SQUARE D

Monolithic pilot light, Harmony XB5, grey plastic, green, 22mm, universal LED, plain lens, 230...240V AC

HARMONY XB5, MONOLITHIC PILOT

SQDXB5EVM3 XB5EVM3 3389119041614
23.44 / EA
http://schema.org/OutOfStock
  • Bezel Material: Plastic
  • Head Type: Standard
  • Warranty Length: 18 mth
This Harmony XB5, plain lens monolithic green pilot light is supplied with 230V to 240V AC, uses a universal LED and screw clamp terminals. This single component pilot light provides clear visual feedback on the status of your machines. It is easily installed into standard 22mm diameter cut-outs and connected with simple screw-clamp connections. It is clearly distinguishable visually at a distance due to clear colors and illumination via universal LED, enabling complex machine statuses to be read at a glance. It is impact resistant, dust resistant, water resistant and vibration resistant thanks to its IP66 / IP67 / IP69 / IP69K, making it ideal for operation in harsh environments. Its plastic bezel makes it ideal for applications requiring good resistance to chemical agents and/or double electrical insulation.
QTY
  • Product Description
  • Features
  • Specifications
This Harmony XB5, plain lens monolithic green pilot light is supplied with 230V to 240V AC, uses a universal LED and screw clamp terminals. This single component pilot light provides clear visual feedback on the status of your machines. It is easily installed into standard 22mm diameter cut-outs and connected with simple screw-clamp connections. It is clearly distinguishable visually at a distance due to clear colors and illumination via universal LED, enabling complex machine statuses to be read at a glance. It is impact resistant, dust resistant, water resistant and vibration resistant thanks to its IP66 / IP67 / IP69 / IP69K, making it ideal for operation in harsh environments. Its plastic bezel makes it ideal for applications requiring good resistance to chemical agents and/or double electrical insulation.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Standards : UL 508, IEC 60947-5-1, CSA C22.2 No 14, JIS C8201-5-1, IEC 60947-1, IEC 60947-5-4, JIS C8201-1
  • Complementary Attributes
    • UI Rated Insulation Voltage : 250 V 3)IEC 60947-1, 250 V 3)IEC 60947-1, 250 V 3)IEC 60947-1
    • UIMP Rated Impulse Withstand Voltage : 4 kV IEC 60947-1, 4 kV IEC 60947-1
    • US Rated Supply Voltage : 230...240 V AC 50/60 Hz, 230...240 V AC 50/60 Hz, 230...240 V AC 50/60 Hz
  • Environment Attributes Additional
    • Energy Model Manufacturing A1 A3 : Energy model used: Electricity Mix; Production mix; Low voltage; UE-27
    • Acidification Ap Mole Of H Equiv Total Life Cycle : 0.6230751954
    • Acidification Ap Mole Of H Equiv Manufacturing A1 A3 : 0.0012533333
    • Acidification Ap Mole Of H Equiv Distribution A4 : 0.0000210271
    • Acidification Ap Mole Of H Equiv Installation A5 : 0.0000385618
    • Acidification Ap Mole Of H Equiv Maintenance B2 : 0
    • Acidification Ap Mole Of H Equiv Repair B3 : 0
    • Acidification Ap Mole Of H Equiv Replacement B4 : 0
    • Acidification Ap Mole Of H Equiv Operational Energy Use B6 : 0.6216910648
    • Acidification Ap Mole Of H Equiv End Of Life C1 C4 : 0.0000712083
    • Acidification Ap Mole Of H Equiv Benefits Loads Beyond System Boundaries D : -0.0002000347
    • Climate Change Biogenics Kg Co2 Eq Total Life Cycle : 0.1001429181
    • Climate Change Biogenics Kg Co2 Eq Manufacturing A1 A3 : 0.0017805556
    • Climate Change Biogenics Kg Co2 Eq Distribution A4 : 0
    • Climate Change Biogenics Kg Co2 Eq Installation A5 : 0.0004318194
    • Climate Change Biogenics Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Biogenics Kg Co2 Eq Repair B3 : 0
    • Climate Change Biogenics Kg Co2 Eq Replacement B4 : 0
    • Climate Change Biogenics Kg Co2 Eq Operational Energy Use B6 : 0.0978969444
    • Climate Change Biogenics Kg Co2 Eq End Of Life C1 C4 : 0.0000335986
    • Climate Change Biogenics Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -0.0003990208
    • Climate Change Fossil Fuels Kg Co2 Eq Total Life Cycle : 102.01027125
    • Climate Change Fossil Fuels Kg Co2 Eq Manufacturing A1 A3 : 0.1889652778
