SQUARE D

Contactor, high power, TeSys Giga, 3P(3NO), AC-3, <=440V 400A, standard version, 200-500V AC/DC wide band coil

Contactor, high power, TeSys G

SQDLC1G400LSEN LC1G400LSEN 3606486391952
3137.08 / EA
http://schema.org/OutOfStock
  • Country of Origin: Czechia
  • Depth: 226 mm
TeSys Giga high power contactor, 3 poles (3 NO) suitable for category AC-3 applications up to 400A 250kW@440V, equipped with 100-250V AC/DC wide band low consumption electronic coil and embedded highly reliable 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 500 cycles per hour and environments up to 60°C. It’s built with high reliability delivering mechanical durability up to 8 million cycles. Contact Wear Diagnosis (CWD) is a standard function, It continuously monitors and provide feedback through healthy and alarm conditions by an LED indicator. It is possible to replace switching module (main contacts), control module enhancing contactor life with simple maintenance activities. Front accessible main power connections are with bolted connection and control connections by push-in terminals for easy and quick assembly. It provides IP2x protection from front face with optional terminal shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, with no derating up to 3000m altitude. Contactor can be installed in three quadrants of vertical plane, and OLR could be directly mounted below contactor. The dimensions are 225mm x 140mm x 226mm (H x W x D), compact size enables panel space savings. Multi standards certified (CB, CCC, cULcs, CE, UKCA marking,CE). Unique QR code provides quick access to complete product data.
QTY
  • Product Description
  • Features
  • Specifications
TeSys Giga high power contactor, 3 poles (3 NO) suitable for category AC-3 applications up to 400A 250kW@440V, equipped with 100-250V AC/DC wide band low consumption electronic coil and embedded highly reliable 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 500 cycles per hour and environments up to 60°C. It’s built with high reliability delivering mechanical durability up to 8 million cycles. Contact Wear Diagnosis (CWD) is a standard function, It continuously monitors and provide feedback through healthy and alarm conditions by an LED indicator. It is possible to replace switching module (main contacts), control module enhancing contactor life with simple maintenance activities. Front accessible main power connections are with bolted connection and control connections by push-in terminals for easy and quick assembly. It provides IP2x protection from front face with optional terminal shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, with no derating up to 3000m altitude. Contactor can be installed in three quadrants of vertical plane, and OLR could be directly mounted below contactor. The dimensions are 225mm x 140mm x 226mm (H x W x D), compact size enables panel space savings. Multi standards certified (CB, CCC, cULcs, CE, UKCA marking,CE). Unique QR code provides quick access to complete product data.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Physical Attributes
    • Color : dark grey
  • Complementary Attributes
    • Maximum Operating Rate : 600 cyc/h AC-3, 600 cyc/h AC-3e300 cyc/h AC-1150 cyc/h AC-4
    • Uc Control Circuit Voltage : 200...500 V, 200...500 V AC 50/60 Hz, 200...500 V DC
    • Ue Rated Operational Voltage : <= 1000 V AC 50/60 Hz, <= 1000 V AC 50/60 Hz, <= 1000 V AC 50/60 Hz, <= 460 V DC, <= 460 V DC<= 1000 V AC 50/60 Hz, <= 1000 V AC 50/60 Hz, <= 1000 V AC 50/60 Hz, <= 460 V DC, <= 460 V DC
    • Control Circuit Voltage Limits : operational: 0.8 Uc Min...1.1 Uc Max (at <60 °C)drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C)
    • Irms Rated Making Capacity : 5090 A at 440 V
    • Maximum Horse Power Rating : 125 hp at 200/208 V 60 Hz150 hp at 230/240 V 60 Hz300 hp at 460/480 V 60 Hz400 hp at 575/600 V 60 Hz
    • Maximum Motor Phase Current : 400 A
    • Rated Breaking Capacity : 3480 A at 440 V
    • Icw Rated Short Time Withstand Current : 3.6 kA - 10 s2.4 kA - 30 s1.7 kA - 1 min1.2 kA - 3 min1.0 kA - 10 min
    • Ie Rated Operational Current : 550 A (at <40 °C) at <= 1000 V AC-1400 A (at <60 °C) at <= 440 V AC-3
    • Ui Rated Insulation Voltage : 1000 V
    • Uimp Rated Impulse Withstand Voltage : 8 kV
  • Important Information Attributes
    • Persona Type Ids : EU, OM, OM8, PB
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Associated Fuse Rating : 500 A aM at <= 440 V for motor315 A aM at <= 690 V for motor630 A gG at <= 690 V, 600 A UL Type L at <= 600 V
    • Contactor Application : power switching, motor control
    • Electrical Durability : 300 cycles AC-1 400 V500 cycles AC-3 400 V, 500 cycles AC-3e 400 V150 cycles AC-4 400 V
    • Mechanical Robustness : vibrations 5-300 Hz 2 gn contactor openvibrations 5-300 Hz 4 gn contactor closed, shocks 10 gn 11 ms contactor open, shocks 15 gn 11 ms contactor closed
