TeSys Deca, auxiliary contact block, 1 NO and 1 NC, side mount, screw clamp terminals, for LC1D09 to LC1D150 contactors

TeSys Deca, auxiliary contact block, 1 NO and 1 NC, side mount, screw clamp terminals, for LC1D09 to LC1D150 contactors

SQDLAD8N11 LAD8N11 3389110384673
32.03 / EA
http://schema.org/OutOfStock
  • Depth: 71.3 mm
  • Warranty Length: 18 mth
TeSys Deca instantaneous auxiliary contact block, for LC.D contactors and CAD control relays with AC coils only. It provides 1NO+1NC contacts (NC mirror certified) rated up to 10A 690V AC, connection by screw clamp terminals. Clip-on side mounting, it procures high reliability and durability. TeSys Deca contactors have been designed for perfect integration into control systems. Multi standards certified (IEC, UL, CSA, CCC, EAC). TeSys Deca contactors offer quick simple setup, while maintaining a compact size. Contactors have both horsepower and Kw motor rating for international acceptance. An extennsive line of accessories makes it easy to meet the requirements of most applications. These contactors have UL, CSA, GOST, RINA, BV, CCC, DNV, GL, LROS certifications.
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca instantaneous auxiliary contact block, for LC.D contactors and CAD control relays with AC coils only. It provides 1NO+1NC contacts (NC mirror certified) rated up to 10A 690V AC, connection by screw clamp terminals. Clip-on side mounting, it procures high reliability and durability. TeSys Deca contactors have been designed for perfect integration into control systems. Multi standards certified (IEC, UL, CSA, CCC, EAC). TeSys Deca contactors offer quick simple setup, while maintaining a compact size. Contactors have both horsepower and Kw motor rating for international acceptance. An extennsive line of accessories makes it easy to meet the requirements of most applications. These contactors have UL, CSA, GOST, RINA, BV, CCC, DNV, GL, LROS certifications.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Product Certifications : CB Scheme, UL, CSA, CCC, EAC, UKCA
    • Standards : EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, IEC 60335-1:Clause 30.2, IEC 60335-2-40:Annex JJ, UL 60335-2-40:Annex JJ
  • Complementary Attributes
    • Irms Rated Making Capacity : 140 A AC conforming to IEC 60947-5-1, 250 A DC conforming to IEC 60947-5-1
    • Ie Rated Operational Current : 6 A at 120 V AC-15, 1.04 A at 690 V AC-15, 0.55 A at 125 V DC-13, 0.1 A at 600 V DC-13
    • Ui Rated Insulation Voltage : 690 V IEC 60947-5-1, 600 V UL, 600 V CSA
    • Minimum Switching Current : 5 mA
    • Minimum Switching Voltage : 17 V
    • Ue Rated Operational Voltage : 690 V AC 25...400 Hz
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Insulation Resistance : > 10 MOhm, > 10 MOhm
    • Non Overlap Time : 1.5 ms on de-energisation no overlap between NC and NO contact, 1.5 ms on energisation no overlap between NC and NO contact
    • Permissible Short Time Rating : 100 A 1 s, 120 A 500 ms, 140 A 100 ms
    • Tightening Torque : 1.7 N.m flat Ø 6 mm, 1.7 N.m Philips No 2, 1.7 N.m pozidriv No 2
    • Connections Terminals : screw clamp terminals 2 1-4 mm²flexible without cable end, screw clamp terminals 2 1-4 mm²rigid without cable end, screw clamp terminals 1 1-4 mm²flexible with cable end, screw clamp terminals 1 1-4 mm²flexible without cable end, screw clamp terminals 2 1-2.5 mm²flexible with cable end, screw clamp terminals 1 1-4 mm²rigid without cable end
    • Ie Rated Operational Current : 6 A at 120 V AC-15, 1.04 A at 690 V AC-15, 0.55 A at 125 V DC-13, 0.1 A at 600 V DC-13
    • Carbon Footprint Of The Distribution Phase A4 : 0.06786586045038151, 0.1 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.2 kg CO2 eq., 0.15462428493948835
    • Carbon Footprint Of The Installation Phase A5 : 0.008480726561347006, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 0.4 kg CO2 eq., 0.41771858290220826
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 2 kg CO2 eq., 1.5803
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-03-25
    • Return Indicator : Y
    • Stocking Flag : Y
    • Stock Policy : 1
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Use Carbon Footprint : 1.5803
    • Legacy Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Conformity Date : 1929
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : No
    • China Rohs Label : 1
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Environmental Characteristic : normal environment
    • Mechanical Durability : 30 Mcycles
    • Mounting Location : side
    • Pole Contact Composition : 1 NO + 1 NC
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Name : TeSys Deca
    • Product Or Component Type : auxiliary contact block
    • Protection Type : gG fuse 10 A
    • Protective Treatment : TH IEC 60068
    • Range : TeSys
    • Range Of Product : TeSys Deca
    • Returnability : Yes
    • Shielding Continuity Terminal : without
    • Software Version : v5.9.4
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 2 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Ith Conventional Free Air Thermal Current : 10 A (at 60 °C)
    • Warranty In Months : 18
    • Pole Contact Comp : 1 NO + 1 NC
    • Pep Code : ENVPEP1108007EN
    • Database Version : 2022-01
    • Pep Verification Date : 2025-06-17
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : To add instantaneous auxiliary contact blocks in front face on TeSys k contactors as NO and NC contacts for 20 years.
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Product Weight In G2 : 55
    • Reference Lifetime In Y2 : 20
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model Installation A5 2 : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model Use B6 2 : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model End Of Life C1 C4 2 : Electricity Mix; Production mix; Low voltage; FR
    • Recyclability Potential In 2 : 39
    • Offer Owner Code : 190788
    • Height Nominal : 72 mm
    • Width Nominal : 12.5 mm
    • Climate Change Fossil Fuels Kg Co2 Eq Operational Energy Use B6 2 : 1.5762
    • Climate Change Total Kg Co2 Eq Operational Energy Use B6 2 : 1.5803
    • Depletion Of Abiotic Resources Fossil Fuels Mj Operational Energy Use B6 2 : 303.455
    • Ecotoxicity Fresh Water Ctue Operational Energy Use B6 2 : 11.1605
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Operational Energy Use B6 2 : 40.9625
    • Total Use Of Primary Energy During The Life Cycle Mj Operational Energy Use B6 2 : 331.51
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 2 : 28.0555
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 2 : 303.455
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 2 : 28.0555
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Take Back : No
    • Reach Free Shvc : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 2.2289894548534255
    • Ambient Air Temperature For Operation : -5-60 °C
    • Ambient Air Temperature For Storage : -60-80 °C
    • Environmental Disclosure : ENVPEP1108007EN
    • Eu Rohs Directive : Compliant
    • Ip Degree Of Protection : IP20 conforming to IEC 60529
    • Operating Altitude : 9842.52 ft (3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1108007EN
    • Pep Verification Date : 2025-06-17
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : auxiliary contact block
    • Range Of Product : TeSys Deca
  • ETIM
    • ETIM 8 : EC000041
    • ETIM 9 : EC000041
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Brazil, France, United Kingdom, Indonesia, United States
    • Depth : 71.3 mm