Contactor, high power, TeSys Giga, standard version, 3 pole/NO, AC-3 <=440V 265A, 48-130VAC/DC coil

HIGH POWER CONTACTOR, TESYS GI

SQDLC1G265EHEN LC1G265EHEN 3606481921864
1168.88 / EA
http://schema.org/OutOfStock
TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 265A 160kW@440V. It provides a 48-130V AC/DC wide band low consumption electronic coil and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 290mm x 140mm x 209mm (H x W x D), compact size enables panel space savings. Multi standards certified (CE,CB,CCC,cULus,EAC,KC,RCM,Marine). Unique QR code provides quick access to complete product data.
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Physical Attributes
    • Color : dark grey
  • Conformance Attributes
    • Standards : EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, JIS C8201-5-1, IEC 60335-1:Clause 30.2, IEC 60335-2-40:Annex JJ, UL 60335-1, UL 60335-2-40:Annex JJ
  • Complementary Attributes
    • Control Circuit Voltage Limits : operational: 0.8 Uc Min...1.1 Uc Max (at <60 °C), drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C)
    • Maximum Horse Power Rating : 75 hp at 200/208 V 60 Hz, 100 hp at 230/240 V 60 Hz, 200 hp at 460/480 V 60 Hz, 200 hp at 575/600 V 60 Hz
    • Maximum Operating Rate : 600 cyc/h AC-3, 600 cyc/h AC-3e, 300 cyc/h AC-1, 150 cyc/h AC-4
    • ICW Rated Short Time Withstand Current : 2.2 kA - 10 s, 1.23 kA - 30 s, 0.95 kA - 1 min, 0.62 kA - 3 min, 0.48 kA - 10 min
    • IE Rated Operational Current : 385 A (at <40 °C) at <= 1000 V AC-1, 265 A (at <60 °C) at <= 440 V AC-3
    • UC Control Circuit Voltage : 48...130 V AC 50/60 Hz, 48...130 V DC
    • UE Rated Operational Voltage : <= 1000 V AC 50/60 Hz, <= 1000 V AC 50/60 Hz, <= 1000 V AC 50/60 Hz, <= 460 V DC, <= 460 V DC
    • IRMS Rated Making Capacity : 3320 A at 440 V
    • Maximum Motor Phase Current : 265 A
    • Rated Breaking Capacity : 2380 A at 440 V
    • UI Rated Insulation Voltage : 1000 V
    • UIMP Rated Impulse Withstand Voltage : 8 kV
  • Important Information Attributes
    • Persona Type Ids : EU, OM, OM8, PB
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Associated Fuse Rating : 315 A aM at <= 440 V for motor, 250 A aM at <= 690 V for motor, 400 A gG at <= 690 V, 450 A UL Type J at <= 600 V
    • Contactor Application : power switching, motor control
    • Electrical Durability : 300 cycles AC-1 400 V, 500 cycles AC-3 400 V, 500 cycles AC-3e 400 V, 150 cycles AC-4 400 V
    • Mechanical Robustness : vibrations 5-300 Hz 2 gn contactor open, vibrations 5-300 Hz 4 gn contactor closed, shocks 10 gn 11 ms contactor open, shocks 15 gn 11 ms contactor closed
    • Motor Power KW : 75 kW at 230 V AC 50/60 Hz (AC-3e), 132 kW at 400 V AC 50/60 Hz (AC-3e), 132 kW at 415 V AC 50/60 Hz (AC-3e), 160 kW at 440 V AC 50/60 Hz (AC-3e), 160 kW at 500 V AC 50/60 Hz (AC-3e), 200 kW at 690 V AC 50/60 Hz (AC-3e), 160 kW at 1000 V AC 50/60 Hz (AC-3e), 75 kW at 230 V AC 50/60 Hz (AC-3), 132 kW at 400 V AC 50/60 Hz (AC-3), 132 kW at 415 V AC 50/60 Hz (AC-3), 160 kW at 440 V AC 50/60 Hz (AC-3), 160 kW at 500 V AC 50/60 Hz (AC-3), 200 kW at 690 V AC 50/60 Hz (AC-3), 160 kW at 1000 V AC 50/60 Hz (AC-3), 75 kW at 230 V AC 50/60 Hz (AC-4), 132 kW at 400 V AC 50/60 Hz (AC-4), 132 kW at 415 V AC 50/60 Hz (AC-4), 150 kW at 440 V AC 50/60 Hz (AC-4), 160 kW at 500 V AC 50/60 Hz (AC-4), 160 kW at 690 V AC 50/60 Hz (AC-4), 160 kW at 1000 V AC 50/60 Hz (AC-4)
    • Operating Time : 40...70 ms closing, 15...50 ms opening
    • Power Dissipation Per Pole : 20 W AC-1 - Ith 385 A, 11 W AC-3 - Ith 265 A
    • Safety Reliability Level : B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1, B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
    • ICW Rated Short Time Withstand Current : 2.2 kA - 10 s, 1.23 kA - 30 s, 0.95 kA - 1 min, 0.62 kA - 3 min, 0.48 kA - 10 min
