Contactor, TeSys K, 4P, 4 NO, AC-1, lt or eq to 440V 10A, 110VAC coil

CONTACTOR 600VAC 9AMP IEC +OPT

SQDLC1K09004F7 LC1K09004F7 3389110488425
100.47 / EA
http://schema.org/OutOfStock
  • Depth: 57 mm
  • Warranty Length: 18 mth
TeSys K contactor, 4 poles (4NO), for non-inductive load control applications up to 20A/690V AC-1. It provides a 110V 50/60Hz AC coil, without built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC).
QTY
  • Product Description
  • Features
  • Specifications
TeSys K contactor, 4 poles (4NO), for non-inductive load control applications up to 20A/690V AC-1. It provides a 110V 50/60Hz AC coil, without built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Assets
    • Cad : https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003365_3D-CAD&p_File_name=MCADPP0003365_3D-simplified.stp, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003365_3D-CAD&p_File_name=MCADPP0003365_2D-back.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003365_3D-CAD&p_File_name=MCADPP0003365_2D-back.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003365_3D-CAD&p_File_name=MCADPP0003365_2D-bottom.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003365_3D-CAD&p_File_name=MCADPP0003365_2D-bottom.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003365_3D-CAD&p_File_name=MCADPP0003365_2D-front.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003365_3D-CAD&p_File_name=MCADPP0003365_2D-front.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003365_3D-CAD&p_File_name=MCADPP0003365_2D-isometric.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003365_3D-CAD&p_File_name=MCADPP0003365_2D-isometric.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003365_3D-CAD&p_File_name=MCADPP0003365_2D-left.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003365_3D-CAD&p_File_name=MCADPP0003365_2D-left.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003365_3D-CAD&p_File_name=MCADPP0003365_2D-right.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003365_3D-CAD&p_File_name=MCADPP0003365_2D-right.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003365_3D-CAD&p_File_name=MCADPP0003365_2D-top.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003365_3D-CAD&p_File_name=MCADPP0003365_2D-top.dxf
  • Conformance Attributes
    • Product Certifications : CB Scheme, CCC, UL, CSA, EAC, CE, UKCA
    • Standards : EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, IEC 60335-1:Clause 30.2, IEC 60335-2-40:Annex JJ, UL 60335-2-40:Annex JJ
  • Complementary Attributes
    • Control Circuit Voltage Limits : operational: 0.8...1.15 Uc (at <50 °C), drop-out: >= 0.20 Uc (at <50 °C)
    • Rated Breaking Capacity : 110 A at 220...230 V conforming to IEC 60947, 110 A at 380...400 V conforming to IEC 60947, 110 A at 415 V conforming to IEC 60947, 110 A at 440 V conforming to IEC 60947, 80 A at 500 V conforming to IEC 60947, 70 A at 660...690 V conforming to IEC 60947
    • Icw Rated Short Time Withstand Current : 90 A 50 °C - 1 s for power circuit, 85 A 50 °C - 5 s for power circuit, 80 A 50 °C - 10 s for power circuit, 60 A 50 °C - 30 s for power circuit, 45 A 50 °C - 1 min for power circuit, 40 A 50 °C - 3 min for power circuit, 20 A 50 °C - >= 15 min for power circuit
    • Uc Control Circuit Voltage : 110 V AC 50/60 Hz, 110 V
    • Ue Rated Operational Voltage : power circuit <= 690 V AC <= 400 Hz, signalling circuit <= 690 V AC <= 400 Hz
    • Ui Rated Insulation Voltage : power circuit 600 V UL 508, power circuit 690 V IEC 60947-4-1, power circuit 600 V CSA C22.2 No 14
    • Control Circuit Type : AC 50/60 Hz
    • Irms Rated Making Capacity : 110 A AC for power circuit conforming to IEC 60947
    • Maximum Operating Rate : 3600 cyc/h
    • Ie Rated Operational Current : 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
    • Uimp Rated Impulse Withstand Voltage : 8 kV
  • Important Information Attributes
    • Html Descr : TeSys K Contactor
    • Number of Poles: 4-Poles
    • Pole Contact Composition: 4 NO
    • Rated Operational Current: 20A at <+ 400V AC-1 for power current
    • Control Circuit Voltage: 110V AC 50/60 Hz
    • Reversing
    , TeSys K Contactor
  • Number of Poles: 4-Poles
  • Pole Contact Composition: 4 NO
  • Rated Operational Current: 20A at <+ 400V AC-1 for power current
  • Control Circuit Voltage: 110V AC 50/60 Hz
  • Reversing
  • Persona Type Ids : EU, LC, OM, OM8, PB, SI
  • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
  • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
  • Market Segmentation : Commercial, Industrial
  • Associated Fuse Rating : 25 A gG at <= 440 V for power circuit, 25 A aM for power circuit
  • Flame Retardance : V1 conforming to UL 94, requirement 2 conforming to NF F 16-101, requirement 2 conforming to NF F 16-102
  • Mechanical Robustness : shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27, shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27, shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27, shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27, shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27, shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27, vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6, vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
  • Mounting Support : rail, plate
  • Operating Time : 10...20 ms coil de-energisation and NO opening, 10...20 ms coil energisation and NO closing
  • Protective Treatment : TC IEC 60068, TC DIN 50016
  • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Signalling Circuit Frequency : <= 400 Hz, <= 400 Hz, <= 400 Hz, <= 400 Hz
  • Tightening Torque : 0.8-1.3 N.m screw clamp terminals Philips No 2, 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm, 0.8-1.3 N.m screw clamp terminals pozidriv No 2
  • Connections Terminals : screw clamp terminals 2 0.75-4 mm²flexible without cable end, screw clamp terminals 2 0.34-1.5 mm²flexible with cable end, screw clamp terminals, screw clamp terminals 1 1.5-4 mm²solid, screw clamp terminals 1 0.75-4 mm²flexible without cable end, screw clamp terminals 1 0.34-2.5 mm²flexible with cable end, screw clamp terminals 2 1.5-4 mm²solid
  • Icw Rated Short Time Withstand Current : 90 A 50 °C - 1 s for power circuit, 85 A 50 °C - 5 s for power circuit, 80 A 50 °C - 10 s for power circuit, 60 A 50 °C - 30 s for power circuit, 45 A 50 °C - 1 min for power circuit, 40 A 50 °C - 3 min for power circuit, 20 A 50 °C - >= 15 min for power circuit
  • Ith Conventional Free Air Thermal Current : 20 A (at 60 °C) for power circuit, 10 A (at 50 °C) for signalling circuit
  • Carbon Footprint Of The Distribution Phase A4 : 0.0699882448144537, 0.1 kg CO2 eq.
  • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.2979052988386399, 0.3 kg CO2 eq.
  • Carbon Footprint Of The Installation Phase A5 : 0 kg CO2 eq., 0.010778292366401048
  • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 1 kg CO2 eq., 0.9753347007368284
  • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 89 kg CO2 eq., 88.5193988188928
  • Medium Desc : Contactor, TeSys K, 4P, 4 NO, AC-1, lt or eq to 440V 10A, 110VAC coil
  • Local Data Status : Publishable
  • Local Publishable Date : 2025-02-26
  • Global Commercial Status : Commercialised
  • Return Indicator : Y
  • Stocking Flag : N
  • Manufacturer : Schneider Electric
  • Device Type : LV equipment - LV contactor
  • Serviceability : No
  • Traceability : No
  • Field Service Division : PPIBS
  • Average Life Duration : 20 year(s)
  • Legacy Weee Scope : In
  • Scope Perimeter : At least in Europe
  • Eoli Availability Display : Yes
  • End Of Life Doc Ref : ENVEOLI1503003
  • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
  • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
  • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
  • Rohs Eur In Scope : Yes
  • Rohs Eur Status : Compliant
  • Rohs Eur Full Compliance Status : Compliant
  • With Recycled Cardboard : Yes
  • Without Single Use Plastic : Yes
  • Product Contributes To Saved And Avoided Emissions : No
  • Function Option Id : STANDARD
  • Function Option : Standard
  • Product Kit Identifier : N
  • Average Impedance : 3 mOhm - Ith 20 A 50 Hz for power circuit
  • Coil Technology : without built-in suppressor module
  • Compatibility Code : LC1K
  • Contactor Application : resistive load
  • Device Application : control
  • Device Short Name : LC1K
  • Electrical Durability : 0.16 Mcycles 20 A AC-1 <= 690 V
  • Heat Dissipation : 1.3-1.3 W
  • Hold In Power Consumption In Va : 4.5-4.5 VA (at 20 °C)
  • Inrush Power In Va : 30-30 VA (at 20 °C)
  • Mechanical Durability : 10 Mcycles
  • Overvoltage Category : III
  • Pole Contact Composition : 4 NO
  • Poles Description : 4P
  • Product Availability : Stock - Normally stocked in distribution facility
  • Product Or Component Type : contactor
  • Range : TeSys
  • Range Of Product : TeSys K
  • Returnability : Yes
  • Software Version : v6.2.4
  • Sustainable Packaging : Yes
  • Total Lifecycle Carbon Footprint : 90 kg CO2 eq.
  • Utilisation Category : AC-1
  • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
  • Ie Rated Operational Current : 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
  • Rated Thermal Current Ith : 20 A
  • Pep Code : ENVPEP1503003
  • Database Version : 2024-01
  • Pep Verification Date : 2025-11-21
  • Pcr Version : PEP-PCR-ed4-2021 09 06
  • Psr Version : PSR-0005-ed3-2023 06 06
  • Type Of Verification For The Pep : Independent internal review
  • Data Source : extrapolated product
  • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
  • Functional Unit Unit : unit
  • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Low voltage; 2020; France, FR
  • Energy Model Installation A5 2 : No energy used
  • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2020; Europe, EU-27
  • Energy Model End Of Life C1 C4 2 : Global, European and French datasets are used.
  • Height Nominal : 58 mm
  • Width Nominal : 45 mm
  • Environment Attributes Main
    • Ambient Air Temperature For Storage : -50-80 °C, -50-80 °C
    • Take Back : Nej
    • Reach Free Shvc : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 89.87340535564913
    • Circularity Profile : ENVEOLI1503003
    • Environmental Disclosure : ENVPEP1503003
    • Eu Rohs Directive : Compliant
    • Ip Degree Of Protection : IP2X VDE 0106
    • Operating Altitude : 6561.68 ft (2000 m) without derating
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1503003
    • Pep Verification Date : 2025-11-21
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : contactor
    • Range Of Product : TeSys K
  • ETIM
    • ETIM 8 : EC000066
    • ETIM 9 : EC000066
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Depth : 57 mm