SQUARE D

Contactor, Definite Purpose, 30A, 2 pole, 208/240VAC coil at 60Hz, 220VAC 50Hz coil, open

SQD 8910DP32V09 CONTACTOR 600V

SQD8910DP32V09 8910DP32V09 785901073345
76.14 / EACH
http://schema.org/OutOfStock
  • Certifications: CSA, UL Recognized
  • Contact Configuration: 2 NO
  • Line Rated Current: 30 A
  • Number of Phases: 1
  • Warranty Length: 18 mth
8910DP definite purpose magnetic contactors are designed for heating, air conditioning and refrigeration applications. This line of definite purpose contactors has current ratings up to 120 amperes resistive and 50 HP at 600 VAC. This two pole definite purpose contactor has a full load rating of 30 ampere and a resistive rating of 40 amperes. The nonreplaceable coil is available with a variety of coil voltages. This device has a 208/240 VAC 60 Hz, 220 VAC 50 Hz coil. The contactor has straight through wiring. Contactor is 2.00 inches by 3.32 inches and 2.45 tall. These contactors are UL Listed and CSA Certified.
QTY
  • Product Description
  • Specifications
8910DP definite purpose magnetic contactors are designed for heating, air conditioning and refrigeration applications. This line of definite purpose contactors has current ratings up to 120 amperes resistive and 50 HP at 600 VAC. This two pole definite purpose contactor has a full load rating of 30 ampere and a resistive rating of 40 amperes. The nonreplaceable coil is available with a variety of coil voltages. This device has a 208/240 VAC 60 Hz, 220 VAC 50 Hz coil. The contactor has straight through wiring. Contactor is 2.00 inches by 3.32 inches and 2.45 tall. These contactors are UL Listed and CSA Certified.
  • Environment
    • Product Certifications : UL Recognized || CSA
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Eu Rohs Directive : Compliant with Exemptions
  • Complementary
    • [Uc] Control Circuit Voltage : 208...240 V AC 60 Hz || 220 V AC 50 Hz
    • Locked Rotor Rated Current : 125 A 460 V AC || 100 A 575 V AC || 150 A 277 V AC
    • Maximum Horse Power Rating : 2-2 hp 115 V AC, 1 phase || 5-5 hp 230 V AC, 1 phase
    • Phase : 1 phase
    • Electrical Connection : binder head || quick connect terminals
    • [Ue] Rated Operational Voltage : 600 V AC
  • Specifications
    • Range Of Product : DP
    • Product Or Component Type : Definite Purpose Contactor
    • Pole Contact Composition : 2 NO
    • Poles Description : 2P
    • Line Rated Current : 30 A