Contactor, IEC, TeSys K, 9A, 3 P, 5 HP at 480VAC, nonreversing, 1 NO auxilliary contact, 120VAC 50/60 Hz coil

SQD LC1K0910G7 CONTACTOR 575VA

SQDLC1K0910G7 LC1K0910G7 3389110604160
89.64 / EA
http://schema.org/OutOfStock
  • Country of Origin: Indonesia
  • Depth: 57 mm
  • Height: 58 mm
  • Warranty Length: 18 mth
  • Width: 45 mm
TeSys K contactors have been designed for perfect integration into control systems. They can be used to create motor starters for any type of application. They can be used to create motor starters for almost any type of application. TeSys K contactors offer quick simple setup, while maintaining a compact size. Contactors have both Horsepower and Kw motor rating for international acceptance. An extennsive line of accessories makes it easy to meet the requirements of most applications. These contactors are UL Listed and CSA certified. Multi standards certified (IEC, UL, CSA, CCC, EAC).
QTY
  • Product Description
  • Features
  • Specifications
TeSys K contactors have been designed for perfect integration into control systems. They can be used to create motor starters for any type of application. They can be used to create motor starters for almost any type of application. TeSys K contactors offer quick simple setup, while maintaining a compact size. Contactors have both Horsepower and Kw motor rating for international acceptance. An extennsive line of accessories makes it easy to meet the requirements of most applications. These contactors are UL Listed and CSA certified. Multi standards certified (IEC, UL, CSA, CCC, EAC).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Product Certifications : CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
    • Flame Retardance : V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
    • Operating Altitude : 6561.68 ft (2000 m) without derating
    • Standards : EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ
    • Protective Treatment : TC IEC 60068 || TC DIN 50016
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Mercury Free : Yes
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Reach Free Of Svhc : Yes
    • Take-Back : No
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 0.9753347007368284
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 53 kg CO2 eq.
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 52.695257851714146
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Environmental Disclosure : ENVPEP1503003
    • Packaging Without Single Use Plastic : Yes
    • Toxic Heavy Metal Free : Yes
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Carbon Footprint Of The Installation Phase [A5] : 0.010778292366401048
    • Circularity Profile : ENVEOLI1503003
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 51.34125131495782
    • Carbon Footprint Of The End-Of-Life Phase [C1 To C4] : 0.3 kg CO2 eq.
    • Carbon Footprint Of The Distribution Phase [A4] : 0.1 kg CO2 eq.
    • Eu Rohs Directive : Compliant
  • Complementary
    • Minimum Switching Current : 5 mA for signalling circuit
    • [Uc] Control Circuit Voltage : 120 V AC 50/60 Hz
    • [Ue] Rated Operational Voltage : power circuit <= 690 V AC <= 400 Hz || signalling circuit <= 690 V AC <= 400 Hz
    • Average Impedance : 3 mOhm - Ith 20 A 50 Hz for power circuit
    • Auxiliary Contact Composition : 1 NO
    • Non Overlap Distance : 0.5 mm
    • Insulation Resistance : > 10 MOhm for signalling circuit
    • Inrush Power In Va : 30-30 VA (at 20 °C)
    • [Uimp] Rated Impulse Withstand Voltage : 8 kV
    • Pole Contact Composition : 3 NO
    • Utilisation Category : AC-3 || AC-3e || AC-1 || AC-4
    • [Ie] Rated Operational Current : 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit || 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
    • Maximum Operating Rate : 3600 cyc/h
    • Auxiliary Contacts Type : instantaneous 1 NO
    • Poles Description : 3P
    • Hold-In Power Consumption In Va : 4.5-4.5 VA (at 20 °C)
    • Operating Time : 10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing
    • Width : 45 mm
    • Overvoltage Category : III
    • Depth : 57 mm
    • Mechanical Robustness : shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 || vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 || vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
    • Height : 58 mm
    • Control Circuit Voltage Limits : operational: 0.8...1.15 Uc (at <50 °C) || drop-out: >= 0.20 Uc (at <50 °C)
    • [Ith] Conventional Free Air Thermal Current : 20 A (at 60 °C) for power circuit || 10 A (at 50 °C) for signalling circuit
    • Control Circuit Type : AC 50/60 Hz
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Rated Breaking Capacity : 110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conforming to IEC 60947
    • Irms Rated Making Capacity : 110 A AC for power circuit conforming to IEC 60947 || 110 A AC for signalling circuit conforming to IEC 60947
    • Associated Fuse Rating : 25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for signalling circuit conforming to IEC 60947 || 10 A gG for signalling circuit conforming to VDE 0660
    • Motor Power Kw : 2.2 kW 220...230 V AC 50/60 Hz AC-3 || 4 kW 380...415 V AC 50/60 Hz AC-3 || 4 kW 440/690 V AC 50/60 Hz AC-3 || 2.2 kW 220...230 V AC 50/60 Hz AC-3e || 4 kW 380...415 V AC 50/60 Hz AC-3e || 4 kW 440/690 V AC 50/60 Hz AC-3e || 2.2 kW 220...230 V AC 50/60 Hz AC-4 || 4 kW 380...415 V AC 50/60 Hz AC-4 || 4 kW 440/690 V AC 50/60 Hz AC-4
    • Connections - Terminals : screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4 mm²flexible without cable end || screw clamp terminals 2 0.34-1.5 mm²flexible with cable end
    • Minimum Switching Voltage : 17 V for signalling circuit
    • Signalling Circuit Frequency : <= 400 Hz
    • Electrical Durability : 1.3 Mcycles 9 A AC-3 <= 440 V || 1.3 Mcycles 9 A AC-3e <= 440 V || 0.16 Mcycles 20 A AC-1 <= 690 V || 0.02 Mcycles 54 A AC-4 <= 440 V
    • Mechanical Durability : 10 Mcycles
    • [Icw] Rated Short-Time Withstand Current : 90 A 50 °C - 1 s for power circuit || 85 A 50 °C - 5 s for power circuit || 80 A 50 °C - 10 s for power circuit || 60 A 50 °C - 30 s for power circuit || 45 A 50 °C - 1 min for power circuit || 40 A 50 °C - 3 min for power circuit || 20 A 50 °C - >= 15 min for power circuit || 80 A - 1 s for signalling circuit || 90 A - 500 ms for signalling circuit || 110 A - 100 ms for signalling circuit
    • Heat Dissipation : 1.3-1.3 W
  • Specifications
    • Country of Origin : Indonesia
    • Width : 45 mm
    • Height : 58 mm
    • Contactor Application : motor control || resistive load
    • Product Or Component Type : contactor
    • Range : TeSys
    • Device Application : control
    • Device Short Name : LC1K