    • IE Rated Operational Current : 385 A (at <40 °C) at <= 1000 V AC-1, 265 A (at <60 °C) at <= 440 V AC-3
    • Carbon Footprint Of The Distribution Phase A4 : 2.4783286396827537, 2 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 18.149572229660926, 18 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 47 kg CO2 eq., 47.41714825410299
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 1 090 kg CO2 eq., 1089.6975
    • Connections Terminals : power circuit: bar 2 - busbar cross section: 32 x 10 mm, power circuit: lugs-ring terminals 1 185-185 mm², power circuit: bolted connection, control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end, control circuit: push-in 1 0.25-2.5 mm² - cable stiffness: flexible with cable end, control circuit: push-in 2 0.5-1.0 mm² with cable end, control circuit: push-in 0.75-2.5 mm² - cable stiffness: solid stranded without cable end, control circuit: push-in 0.75-2.5 mm² - cable stiffness: flexible with cable end
    • Auxiliaries : LAG8N113P, LAG8N113, LAG8N203P, LAG8N203
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-05-31
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • WEEE Scope : In
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2105013
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status Id : COMPLIANT_WITH_EXEMPTIONS
    • China ROHS In Scope : No
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Average Impedance : 0.000144 Ohm
    • Coil Technology : built-in bidirectional peak limiting
    • Compatibility Code : LC1G
    • Device Short Name : LC1G
    • Halogen Free Status : Halogen free plastic parts product
    • Hold In Power Consumption In VA : 17.6-17.6 VA
    • Hold In Power Consumption In W : 7.8-7.8 W
    • Inrush Power In VA : 780-780 VA
    • Inrush Power In W : 695 W
    • Mechanical Durability : 8 Mcycles
    • Package Weight Lbs : 7.478 kg
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Protective Treatment : TH
    • Range : TeSys
    • Range Of Product : TeSys Giga
    • Returnability : Yes
    • Sustainable Packaging : Yes
    • Tightening Torque : 35 N.m
    • Total Lifecycle Carbon Footprint : 1 158 kg CO2 eq.
    • Variant : standard
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • ITH Conventional Free Air Thermal Current : 385 A (at 40 °C)
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP2105013EN
    • Pep Verification Date : 2025-06-17
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Rated Thermal Current Ith : 385 A
    • Functional Unit Description : Switch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control. The functional unit is characterized by a type 3P(NO), a control circuit voltage 100V-250V AC/DC, a power circuit voltage 1000V AC and a rated operational current 225A.
    • Functional Unit Unit : Unit
    • Product Kit Identifier : N
    • Product Manager : SHUREN ZHANG
  • Environment Attributes Main
    • EU ROHS Directive : Compliant By Exemption​, Compliant with Exemptions
    • IP Degree Of Protection : IP2X front face with shrouds IEC 60529, IP2X front face with shrouds VDE 0106
    • Permissible Ambient Air Temperature Around The Device : -40-70 °C at Uc, -40-70 °C at Uc
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Halogene Performance : Halogen free plastic parts product
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Mercury Free : Yes
    • Carbon Footprint : 1157.7425491234467
    • Circularity Profile : ENVEOLI2105013
    • Environmental Disclosure : ENVPEP2105013EN
    • Halogen Content Performance : Halogen free plastic parts product
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2105013EN
    • Pep Verification Date : 2025-06-17
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Giga