Changeover contactor, TeSys K, 4P, AC-1, lt or eq to 440V 10A, 24VDC coil

CHANGEOVER CONTACTOR, TESYS MI

SQDLP5K09004BW3 LP5K09004BW3 3389110501483
269.47 / EA
http://schema.org/OutOfStock
  • Warranty Length: 18 mth
TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1. It provides a 24V DC coil with integral suppression device, 1NO built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC).
QTY
  • Product Description
  • Features
  • Specifications
TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1. It provides a 24V DC coil with integral suppression device, 1NO built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Control Circuit Voltage Limits : operational: 0.7...1.30 Uc (at <50 °C), drop-out: 0.1...0.7 Uc (at <50 °C)
    • IRMS Rated Making Capacity : 110 A AC for power circuit conforming to NF C 63-110, 110 A AC for power circuit conforming to IEC 60947
    • Rated Breaking Capacity : 110 A at 415 V conforming to IEC 60947, 110 A at 440 V conforming to IEC 60947, 80 A at 500 V conforming to IEC 60947, 110 A at 220...230 V conforming to IEC 60947, 110 A at 380...400 V conforming to IEC 60947, 70 A at 660...690 V conforming to IEC 60947
    • ICW Rated Short Time Withstand Current : 90 A 50 °C - 1 s for power circuit, 85 A 50 °C - 5 s for power circuit, 80 A 50 °C - 10 s for power circuit, 60 A 50 °C - 30 s for power circuit, 45 A 50 °C - 1 min for power circuit, 40 A 50 °C - 3 min for power circuit, 20 A 50 °C - >= 15 min for power circuit
    • IE Rated Operational Current : 20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit, 16 A (at <70 °C) at 690 V AC AC-1 for power circuit
    • UI Rated Insulation Voltage : power circuit 600 V UL 508, power circuit 690 V IEC 60947-4-1, power circuit 600 V CSA C22.2 No 14
    • Control Circuit Type : DC low consumption
    • Maximum Operating Rate : 3600 cyc/h
    • UC Control Circuit Voltage : 24 V DC
    • UE Rated Operational Voltage : power circuit 690 V AC 50/60 Hz
    • UIMP Rated Impulse Withstand Voltage : 8 kV
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Associated Fuse Rating : 25 A gG at <= 440 V for power circuit, 25 A aM for power circuit
    • Flame Retardance : V1 conforming to UL 94, requirement 2 conforming to NF F 16-101, requirement 2 conforming to NF F 16-102
    • Mechanical Robustness : shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27, shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27, vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6, vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6, shocks contactor opened, on X axis10 Gn for 11 ms IEC 60068-2-27, shocks contactor opened, on Y axis6 Gn for 11 ms IEC 60068-2-27, shocks contactor closed, on X axis15 Gn for 11 ms IEC 60068-2-27, shocks contactor closed, on Y axis10 Gn for 11 ms IEC 60068-2-27
    • Operating Time : 10...20 ms coil de-energisation and NO opening, 30...40 ms coil energisation and NO closing
    • Protective Treatment : TC IEC 60068, TC DIN 50016
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Tightening Torque : 0.8-1.3 N.m screw clamp terminals Philips No 2, 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm, 0.8-1.3 N.m screw clamp terminals pozidriv No 2
    • ICW Rated Short Time Withstand Current : 90 A 50 °C - 1 s for power circuit, 85 A 50 °C - 5 s for power circuit, 80 A 50 °C - 10 s for power circuit, 60 A 50 °C - 30 s for power circuit, 45 A 50 °C - 1 min for power circuit, 40 A 50 °C - 3 min for power circuit, 20 A 50 °C - >= 15 min for power circuit
    • IE Rated Operational Current : 20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit, 16 A (at <70 °C) at 690 V AC AC-1 for power circuit
    • Carbon Footprint Of The Distribution Phase A4 : 0.1905235553282351, 0.2 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.8 kg CO2 eq., 0.8109644246162977
    • Carbon Footprint Of The Installation Phase A5 : 0.02934090699742508, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 3 kg CO2 eq., 2.655077796450255
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 212 kg CO2 eq., 212.4465571653427
    • Connections Terminals : screw clamp terminals 1 1.5-4 mm²solid, screw clamp terminals 1 0.75-4 mm²flexible without cable end, screw clamp terminals 1 0.34-2.5 mm²flexible with cable end, screw clamp terminals 2 1.5-4 mm²solid, screw clamp terminals 2 0.75-4 mm²flexible without cable end, screw clamp terminals 2 0.34-1.5 mm²flexible with cable end
    • Add Ons : LA1KN11, LA1KN20, LA1KN02, LA2KT2E, LA2KT2U
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-08
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1503003
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant
    • ROHS EUR Full Compliance Status : Compliant
    • ROHS EUR Full Compliance Status Id : COMPLIANT
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • WD Status : 1 - GSC certified
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Average Impedance : 3 mOhm - Ith 20 A 50 Hz for power circuit
    • Coil Technology : built-in bidirectional peak limiting diode suppressor
    • Compatibility Code : LP5K
    • Contactor Application : resistive load
    • Device Short Name : LP5K
    • Electrical Durability : 0.16 Mcycles 20 A AC-1 <= 690 V
    • Heat Dissipation : 1.8-1.8 W
    • Hold In Power Consumption In W : 1.8-1.8 W 20 °C
    • Inrush Power In W : 1.8-1.8 W 20 °C)
    • Interlocking Type : mechanical
    • Package Weight Lbs : 450.000 g
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : changeover contactor
    • Range : TeSys
    • Range Of Product : TeSys K
    • Returnability : No
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 216 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • ITH Conventional Free Air Thermal Current : 20 A (at 50 °C) for power circuit
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP1503003
    • Pep Verification Date : 2025-11-21
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional Unit Unit : unit
    • Product Kit Identifier : N
    • Product Manager : NANNAN YAN
  • Environment Attributes Main
    • EU ROHS Directive : Compliant​, Compliant
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Reach Free SHVC : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 216.13246384873491
    • Circularity Profile : ENVEOLI1503003
    • Environmental Disclosure : ENVPEP1503003
    • IP Degree Of Protection : IP20 VDE 0106
    • Operating Altitude : 6561.68 ft (2000 m) without derating
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of SVHC : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1503003
    • Pep Verification Date : 2025-11-21
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : changeover contactor
    • Range Of Product : TeSys K
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Overview Attributes
    • Device Presentation : preassembled with reversing power busbar