    • Climate Change Fossil Fuels Kg Co2 Eq Distribution A4 : 0.0032691667
    • Climate Change Fossil Fuels Kg Co2 Eq Installation A5 : 0.0092833333
    • Climate Change Fossil Fuels Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Repair B3 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Replacement B4 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Operational Energy Use B6 : 101.7654166667
    • Climate Change Fossil Fuels Kg Co2 Eq End Of Life C1 C4 : 0.0433368056
    • Climate Change Fossil Fuels Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -0.0357736111
    • Climate Change Total Kg Co2 Eq Total Life Cycle : 102.1094187037
    • Climate Change Total Kg Co2 Eq Manufacturing A1 A3 : 0.19075
    • Climate Change Total Kg Co2 Eq Distribution A4 : 0.0032691667
    • Climate Change Total Kg Co2 Eq Installation A5 : 0.0097145833
    • Climate Change Total Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Total Kg Co2 Eq Repair B3 : 0
    • Climate Change Total Kg Co2 Eq Replacement B4 : 0
    • Climate Change Total Kg Co2 Eq Operational Energy Use B6 : 101.8623148148
    • Climate Change Total Kg Co2 Eq End Of Life C1 C4 : 0.0433701389
    • Climate Change Total Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -0.0361722222
    • Components For Re Use Kg Total Life Cycle : 0
    • Components For Re Use Kg Manufacturing A1 A3 : 0
    • Components For Re Use Kg Distribution A4 : 0
    • Components For Re Use Kg Installation A5 : 0
    • Components For Re Use Kg Maintenance B2 : 0
    • Components For Re Use Kg Repair B3 : 0
    • Components For Re Use Kg Replacement B4 : 0
    • Components For Re Use Kg Operational Energy Use B6 : 0
    • Components For Re Use Kg End Of Life C1 C4 : 0
    • Components For Re Use Kg Benefits Loads Beyond System Boundaries D : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Total Life Cycle : 0.0001879929
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Manufacturing A1 A3 : 0.0001830625
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Distribution A4 : 0.0000000001
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Installation A5 : 0.0000000003
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Maintenance B2 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Repair B3 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Replacement B4 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Operational Energy Use B6 : 0.0000049294
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb End Of Life C1 C4 : 0.0000000005
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb BLB SysBound D : -0.0000079639
    • Depletion Of Abiotic Resources Fossil Fuels Mj Total Life Cycle : 2163.829419213
    • Depletion Of Abiotic Resources Fossil Fuels Mj Manufacturing A1 A3 : 2.9554861111
    • Depletion Of Abiotic Resources Fossil Fuels Mj Distribution A4 : 0.0455465278
    • Depletion Of Abiotic Resources Fossil Fuels Mj Installation A5 : 0.1011180556
    • Depletion Of Abiotic Resources Fossil Fuels Mj Maintenance B2 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Repair B3 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Replacement B4 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Operational Energy Use B6 : 2159.7851851852
    • Depletion Of Abiotic Resources Fossil Fuels Mj End Of Life C1 C4 : 0.9420833333
    • Depletion Of Abiotic Resources Fossil Fuels Mj Benefits Loads Beyond System Boundaries D : -0.6770625
    • Ecotoxicity Fresh Water Ctue Total Life Cycle : 1371.2946929861
    • Ecotoxicity Fresh Water Ctue Manufacturing A1 A3 : 52.5854166667
    • Ecotoxicity Fresh Water Ctue Distribution A4 : 0.0021999306
    • Ecotoxicity Fresh Water Ctue Installation A5 : 0.0662986111
    • Ecotoxicity Fresh Water Ctue Maintenance B2 : 0
    • Ecotoxicity Fresh Water Ctue Repair B3 : 0
    • Ecotoxicity Fresh Water Ctue Replacement B4 : 0
    • Ecotoxicity Fresh Water Ctue Operational Energy Use B6 : 1318.1875
    • Ecotoxicity Fresh Water Ctue End Of Life C1 C4 : 0.4532777778
    • Ecotoxicity Fresh Water Ctue Benefits Loads Beyond System Boundaries D : -0.54125
    • Emission Of Fine Particles Incidence Of Diseases Total Life Cycle : 0.0000041915
