TeSys D IEC contactor, 40 A, 3 P, 30 HP at 480 VAC, nonreversing, 120 VAC 50/60 Hz coil

IEC CONTACTOR 40A/3P/120V COIL

SQDLC1D40G7 LC1D40G7 3389110948561
411.10 / EA
http://schema.org/OutOfStock
  • Warranty Length: 18 mth
TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 40A/690V AC-3 (18.5kW@400V). They can be used to create motor starters for almost any type of application. It provides a 120V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), power connection by screw terminals, control connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (75mm width), DIN-rail mounting or screw fixing. These contactors have UL, CSA, GOST, RINA, BV, CCC, DNV, GL, LROS certifications. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 40A/690V AC-3 (18.5kW@400V). They can be used to create motor starters for almost any type of application. It provides a 120V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), power connection by screw terminals, control connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (75mm width), DIN-rail mounting or screw fixing. These contactors have UL, CSA, GOST, RINA, BV, CCC, DNV, GL, LROS certifications. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Standards : UL 60947-4-1, IEC 60947-4-1, CSA C22.2 No 14, EN 60947-4-1, IEC 60947-5-1, EN 60947-5-1
  • Complementary Attributes
    • Control Circuit Voltage Limits : 0.3...0.6 Uc (60-60 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (60-60 °C):operational AC 50 Hz, 0.85...1.1 Uc (60-60 °C):operational AC 60 Hz
    • IRMS Rated Making Capacity : 140 A AC for control circuit conforming to IEC 60947-5-1, 800 A at 440 V for power circuit conforming to IEC 60947
    • Maximum Horse Power Rating : 10 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to CSA, 10 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to UL, 10 hp at 230/240 V AC 60 Hz for 3 phase motors conforming to CSA, 10 hp at 230/240 V AC 60 Hz for 3 phase motors conforming to UL, 3 hp at 115 V AC 60 Hz for 1 phase motors conforming to CSA, 3 hp at 115 V AC 60 Hz for 1 phase motors conforming to UL, 30 hp at 460/480 V AC 60 Hz for 3 phase motors conforming to CSA, 30 hp at 460/480 V AC 60 Hz for 3 phase motors conforming to UL, 30 hp at 575/600 V AC 60 Hz for 3 phase motors conforming to CSA, 30 hp at 575/600 V AC 60 Hz for 3 phase motors conforming to UL, 5 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to CSA, 5 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to UL
    • IE Rated Operational Current : 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
    • UI Rated Insulation Voltage : control circuit 600 V CSA, control circuit 600 V UL, power circuit 600 V CSA, power circuit 600 V UL, control circuit 690 V IEC 60947-1, power circuit 690 V IEC 60947-1
    • Control Circuit Type : AC 50/60 Hz
    • Maximum Motor Phase Current : 40 A
    • Maximum Operating Rate : 3600 cyc/h at 60 °C
    • Minimum Switching Current : 5 mA for control circuit
    • Minimum Switching Voltage : 17 V for control circuit
    • Rated Breaking Capacity : 800 A at 440 V for power circuit conforming to IEC 60947
    • UC Control Circuit Voltage : 120 V AC 50/60 Hz
    • UE Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz
    • UIMP Rated Impulse Withstand Voltage : 6 kV IEC 60947
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Associated Fuse Rating : 10 A gG for control circuit conforming to IEC 60947-5-1, 80 A gG at <= 690 V coordination type 1 for power circuit, 80 A gG at <= 690 V coordination type 2 for power circuit
    • Contactor Application : resistive load, motor control
    • Hold In Power Consumption In VA : 13-13 VA 50 Hz cos phi 0.3 (at 20 °C), 15-15 VA 60 Hz cos phi 0.3 (at 20 °C)
    • Inrush Power In VA : 140-140 VA cos phi 0.75 (at 20 °C), 160-160 VA cos phi 0.75 (at 20 °C)
    • Insulation Resistance : > 10 MOhm for control circuit, > 10 MOhm for control circuit
    • Mechanical Robustness : shocks contactor opened 10 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms), vibrations contactor opened 2 Gn, 5...300 Hz), vibrations contactor closed 4 Gn, 5...300 Hz)
    • Motor Power KW : 18.5 kW at 380...400 V AC 50/60 Hz (AC-3), 22 kW at 1000 V AC 50/60 Hz (AC-3), 22 kW at 415 V AC 50/60 Hz (AC-3), 22 kW at 440 V AC 50/60 Hz (AC-3), 22 kW at 500 V AC 50/60 Hz (AC-3), 30 kW at 660...690 V AC 50/60 Hz (AC-3), 11 kW at 220...230 V AC 50/60 Hz (AC-3), 9 kW at 400 V AC 50/60 Hz (AC-4)
