1.5 mm² 3 mm) flexible with cable end || control circuit screw clamp terminals 2 0.75-1.5 mm² 3 mm) flexible without cable end || control circuit screw clamp terminals 2 0.75-1.5 mm² 3 mm) rigid || power circuit screw clamp terminals 1 1-10 mm² 4 mm) rigid || power circuit screw clamp terminals 1 1-6 mm² 4 mm) flexible with cable end || power circuit screw clamp terminals 1 2.5-10 mm² 4 mm) flexible without cable end || power circuit screw clamp terminals 2 1-6 mm² 4 mm) flexible with cable end || power circuit screw clamp terminals 2 1-6 mm² 4 mm) rigid || power circuit screw clamp terminals 2 1.5-6 mm² 4 mm) flexible without cable end
    • Net Weight : 0.4 kg
    • Fixing Mode : plug-in
    • [Uimp] Rated Impulse Withstand Voltage : 6 kVIEC 60947-6-2
    • Inrush Restraint Duration : 25 ms AC || 15 ms DC
    • Standards : EN 60947-6-2 || IEC 60947-6-2 || UL 60947-4-1, with phase barrier || CSA C22.2 No 60947-4-1, with phase barrier
    • [Ui] Rated Insulation Voltage : 690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
    • Compatibility Code : LU2MB
    • Operating Time : 150 ms with change of direction || 75 ms without change of direction
    • Width : 45 mm
    • Tightening Torque : control circuit: 0.8-1.2 N.m flat screwdriver 5 mm || control circuit: 0.8-1.2 N.m Philips No 2 screwdriver 5 mm || power circuit: 1.9-2.5 N.m flat screwdriver 6 mm || power circuit: 1.9-2.5 N.m Philips No 2 screwdriver 6 mm
    • Depth : 105 mm
    • Network Frequency : 40...60 Hz
  • Specifications
    • Country of Origin : France
    • Width : 45 mm
    • Height : 80 mm
    • Weight : 0.4 kg
    • Device Mounting : direct mounting
    • [Uc] Control Circuit Voltage : 110...240 V AC 50/60 Hz || 110...220 V DC
    • Product Or Component Type : reverser block
    • Current Consumption : 1000 mA 110...220 V DC I maximum while closing || 1000 mA 110...240 V AC I maximum while closing
    • Range : TeSys
    • [Ie] Rated Operational Current : 38 A
    • Device Application : motor control
    • Device Short Name : LU2MB