    • Emission Of Fine Particles Incidence Of Diseases Manufacturing A1 A3 : 0.0000000154
    • Emission Of Fine Particles Incidence Of Diseases Distribution A4 : 0.0000000002
    • Emission Of Fine Particles Incidence Of Diseases Installation A5 : 0.0000000003
    • Emission Of Fine Particles Incidence Of Diseases Maintenance B2 : 0
    • Emission Of Fine Particles Incidence Of Diseases Repair B3 : 0
    • Emission Of Fine Particles Incidence Of Diseases Replacement B4 : 0
    • Emission Of Fine Particles Incidence Of Diseases Operational Energy Use B6 : 0.0000041753
    • Emission Of Fine Particles Incidence Of Diseases End Of Life C1 C4 : 0.0000000003
    • Emission Of Fine Particles Incidence Of Diseases BLB SysBound D : -0.0000000143
    • Exported Energy Mj By Energy Vector Total Life Cycle : 0
    • Exported Energy Mj By Energy Vector Manufacturing A1 A3 : 0
    • Exported Energy Mj By Energy Vector Distribution A4 : 0
    • Exported Energy Mj By Energy Vector Installation A5 : 0
    • Exported Energy Mj By Energy Vector Maintenance B2 : 0
    • Exported Energy Mj By Energy Vector Repair B3 : 0
    • Exported Energy Mj By Energy Vector Replacement B4 : 0
    • Exported Energy Mj By Energy Vector Operational Energy Use B6 : 0
    • Exported Energy Mj By Energy Vector End Of Life C1 C4 : 0
    • Exported Energy Mj By Energy Vector Benefits Loads Beyond System Boundaries D : 0
    • Freshwater Eutrophication Kg P Eq Total Life Cycle : 0.0001639712
    • Freshwater Eutrophication Kg P Eq Manufacturing A1 A3 : 0.0000020805
    • Freshwater Eutrophication Kg P Eq Distribution A4 : 0.0000000012
    • Freshwater Eutrophication Kg P Eq Installation A5 : 0.0000000702
    • Freshwater Eutrophication Kg P Eq Maintenance B2 : 0
    • Freshwater Eutrophication Kg P Eq Repair B3 : 0
    • Freshwater Eutrophication Kg P Eq Replacement B4 : 0
    • Freshwater Eutrophication Kg P Eq Operational Energy Use B6 : 0.000161805
    • Freshwater Eutrophication Kg P Eq End Of Life C1 C4 : 0.0000000143
    • Freshwater Eutrophication Kg P Eq Benefits Loads Beyond System Boundaries D : -0.000000141
    • Hazardous Waste Disposed Of Kg Total Life Cycle : 2.6346715532
    • Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 0.4215347222
    • Hazardous Waste Disposed Of Kg Distribution A4 : 0
    • Hazardous Waste Disposed Of Kg Installation A5 : 0.0001148403
    • Hazardous Waste Disposed Of Kg Maintenance B2 : 0
    • Hazardous Waste Disposed Of Kg Repair B3 : 0
    • Hazardous Waste Disposed Of Kg Replacement B4 : 0
    • Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 2.1931032407
    • Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.01991875
    • Hazardous Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -0.6288263889
    • Human Toxicity Carcinogenic Effects Ctuh Total Life Cycle : 0.0000000822
    • Human Toxicity Carcinogenic Effects Ctuh Manufacturing A1 A3 : 0.0000000666
    • Human Toxicity Carcinogenic Effects Ctuh Distribution A4 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Installation A5 : 0.0000000035
    • Human Toxicity Carcinogenic Effects Ctuh Maintenance B2 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Repair B3 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Replacement B4 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Operational Energy Use B6 : 0.0000000121
    • Human Toxicity Carcinogenic Effects Ctuh End Of Life C1 C4 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Benefits Loads Beyond System Boundaries D : -0.0000000953
    • Human Toxicity Non Carcinogenic Effects Ctuh Total Life Cycle : 0.0000005433
    • Human Toxicity Non Carcinogenic Effects Ctuh Manufacturing A1 A3 : 0.0000000029
    • Human Toxicity Non Carcinogenic Effects Ctuh Distribution A4 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Installation A5 : 0.0000000001
    • Human Toxicity Non Carcinogenic Effects Ctuh Maintenance B2 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Repair B3 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Replacement B4 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Operational Energy Use B6 : 0.0000005399
    • Human Toxicity Non Carcinogenic Effects Ctuh End Of Life C1 C4 : 0.0000000004
