NEMA Contactor, Type S, nonreversing, Size 3, 90A, 1 phase, up to 100 kA, 2 pole, 120 VAC coil, open

NEMA Contactor, Type S, nonreversing, Size 3, 90A, 1 phase, up to 100 kA, 2 pole, 120 VAC coil, open

SQD8502SEO1V02S 8502SEO1V02S 785901790730
1217.22 / EACH
  • Certifications: CSA, UL Listed File E78351 CCN NLDX
  • Contact Configuration: Without
  • Depth: 165.1 mm
  • Height: 180.09 mm
  • Line Rated Current: 90 A
  • NEMA: 3
  • Number of Phases: 1
  • Warranty Length: 18 mth
  • Width: 138.94 mm
Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 2 pole NEMA Size 3 non-reversing contactor has a 90 ampere rating. Single phase NEMA Size 3 contactors have no horsepower ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a 110/120 VAC 50/60 Hz coil that is wired for separate control. This NEMA contactor is an open device without an enclosure. This contactor is 7.09 inches tall, 5.47 inches wide and 6.50 inches deep. A wide variety of accessories are available for Type S contactors. Type S NEMA contactors are UL listed and CSA certified.
  • Product Description
  • Specifications
Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 2 pole NEMA Size 3 non-reversing contactor has a 90 ampere rating. Single phase NEMA Size 3 contactors have no horsepower ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a 110/120 VAC 50/60 Hz coil that is wired for separate control. This NEMA contactor is an open device without an enclosure. This contactor is 7.09 inches tall, 5.47 inches wide and 6.50 inches deep. A wide variety of accessories are available for Type S contactors. Type S NEMA contactors are UL listed and CSA certified.
  • Rated Power In Hp : not rated
  • [Uc] Control Circuit Voltage : 120 V AC 60 Hz || 110 V AC 50 Hz
  • Nema Degree Of Protection : not rated (open device)
  • Contactor Application : non-reversing
  • Control Type : no control units
  • Local Signalling : no indicator
  • Warranty : 18 months
  • Poles Description : 2P
  • Product Compatibility : circuit-breaker 150 A maximum, SCCR: 100 kA at 480 V AC || fuse J 200 A maximum, SCCR: 100 kA at 600 V AC || fuse T 200 A maximum, SCCR: 100 kA at 600 V AC || fuse RK1 200 A maximum, SCCR: 100 kA at 600 V AC || fuse RK5 200 A maximum, SCCR: 100 kA at 600 V AC
  • Electrical Connection : screw clamp terminals
  • Product Certifications : UL listed file E78351 CCN NLDX || CSA
  • Auxiliary Contact Composition : without
  • Phase : 1 phase
  • Maximum Height : 180.09 mm
  • Maximum Depth : 165.1 mm
  • Range Of Product : 8502S
  • Nema Size : 3
  • Product Or Component Type : contactor
  • Provided Equipment : fuse not supplied
  • [Ue] Rated Operational Voltage : 600 V AC
  • Maximum Width : 138.94 mm
  • Line Rated Current : 90 A
  • Control Circuit : separate control circuit