    • Motor Power Kw : 200 kW at 400 V AC 50/60 Hz (AC-3), 200 kW at 415 V AC 50/60 Hz (AC-3), 250 kW at 440 V AC 50/60 Hz (AC-3), 250 kW at 500 V AC 50/60 Hz (AC-3), 315 kW at 690 V AC 50/60 Hz (AC-3), 220 kW at 1000 V AC 50/60 Hz (AC-3)200 kW at 400 V AC 50/60 Hz (AC-4), 200 kW at 415 V AC 50/60 Hz (AC-4), 220 kW at 440 V AC 50/60 Hz (AC-4), 250 kW at 500 V AC 50/60 Hz (AC-4), 315 kW at 690 V AC 50/60 Hz (AC-4), 220 kW at 1000 V AC 50/60 Hz (AC-4)110 kW at 230 V AC 50/60 Hz (AC-3e)200 kW at 400 V AC 50/60 Hz (AC-3e), 200 kW at 415 V AC 50/60 Hz (AC-3e)250 kW at 440 V AC 50/60 Hz (AC-3e), 250 kW at 500 V AC 50/60 Hz (AC-3e)315 kW at 690 V AC 50/60 Hz (AC-3e)220 kW at 1000 V AC 50/60 Hz (AC-3e), 110 kW at 230 V AC 50/60 Hz (AC-3), 110 kW at 230 V AC 50/60 Hz (AC-4)
    • Power Dissipation Per Pole : 30 W AC-1 - Ith 550 A, 16 W AC-3 - Ith 400 A
    • Utilisation Category : AC-1, AC-3, AC-3e, AC-4, AC-5a, AC-5b, AC-6a, AC-6b, AC-8a, AC-8b, DC-1, DC-3, DC-5
    • Connections Terminals : control circuit: push-in 0.75-2.5 mm² - cable stiffness: flexible with cable end, power circuit: bar 2 - busbar cross section: 32 x 10 mm, power circuit: lugs-ring terminals 1 185-185 mm², power circuit: bolted connection, control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end, control circuit: push-in 1 0.25-2.5 mm² - cable stiffness: flexible with cable end, control circuit: push-in 2 0.5-1.0 mm² with cable end, control circuit: push-in 0.75-2.5 mm² - cable stiffness: solid stranded without cable end
    • Certificate Agency : CB Scheme, CCC, cULus, EAC, CE, UKCA, EU-RO-MR by DNV-GL
    • Carbon Footprint Of The Distribution Phase A4 : 12.639908235885825, 13 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 11 kg CO2 eq., 11.103680846266759
    • Carbon Footprint Of The Installation Phase A5 : 0.10467794270991464, 0.1 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 70 kg CO2 eq., 69.73868162511891
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 1 303 kg CO2 eq., 1302.6407834784077
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-06-27
    • Return Indicator : Y
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2105013
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2121
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : No
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Average Impedance : 0.0001 Ohm
    • Coil Technology : built-in bidirectional peak limiting
    • Compatibility Code : LC1G
    • Connection Pitch : 45 mm
    • Device Short Name : LC1G
    • Inrush Power In Va : 535-535 VA
    • Inrush Power In W : 300 W
    • Mechanical Durability : 8 Mcycles
    • Mounting Support : plate
    • Number Of Poles : 3P
    • Operating Time : 40...70 ms closing15...50 ms opening
    • Overvoltage Category : III
    • Pole Contact Composition : 3 NO
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Protective Treatment : TH
    • Range : TeSys
    • Range Of Product : TeSys Giga
    • Returnability : Yes
    • Safety Reliability Level : B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Software Version : v6.2.4
    • Sustainable Packaging : Yes
    • Tightening Torque : 35 N.m
    • Total Lifecycle Carbon Footprint : 1 396 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Control Circuit Voltage : 200...500 V
    • Inf Motor Phase Current : 400 A
    • Rated Thermal Current Hv : 550 A
    • Database Version : 2024-01
    • Data Source : extrapolated product
    • Height Nominal : 225 mm
    • Width Nominal : 140 mm
    • Nbr. Of Units In Pkg. : 1
    • Ith Conventional Free Air Thermal Current : 550 A (at 40 °C)
    • Hold In Power Consumption In Va : 15.4-15.4 VA
    • Hold In Power Consumption In W : 8.6-8.6 W
    • Rated Thermal Current Ith : 550 A
    • Halogen Free Status : Halogen free plastic parts product
    • Warranty In Months : 18
    • Product Weight In G : 8214.8
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Reference Lifetime In Y : 20
    • Energy Consumption On Product Lifetime In Kwh : 1576.8
    • Recyclability Potential In % : 55
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Ambient Air Temperature For Operation : -25-60 °C, -25-60 °C
    • Ambient Air Temperature For Storage : -60-80 °C, -60-80 °C
    • Ip Degree Of Protection : IP2X front face with shrouds IEC 60529, IP2X front face with shrouds VDE 0106
    • Permissible Ambient Air Temperature Around The Device : -40-70 °C at Uc, -40-70 °C at Uc-40-70 °C at Uc, -40-70 °C at Uc
    • Take Back : No
    • Halogene Performance : Halogen free plastic parts product
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 1396.227732128389
    • Circularity Profile : ENVEOLI2105013
    • Environmental Disclosure : ENVPEP2105013EN
    • Eu Rohs Directive : Compliant By Exemption
    • Halogen Content Performance : Halogen free plastic parts product
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2105013EN
    • Pep Verification Date : 2026-03-19
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Giga
  • ETIM
    • ETIM 8 : EC000066
    • ETIM 9 : EC000066
  • Specifications
    • Country of Origin : Czechia
    • Depth : 226 mm