    • Human Toxicity Non Carcinogenic Effects Ctuh Benefits Loads Beyond System Boundaries D : -0.0000000016
    • Impacts Related To Land Use Soil Quality Total Life Cycle : 1.4128225926
    • Impacts Related To Land Use Soil Quality Manufacturing A1 A3 : 0.0047426389
    • Impacts Related To Land Use Soil Quality Distribution A4 : 0
    • Impacts Related To Land Use Soil Quality Installation A5 : 0
    • Impacts Related To Land Use Soil Quality Maintenance B2 : 0
    • Impacts Related To Land Use Soil Quality Repair B3 : 0
    • Impacts Related To Land Use Soil Quality Replacement B4 : 0
    • Impacts Related To Land Use Soil Quality Operational Energy Use B6 : 1.4056939815
    • Impacts Related To Land Use Soil Quality End Of Life C1 C4 : 0.0023859722
    • Impacts Related To Land Use Soil Quality Benefits Loads Beyond System Boundaries D : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Total Life Cycle : 88.1261694336
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Manufacturing A1 A3 : 0.2163402778
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Distribution A4 : 0.0000079521
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Installation A5 : 0.0004554444
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Maintenance B2 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Repair B3 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Replacement B4 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Operational Energy Use B6 : 87.9089814815
    • Ionizing Radiation Human Health Kbq Of U235 Equiv End Of Life C1 C4 : 0.0003842778
    • Ionizing Radiation Human Health Kbq Of U235 Equiv BLB SysBound D : -0.0054531944
    • Marine Aquatic Eutrophication Kg Of N Equiv Total Life Cycle : 0.0698341558
    • Marine Aquatic Eutrophication Kg Of N Equiv Manufacturing A1 A3 : 0.0002313472
    • Marine Aquatic Eutrophication Kg Of N Equiv Distribution A4 : 0.000009875
    • Marine Aquatic Eutrophication Kg Of N Equiv Installation A5 : 0.0000102125
    • Marine Aquatic Eutrophication Kg Of N Equiv Maintenance B2 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Repair B3 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Replacement B4 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Operational Energy Use B6 : 0.0695594537
    • Marine Aquatic Eutrophication Kg Of N Equiv End Of Life C1 C4 : 0.0000232674
    • Marine Aquatic Eutrophication Kg Of N Equiv Benefits Loads Beyond System Boundaries D : -0.0000272403
    • Materials For Energy Recovery Kg Total Life Cycle : 0
    • Materials For Energy Recovery Kg Manufacturing A1 A3 : 0
    • Materials For Energy Recovery Kg Distribution A4 : 0
    • Materials For Energy Recovery Kg Installation A5 : 0
    • Materials For Energy Recovery Kg Maintenance B2 : 0
    • Materials For Energy Recovery Kg Repair B3 : 0
    • Materials For Energy Recovery Kg Replacement B4 : 0
    • Materials For Energy Recovery Kg Operational Energy Use B6 : 0
    • Materials For Energy Recovery Kg End Of Life C1 C4 : 0
    • Materials For Energy Recovery Kg Benefits Loads Beyond System Boundaries D : 0
    • Materials For Recycling Kg Total Life Cycle : 0.00967
    • Materials For Recycling Kg Manufacturing A1 A3 : 0
    • Materials For Recycling Kg Distribution A4 : 0
    • Materials For Recycling Kg Installation A5 : 0.0053384722
    • Materials For Recycling Kg Maintenance B2 : 0
    • Materials For Recycling Kg Repair B3 : 0
    • Materials For Recycling Kg Replacement B4 : 0
    • Materials For Recycling Kg Operational Energy Use B6 : 0
    • Materials For Recycling Kg End Of Life C1 C4 : 0.0043315278
    • Materials For Recycling Kg Benefits Loads Beyond System Boundaries D : 0
    • Net Use Of Fresh Water M3 Total Life Cycle : 0.0948239785
    • Net Use Of Fresh Water M3 Manufacturing A1 A3 : 0.0004307639
    • Net Use Of Fresh Water M3 Distribution A4 : 0.0000002887
    • Net Use Of Fresh Water M3 Installation A5 : 0.0000965833
    • Net Use Of Fresh Water M3 Maintenance B2 : 0
    • Net Use Of Fresh Water M3 Repair B3 : 0
    • Net Use Of Fresh Water M3 Replacement B4 : 0
    • Net Use Of Fresh Water M3 Operational Energy Use B6 : 0.0883785648
    • Net Use Of Fresh Water M3 End Of Life C1 C4 : 0.0059177778
