Contactor, Definite Purpose, 30A, 4 pole, 20HP at 575VAC, 3 phase, 110/120VAC 50/60Hz coil, open

Contactor, Definite Purpose, 30A, 4 pole, 20HP at 575VAC, 3 phase, 110/120VAC 50/60Hz coil, open

SQD8910DPA34V02 8910DPA34V02 785901073505
136.54 / EACH
http://schema.org/OutOfStock
  • Certifications: CSA, UL Recognized
  • Contact Configuration: 4 NO
  • Depth: 3.00 in, 76 mm
  • Height: 3.77 in, 95.80 mm
  • Line Rated Current: 30 A
  • Net Weight: .59 kg, 1.3 lb
  • Number of Phases: 3
  • Warranty Length: 18 mth
  • Width: 2.75 in, 69.80 mm
8910DP definite purpose magnetic contactors are designed for heating, air conditioning and refrigeration applications. This line of definite purpose contactors has current ratings up to 120 amperes resistive and 50 HP at 600 VAC. This four pole definite purpose contactor has a full load rating of 30 ampere and a resistive rating of 40 amperes. It also has a 2 HP at 115 VAC single phase, 5 HP at 230 VAC single phase and 10 HP at 230 VAC three phase, 15 HP at 460 VAC three phase and 20 HP at 575 VAC three phase. The nonreplaceable coil is available with a variety of coil voltages. This device has a 110/120 VAC 50/60 Hz coil. The contactor has straight through wiring. Contactor is 3.78 inches by 2.75 inches and 3.04 tall. These contactors are UL component recognized and CSA certified.
QTY
  • Product Description
  • Specifications
8910DP definite purpose magnetic contactors are designed for heating, air conditioning and refrigeration applications. This line of definite purpose contactors has current ratings up to 120 amperes resistive and 50 HP at 600 VAC. This four pole definite purpose contactor has a full load rating of 30 ampere and a resistive rating of 40 amperes. It also has a 2 HP at 115 VAC single phase, 5 HP at 230 VAC single phase and 10 HP at 230 VAC three phase, 15 HP at 460 VAC three phase and 20 HP at 575 VAC three phase. The nonreplaceable coil is available with a variety of coil voltages. This device has a 110/120 VAC 50/60 Hz coil. The contactor has straight through wiring. Contactor is 3.78 inches by 2.75 inches and 3.04 tall. These contactors are UL component recognized and CSA certified.
  • Environment
    • Product Certifications : UL Recognized || CSA
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Eu Rohs Directive : Compliant with Exemptions
  • Complementary
    • [Uc] Control Circuit Voltage : 120 V AC 60 Hz || 110 V AC 50 Hz
    • Height : 3.77 in || 95.80 mm
    • Locked Rotor Rated Current : 150 A 460 V AC || 120 A 575 V AC || 180 A 277 V AC
    • Maximum Horse Power Rating : 2-2 hp 115 V AC, 1 phase || 5-5 hp 230 V AC, 1 phase || 10-10 hp 230 V AC, 3 phase || 15-15 hp 460 V AC, 3 phase || 20-20 hp 575 V AC, 3 phase
    • Phase : 3 phase
    • Net Weight : .59 kg || 1.3 lb(US)
    • Electrical Connection : binder head || quick connect terminals
    • Width : 2.75 in || 69.80 mm
    • Depth : 3.00 in || 76 mm
    • [Ue] Rated Operational Voltage : 600 V AC
  • Specifications
    • Range Of Product : DPA
    • Product Or Component Type : Definite Purpose Contactor
    • Pole Contact Composition : 4 NO
    • Poles Description : 4P
    • Line Rated Current : 30 A