    • Non Overlap Time : 1.5 ms on de-energisation between NC and NO contacts, 1.5 ms on energisation between NC and NO contacts
    • Operating Time : 12...26 ms closing, 4...19 ms opening
    • Power Dissipation Per Pole : 5.4 W AC-1, 2.4 W AC-3
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Tightening Torque : control circuit 1.7 N.m screw clamp terminal flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminal Philips No 2, power circuit 5 N.m screw clamp terminal flat Ø 6 mm, power circuit 5 N.m screw clamp terminal flat Ø 8 mm
    • IE Rated Operational Current : 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
    • ITH Conventional Free Air Thermal Current : 10 A (at 60 °C) for control circuit, 60 A (at 60 °C) for power circuit
    • Carbon Footprint Of The Distribution Phase A4 : 0.1760063361869087, 0.2 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 3.328416174215296, 3 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0.3 kg CO2 eq., 0.2523595925959343
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 9 kg CO2 eq., 8.921945858891672
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 40 kg CO2 eq., 39.799710144927516
    • Connections Terminals : control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 2.5-35 mm² - cable stiffness: solid with cable end, power circuit: screw clamp terminals 2 2.5-35 mm² - cable stiffness: solid with cable end, power circuit: screw clamp terminals 1 2.5-35 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 2.5-25 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 2.5-35 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 2 2.5-35 mm² - cable stiffness: flexible with cable end
    • Auxiliaries : LADN22, LADN11, LADN20, LAD8N11, LADT2, LADN40, LADN31, LADN02, LADT0
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-04-04
    • HTML Description : TeSys D ContactorNumber of Poles: 3-PolesPole Contact Composition: 3 NORated Operational Current: 40AControl Circuit Voltage: 120V AC 50/60 HzNon-Reversing
    • Manufacturer : Schneider Electric
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant
    • ROHS EUR Full Compliance Status : Compliant
    • ROHS EUR Full Compliance Status Id : COMPLIANT
    • China ROHS In Scope : No
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Average Impedance : 1.5 mOhm - Ith 60 A 50 Hz for power circuit
    • Coil Technology : without built-in bidirectional peak limiting diode suppressor
    • Compatibility Code : LC1D
    • Device Short Name : LC1D
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Flame Retardance : V1 conforming to UL 94
    • Heat Dissipation : 4-5 W at 50/60 Hz for control circuit
    • Package Weight Lbs : 1.445 kg
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Range : TeSys
    • Range Of Product : TeSys Deca
    • Returnability : Yes
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 52 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Relationship Type : Compatible relationship
    • Add Ons : LAD4RCU
    • Pep Code : ENVPEP1102005EN
    • Pep Verification Date : 2025-11-20
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : Switch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control. The functional unit is characterized by a type 3P(3NO), a control circuit voltage 230V AC, a power circuit voltage 690V and a rated operational current 80A
    • Functional Unit Unit : unit
    • Product Kit Identifier : N
    • Product Manager : NANNAN YAN
  • Environment Attributes Main
    • EU ROHS Directive : Compliant​, Compliant
    • IP Degree Of Protection : IP2X IEC 60529, IP2X VDE 0106
    • Permissible Ambient Air Temperature Around The Device : -5-60 °C, -40-70 °C at Uc, -40-70 °C at Uc
    • Reach Regulation : Free of Substances of Very High Concern above the threshold, Reference contains Substances of Very High Concern above the threshold
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Reach Free SHVC : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 52.47843810681733
    • Climatic Withstand : IACS E10 exposure to damp heat
    • Environmental Disclosure : ENVPEP1102005EN
    • Operating Altitude : 9842.52 ft (3000 m) without derating
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of SVHC : Yes
    • Pep Code : ENVPEP1102005EN
    • Pep Verification Date : 2025-11-20
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months