    • Net Use Of Fresh Water M3 Benefits Loads Beyond System Boundaries D : -0.0003922778
    • Non Hazardous Waste Disposed Of Kg Total Life Cycle : 15.7582368264
    • Non Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 0.256125
    • Non Hazardous Waste Disposed Of Kg Distribution A4 : 0.0001146042
    • Non Hazardous Waste Disposed Of Kg Installation A5 : 0.0316027778
    • Non Hazardous Waste Disposed Of Kg Maintenance B2 : 0
    • Non Hazardous Waste Disposed Of Kg Repair B3 : 0
    • Non Hazardous Waste Disposed Of Kg Replacement B4 : 0
    • Non Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 15.4604722222
    • Non Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.0099222222
    • Non Hazardous Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -0.1402291667
    • Ozone Depletion Kg Equivalent Cfc 11 Total Life Cycle : 0.0000005017
    • Ozone Depletion Kg Equivalent Cfc 11 Manufacturing A1 A3 : 0.0000000386
    • Ozone Depletion Kg Equivalent Cfc 11 Distribution A4 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Installation A5 : 0.0000000006
    • Ozone Depletion Kg Equivalent Cfc 11 Maintenance B2 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Repair B3 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Replacement B4 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Operational Energy Use B6 : 0.0000004623
    • Ozone Depletion Kg Equivalent Cfc 11 End Of Life C1 C4 : 0.0000000002
    • Ozone Depletion Kg Equivalent Cfc 11 Benefits Loads Beyond System Boundaries D : -0.0000000042
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Total Life Cycle : 0.2279667421
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Manufacturing A1 A3 : 0.0008286806
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Distribution A4 : 0.0000273681
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Installation A5 : 0.0000205812
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Maintenance B2 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Repair B3 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Replacement B4 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Operational Energy Use B6 : 0.2270472685
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv End Of Life C1 C4 : 0.0000428437
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Benefits Loads Beyond System Boundaries D : -0.0000879097
    • Radioactive Waste Disposed Of Kg Total Life Cycle : 0.0025027385
    • Radioactive Waste Disposed Of Kg Manufacturing A1 A3 : 0.0000779722
    • Radioactive Waste Disposed Of Kg Distribution A4 : 0.0000000816
    • Radioactive Waste Disposed Of Kg Installation A5 : 0.000004242
    • Radioactive Waste Disposed Of Kg Maintenance B2 : 0
    • Radioactive Waste Disposed Of Kg Repair B3 : 0
    • Radioactive Waste Disposed Of Kg Replacement B4 : 0
    • Radioactive Waste Disposed Of Kg Operational Energy Use B6 : 0.002419994
    • Radioactive Waste Disposed Of Kg End Of Life C1 C4 : 0.0000004486
    • Radioactive Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -0.0000153819
    • Terrestrial Eutrophication Mole Of N Equiv Total Life Cycle : 0.9435925162
    • Terrestrial Eutrophication Mole Of N Equiv Manufacturing A1 A3 : 0.0024667361
    • Terrestrial Eutrophication Mole Of N Equiv Distribution A4 : 0.0001083403
    • Terrestrial Eutrophication Mole Of N Equiv Installation A5 : 0.0000770764
    • Terrestrial Eutrophication Mole Of N Equiv Maintenance B2 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Repair B3 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Replacement B4 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Operational Energy Use B6 : 0.9408064815
    • Terrestrial Eutrophication Mole Of N Equiv End Of Life C1 C4 : 0.0001338819
    • Terrestrial Eutrophication Mole Of N Equiv Benefits Loads Beyond System Boundaries D : -0.0002768403
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj TLC : 2163.829419213
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Mfg A1 A3 : 2.9554861111
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Dist A4 : 0.0455465278
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Inst A5 : 0.1011180556
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Maint B2 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Repair B3 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Replament B4 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj OpEnergy B6 : 2159.7851851852
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj EoL C1 C4 : 0.9420833333
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj BLB SysBound D : -0.6770625
    • Total Use Of Primary Energy During The Life Cycle Mj Total Life Cycle : 2551.9773847222
    • Total Use Of Primary Energy During The Life Cycle Mj Manufacturing A1 A3 : 3.0552083333
    • Total Use Of Primary Energy During The Life Cycle Mj Distribution A4 : 0.0456069444
    • Total Use Of Primary Energy During The Life Cycle Mj Installation A5 : 0.108375
    • Total Use Of Primary Energy During The Life Cycle Mj Maintenance B2 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Repair B3 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Replacement B4 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Operational Energy Use B6 : 2547.825
    • Total Use Of Primary Energy During The Life Cycle Mj End Of Life C1 C4 : 0.9431944444
    • Total Use Of PrE During The Life Cycle Mj BLB SysBound D : -0.7148611111
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj TLC : 388.1033066356
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Mfg A1 A3 : 0.0997708333
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Dist A4 : 0.0000607792
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Inst A5 : 0.0072555556
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Maint B2 : 0
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Repair B3 : 0
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Replament B4 : 0
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj OpEnergy B6 : 387.9950925926
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj EoL C1 C4 : 0.001126875
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj BLB SysBound D : -0.0377805556
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 0.3713472222
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.3713472222
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of NRE PrE Resources Used As RawMats Mj OpEnergy B6 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of NRE PrE Resources Used As RawMats Mj BLB SysBound D : 0
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj TLC : 2163.4580303241
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Mfg A1 A3 : 2.5840972222
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Dist A4 : 0.0455465278
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Inst A5 : 0.1011180556
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Maint B2 : 0
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Repair B3 : 0
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Replacement B4 : 0
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj OpEnergy B6 : 2159.7851851852
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj EoL C1 C4 : 0.9420833333
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj BLB SysBound D : -0.6770625
    • Use Of Non Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Non Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Non Renewable Secondary Fuels Mj Maintenance B2 : 0
    • Use Of Non Renewable Secondary Fuels Mj Repair B3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Replacement B4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Benefits Loads Beyond System Boundaries D : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 0.1058888889
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.1058888889
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of RE PrE Resources Used As RawMats Mj OpEnergy B6 : 0
    • Use Of RE PrE Resources Used As RawMats Mj BLB SysBound D : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : -0.0826388889
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj TLC : 387.9974114273
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Mfg A1 A3 : -0.006124375
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Dist A4 : 0.0000607792
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Inst A5 : 0.0072555556
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Maint B2 : 0
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Repair B3 : 0
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Replacement B4 : 0
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj OpEnergy B6 : 387.9950925926
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj EoL C1 C4 : 0.001126875
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj BLB SysBound D : 0.0448597222
    • Use Of Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Renewable Secondary Fuels Mj Maintenance B2 : 0
    • Use Of Renewable Secondary Fuels Mj Repair B3 : 0
    • Use Of Renewable Secondary Fuels Mj Replacement B4 : 0
    • Use Of Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Renewable Secondary Fuels Mj Benefits Loads Beyond System Boundaries D : 0
    • Use Of Secondary Materials Kg Total Life Cycle : 0.0000158
    • Use Of Secondary Materials Kg Manufacturing A1 A3 : 0.0000158
    • Use Of Secondary Materials Kg Distribution A4 : 0
    • Use Of Secondary Materials Kg Installation A5 : 0
    • Use Of Secondary Materials Kg Maintenance B2 : 0
    • Use Of Secondary Materials Kg Repair B3 : 0
    • Use Of Secondary Materials Kg Replacement B4 : 0
    • Use Of Secondary Materials Kg Operational Energy Use B6 : 0
    • Use Of Secondary Materials Kg End Of Life C1 C4 : 0
    • Use Of Secondary Materials Kg Benefits Loads Beyond System Boundaries D : 0
  • Important Information Attributes
    • Persona Type Ids : BM9, EU, LC, OM, OM8, PB, SC, SI, VR
    • Persona Type Names : Charge Point Operator, End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician, System Integrator, IT Channel Partner
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Customizable : no, 0
    • Electromagnetic Compatibility : electrostatic discharge - test level: 6 kV (on contact (on metal parts)) conforming to IEC 61000-4-2, electrostatic discharge - test level: 6 kV (on contact (on metal parts)) conforming to IEC 61000-4-2, electrostatic discharge - test level: 6 kV (on contact (on metal parts)) conforming to IEC 61000-4-2, electrostatic discharge - test level: 6 kV (on contact (on metal parts)) conforming to IEC 61000-4-2, electrostatic discharge - test level: 8 kV (in free air (in insulating parts)) conforming to IEC 61000-4-2, electrostatic discharge - test level: 8 kV (in free air (in insulating parts)) conforming to IEC 61000-4-2, electrostatic discharge - test level: 8 kV (in free air (in insulating parts)) conforming to IEC 61000-4-2, electrostatic discharge - test level: 8 kV (in free air (in insulating parts)) conforming to IEC 61000-4-2, electromagnetic emission class B conforming to IEC 55011, electromagnetic emission class B conforming to IEC 55011, electromagnetic emission class B conforming to IEC 55011
    • Electromagnetic Emission : class B IEC 55011, class B IEC 55011
    • Overvoltage Category : class II conforming to IEC 60536, class II conforming to IEC 60536
    • Resistance To Electromagnetic Fields : 10 V/m IEC 61000-4-3, 10 V/m IEC 61000-4-3
    • Resistance To Electrostatic Discharge : 6 kV on contact (on metal parts) IEC 61000-4-2, 6 kV on contact (on metal parts) IEC 61000-4-2, 6 kV on contact (on metal parts) IEC 61000-4-2, 8 kV in free air (in insulating parts) IEC 61000-4-2, 8 kV in free air (in insulating parts) IEC 61000-4-2, 8 kV in free air (in insulating parts) IEC 61000-4-2
    • Resistance To Fast Transients : 2 kV IEC 61000-4-4, 2 kV IEC 61000-4-4
    • Resistance To High Pressure Washer : 7000000 Pa 55 °C 0.1 m, 7000000 Pa 55 °C 0.1 m, 7000000 Pa 55 °C 0.1 m
    • Service Life : 100000 h at rated voltage and 25 °C, 100000 h at rated voltage and 25 °C
    • Shock Resistance : 50 gn 18 ms) half sine wave acceleration IEC 60068-2-27, 50 gn 18 ms) half sine wave acceleration IEC 60068-2-27, 50 gn 18 ms) half sine wave acceleration IEC 60068-2-27, 50 gn 18 ms) half sine wave acceleration IEC 60068-2-27, 30 gn 11 ms) half sine wave acceleration IEC 60068-2-27, 30 gn 11 ms) half sine wave acceleration IEC 60068-2-27, 30 gn 11 ms) half sine wave acceleration IEC 60068-2-27, 30 gn 11 ms) half sine wave acceleration IEC 60068-2-27
    • Supply Voltage Limits : 195-264 V AC, 195-264 V AC
    • Vibration Resistance : 5 gn (f= 12-500 Hz) conforming to IEC 60068-2-6, 5 gn (f= 12-500 Hz) conforming to IEC 60068-2-6, 5 gn (f= 12-500 Hz) conforming to IEC 60068-2-6
    • Connections Terminals : screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1, screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1, screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1, screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1, screw clamp terminals, 1 x 0.22...2 x 2.5 mm² without cable end IEC 60947-1, screw clamp terminals, 1 x 0.22...2 x 2.5 mm² without cable end IEC 60947-1, screw clamp terminals, 1 x 0.22...2 x 2.5 mm² without cable end IEC 60947-1, screw clamp terminals, 1 x 0.22...2 x 2.5 mm² without cable end IEC 60947-1
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-25
    • Legacy WEEE Scope : Out
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2308027EN
    • Product Repair Index Dam Doc : XB4BS8442-ENVREPAIR-A-EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : No
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS EUR Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : Yes
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Bezel Material : dark grey plastic
    • Bulb Base : integral LED
    • Compatibility Code : XB5
    • Device Short Name : XB5
    • Fixing Collar Material : plastic
    • Head Type : standard
    • Important Message : A change in appearance may be noted on the product but does not affect its use in terms of function and safety. This makes it compatible with our Universal LED blocks
    • Mounting Diameter : 22.5 mm
    • Package Weight Lbs : 25.000 g
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : monolithic pilot light
    • Product Repair Index : A
    • Range Of Product : Harmony XB5
    • Returnability : Yes
    • Shape Of Signaling Unit Head : round
    • Signalling Type : steady
    • Sustainable Packaging : Yes
    • Terminals Description ISO N 1 : (X1-X2)PL
    • Total Lifecycle Carbon Footprint : 102 kg CO2 eq.
    • Relationship Type : Compatible relationship
    • Product Repair Index Dam Document Id : XB4BS8442-ENVREPAIR-A-EN
    • Pep Code : ENVPEP2308027EN
    • Pep Verification Date : 2023-08-01
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : Pilot light uses an integral LED and screw clamp terminals. This pilot light, designed to last without maintenance for a bright indication of process and machine operations, is easily installed into standard 22mm diameter cut-outs and connected with simple screw-clamp connections. It is clearly distinguishable visually at a distance thanks to a bright and long lasting LED illumination.This pushbutton&nbsp;power consumption is 0.432W with 71% active mode for 10 years, and it product&nbsp;complies with IEC 60947-1 standards..
    • Functional Unit Unit : Unit
    • Product Kit Identifier : N
    • Huella De Carbono De La Fase De Distribución A4 : 0 kg CO2 eq.
    • Huella De Carbono De La Fase De Fabricación A1 A A3 : 0.2 kg CO2 eq.
    • Huella De Carbono De La Fase De Fin De Vida C1 A C4 : 0 kg CO2 eq.
    • Huella De Carbono De La Fase De Instalación A5 : 0 kg CO2 eq.
    • Huella De Carbono De La Fase De Uso B2 B3 B4 B6 : 102 kg CO2 eq.
  • Environment Attributes Main
    • EU ROHS Directive : Compliant By Exemption​, Pro-active compliance (Product out of EU RoHS legal scope)
    • IP Degree Of Protection : IP66 IEC 60529, IP66 IEC 60529, IP67 IEC 60529, IP67 IEC 60529, IP69 IEC 60529, IP69 IEC 60529, IP69K ISO 20653, IP69K ISO 20653
    • Nema Degree Of Protection : NEMA 13, NEMA 4X
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 102.1094187037
    • Circularity Profile : ENVEOLI2308027EN
    • Environmental Disclosure : ENVPEP2308027EN
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2308027EN
    • Pep Verification Date : 2023-08-01
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : monolithic pilot light
    • Range Of Product : Harmony XB5
  • Surge Protection And Filtering Attributes
    • Surge Withstand : 1 kV IEC 61000-4-5, 1 kV IEC 61000-4-5
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Overview Attributes
    • Device Presentation : monolithic product